Feasibility and safety of parietal pleural cryobiopsy during semi-rigid thoracoscopy

被引:33
作者
Rozman, Ales [1 ]
Camlek, Luka [2 ]
Malovrh, Mateja Marc [3 ]
Kern, Izidor [4 ]
Schoenfeld, Nicolas [5 ]
机构
[1] Univ Clin Pulm & Allerg Dis Golnik, Endoscopy Pulmonol Dept, Golnik 36, Golnik 4204, Slovenia
[2] Univ Clin Pulm & Allerg Dis Golnik, Intens Care Unit, Golnik, Slovenia
[3] Univ Clin Pulm & Allerg Dis Golnik, Dept Intervent Pulmonol, Golnik, Slovenia
[4] Univ Clin Pulm & Allerg Dis Golnik, Dept Pathol, Golnik, Slovenia
[5] HELIOS Klinikum Emil von Behring GmbH, Oberarzt Klin Pneumol, Lungenklin Heckeshorn, Berlin, Germany
关键词
cryobiopsy; flex-rigid pleuroscopy; pleural biopsy; safety; thoracoscopy; DIAGNOSTIC YIELD; LUNG-CANCER; BIOPSY; PLEUROSCOPY; CRYOTHERAPY; BRONCHOSCOPY; CRYOSURGERY; OBSTRUCTION; MANAGEMENT; CRYOPROBES;
D O I
10.1111/crj.12256
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background and AimsPerforming pleural biopsies during semi-rigid thoracoscopy is sometimes a difficult and time-consuming task because of the lack of mechanical power of dedicated flexible forceps in patients with thickened pleura. The purpose of this first ever pilot study was to test the feasibility of taking biopsy specimens by cryoprobe from the parietal pleura during semi-rigid thoracoscopy. Our aim was also to assess the diagnostic value and quality of specimens obtained, morphological features, feasibility of immunohistochemistry staining and possibility of DNA isolation. The secondary aim was to evaluate safety, tolerability and duration of the procedure. MethodsFifteen patients with pleural effusion of unknown origin that underwent semi-rigid thoracoscopy were included. Biopsies were obtained using a flexible autoclavable cryoprobe 20416-032 (Erbokryo CA, ERBE, Tubingen, Germany) 2.4mm in diameter and a semi-rigid autoclavable Olympus LTF-160 (Olympus, Tokyo, Japan) thoracoscope. ResultsTissue samples were obtained from 14 patients (93.3%), three from each. Of the samples, 81% were easily interpretable and 19% were interpretable with some difficulty by the pathologist. The samples were of good quality, with the level of artifacts below 25%. The specimens were adequate for histological diagnosis, immunohistochemical staining and DNA isolation. There were no moderate or major bleeding problems after the biopsies; two patients experienced pain. The median duration of three cryobiopsies (per patient) was 4min (range 3-6min). ConclusionsCryobiopsy during semi-rigid thoracoscopy appears worth to be evaluated in a larger prospective multicenter trial as our preliminary data were promising for efficacy and safety.
引用
收藏
页码:574 / 578
页数:5
相关论文
共 27 条
  • [1] Endobronchial cryobiopsy or forceps biopsy for lung cancer diagnosis
    Aktas, Zafer
    Gunay, Ersin
    Hoca, Nevin Taci
    Yilmaz, Aydin
    Demirag, Funda
    Gunay, Sibel
    Sipit, Tugrul
    Kurt, Emine Bahar
    [J]. ANNALS OF THORACIC MEDICINE, 2010, 5 (04) : 242 - 246
  • [2] Cryosurgery for malignant endobronchial tumors - Analysis of outcome
    Asimakopoulos, G
    Beeson, J
    Evans, J
    Maiwand, MO
    [J]. CHEST, 2005, 127 (06) : 2007 - 2014
  • [3] Transbronchial Cryobiopsy: A New Tool for Lung Biopsies
    Babiak, Alexander
    Hetzel, Juergen
    Krishna, Ganesh
    Fritz, Peter
    Moeller, Peter
    Balli, Tahsin
    Hetzel, Martin
    [J]. RESPIRATION, 2009, 78 (02) : 203 - 208
  • [4] PLEURAL AND LUNG CRYOBIOPSIES DURING THORACOSCOPY
    BONNIOT, JPA
    HOMASSON, JPD
    RODEN, SL
    ANGEBAULT, ML
    RENAULT, PC
    [J]. CHEST, 1989, 95 (03) : 492 - 493
  • [5] Cryotherapy in early superficial bronchogenic carcinoma
    Deygas, N
    Froudarakis, M
    Ozenne, G
    Vergnon, JM
    [J]. CHEST, 2001, 120 (01) : 26 - 31
  • [6] A novel instrument for the evaluation of the pleural space - An experience in 34 patients
    Ernst, A
    Hersh, CP
    Herth, F
    Thurer, R
    LoCicero, J
    Beamis, J
    Mathur, P
    [J]. CHEST, 2002, 122 (05) : 1530 - 1534
  • [7] Prospective Controlled Animal Study on Biopsy Sampling with New Flexible Cryoprobes versus Forceps: Evaluation of Biopsy Size, Histological Quality and Bleeding Risk
    Franke, Karl-Josef
    Theegarten, Dirk
    von Weyhern, Claus Hann
    Nilius, Georg
    Brueckner, Christiane
    Hetzel, Juergen
    Hetzel, Martin
    Ruhle, Karl-Heinz
    Enderle, Markus D.
    Szyrach, Mara N. I.
    [J]. RESPIRATION, 2010, 80 (02) : 127 - 132
  • [8] Experimental Study on Biopsy Sampling Using New Flexible Cryoprobes: Influence of Activation Time, Probe Size, Tissue Consistency, and Contact Pressure of the Probe on the Size of the Biopsy Specimen
    Franke, Karl-Josef
    Szyrach, Mara
    Nilius, Georg
    Hetzel, Juergen
    Hetzel, Martin
    Ruehle, Karl-Heinz
    Enderle, Markus D.
    [J]. LUNG, 2009, 187 (04) : 253 - 259
  • [9] TRANSBRONCHOSCOPIC CRYOSURGERY OF RESPIRATORY STRUCTURES - EXPERIMENTAL AND CLINICAL STUDIES
    GORENSTEIN, A
    NEEL, HB
    SANDERSON, DR
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1976, 85 (05) : 670 - 678
  • [10] Morphometrical analysis of transbronchial cryobiopsies
    Griff, Sergej
    Ammenwerth, Wim
    Schoenfeld, Nicolas
    Bauer, Torsten T.
    Mairinger, Thomas
    Blum, Torsten-Gerriet
    Kollmeier, Jens
    Gruening, Wolfram
    [J]. DIAGNOSTIC PATHOLOGY, 2011, 6