Prevalence of venous obstruction in permanent endovenous pacing in newborns and infants: Follow-up

被引:11
作者
Stojanov, P
Vranes, M
Velimirovic, D
Zivkovic, M
Kocica, MJ
Davidovic, L
Neskovic, V
Stajevic, M
机构
[1] UC Clin Ctr Serbia, Inst Cardiovasc Dis, Pacemaker Ctr, YU-11000 Belgrade, Serbia Monteneg, Serbia
[2] Inst Cardiovasc Dis Dedinje, Belgrade, Serbia Monteneg, Serbia
[3] Inst Mother & Children Care, Belgrade, Serbia Monteneg, Serbia
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2005年 / 28卷 / 05期
关键词
venous obstruction; permanent endovenous pacing; newborns; infants;
D O I
10.1111/j.1540-8159.2005.09254.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: We examined the prevalence of venous obstruction in 12 newborns and infants with permanent endovenous ventricular pacing, clinically, and by ultrasonographic assessment of hemodynamics (spontaneity, phasicity, velocity, and turbulence of flow) and morphologic parameters (compressibility, wall thickness, and thrombus presence). Material and Methods: All implantations of single ventricular unipolor endovenous steroid leads, were performed via cephalic vein, and pacemakers were placed in subcutaneous pocket in right prepectoral region. After the vascular surgeon has carefully examined all children for presence of venous collaterals in the chest wall, morphologic and hemodynamic parameters of the subclavian, axillary, and internal jugular veins, were assessed by linear-array color Doppler. Lead capacity (LC) was calculated for each patient. Results: Mean age of patients at implant was 6.2 months (range 1 day-12 months), mean weight 6.5 kg (range 2.25-10 kg), and mean height 60.9 cm (range 48-78 cm). Mean LC was 1.99 (range 1.14-3.07). Total follow-up was 1023 and mean follow-up 85.2 pacing months (range 3-156). No clinical signs of venous obstruction were observed. Mild stenosis (20%) of subclavian vein was found by color Doppler in 2112 patients. Both had adequate lead diameter for body surface. Conclusion: Permanent endovenous pacing is a feasible procedure, even in children of body weight less than 10 kg, with quite acceptable impact on venous system potency.
引用
收藏
页码:361 / 365
页数:5
相关论文
共 13 条
[1]   SURFACE THROMBOSIS AND FIBROUS ENCAPSULATION OF INTRAVENOUS PACEMAKER CATHETER ELECTRODE [J].
BECKER, AE ;
BECKER, MJ ;
EDWARDS, JE ;
CLAUDON, DG .
CIRCULATION, 1972, 46 (02) :409-&
[2]   Risk factors for venous obstruction in children with transvenous pacing leads [J].
Figa, FH ;
McCrindle, BW ;
Bigras, JL ;
Hamilton, RM ;
Gow, RM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (08) :1902-1909
[3]   CARDIAC PATHOLOGY OF TRANSVENOUS PACEMAKERS IN DOGS [J].
FISHBEIN, MC ;
TAN, KS ;
BEAZELL, JW ;
SCHULMAN, JH ;
HIROSE, FM ;
CRILEY, JM .
AMERICAN HEART JOURNAL, 1977, 93 (01) :73-81
[4]   PEDIATRIC TRANSVENOUS PACING - A CONCERN FOR VENOUS THROMBOSIS [J].
GILLETTE, PC ;
ZEIGLER, V ;
BRADHAM, GB ;
KINSELLA, P .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11) :1935-1939
[5]  
GILLETTE PC, 1995, PAEDIAT CARDIAC PACI, P95
[6]   CARDIAC PATHOLOGY OF TRANSVENOUS PACEMAKERS [J].
HUANG, TY ;
BABA, N .
AMERICAN HEART JOURNAL, 1972, 83 (04) :469-&
[7]   IMPLANTATION OF TRANSVENOUS PACEMAKERS IN INFANTS AND SMALL CHILDREN [J].
MOLINA, JE ;
DUNNIGAN, AC ;
CROSSON, JE .
ANNALS OF THORACIC SURGERY, 1995, 59 (03) :689-694
[8]  
MOLLER M, 2000, PACE 2, V23, pS9
[9]   FATE OF PERMANENT INTRACARDIAC ELECTRODES [J].
PARSONNE.V ;
ZUCKER, IR ;
KANNERST.ML ;
GILBERT, L ;
ALVARES, JF .
JOURNAL OF SURGICAL RESEARCH, 1966, 6 (07) :285-&
[10]   AUTOPSY FINDINGS WITH PERMANENT PERVENOUS PACEMAKERS [J].
ROBBOY, SJ ;
HARTHORNE, JW ;
LEINBACH, RC ;
SANDERS, CA ;
AUSTEN, WG .
CIRCULATION, 1969, 39 (04) :495-+