Microdialysis SPR: diffusion-gated sensing in blood

被引:17
作者
Breault-Turcot, Julien [1 ]
Masson, Jean-Francois [1 ]
机构
[1] Univ Montreal, Dept Chem, Montreal, PQ H3C 3J7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
SURFACE-PLASMON RESONANCE; HUMAN SERUM-ALBUMIN; ON-A-CHIP; BIOMARKER DISCOVERY; LIGAND-BINDING; PROTEIN; STRATEGIES; BIOSENSORS; CHEMISTRY; PLATELETS;
D O I
10.1039/c5sc00716j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Chemical measurements are rarely performed in crude blood due to the poor performance of sensors and devices exposed to biofluids. In particular, biosensors have been severely limited for detection in whole blood due to surface fouling from proteins, the interaction of cells with the sensor surface and potential optical interference when considering optical methods of analysis. To solve this problem, a dialysis chamber was introduced to a surface plasmon resonance (SPR) biosensor to create a diffusion gate for large molecules. This dialysis chamber relies on the faster migration of small molecules through a microporous membrane towards a sensor, located at a specified distance from the membrane. Size filtering and diffusion through a microporous membrane restricted the access of blood cells and larger biomolecules to a sensing chamber, while smaller, faster diffusing biomolecules migrated preferentially to the sensor with limited interference from blood and serum. The affinity of a small peptide (DBG178) with anti-atherosclerotic activity and targeting type B scavenger receptor CD36 was successfully monitored at micromolar concentrations in human serum and blood without any pre-treatment of the sample. This concept could be generally applied to a variety of targets for biomolecular interaction monitoring and quantification directly in whole blood, and could find potential applications in biochemical assays, pharmacokinetic drug studies, disease treatment monitoring, implantable plasmonic sensors, and point-of-care diagnostics.
引用
收藏
页码:4247 / 4254
页数:8
相关论文
共 38 条
[1]  
AARTS PAMM, 1983, BLOOD, V62, P214
[2]   Biosensors for in vivo glucose measurement: can we cross the experimental stage [J].
Abel, PU ;
von Woedtke, T .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) :1059-1070
[3]   The human plasma proteome - History, character, and diagnostic prospects [J].
Anderson, NL ;
Anderson, NG .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (11) :845-867
[4]   Microfiltration platform for continuous blood plasma protein extraction from whole blood during cardiac surgery [J].
Aran, Kiana ;
Fok, Alex ;
Sasso, Lawrence A. ;
Kamdar, Neal ;
Guan, Yulong ;
Sun, Qi ;
Uendar, Akif ;
Zahn, Jeffrey D. .
LAB ON A CHIP, 2011, 11 (17) :2858-2868
[5]   Coronary heart disease prevention: Nutrients, foods, and dietary patterns [J].
Bhupathiraju, Shilpa N. ;
Tucker, Katherine L. .
CLINICA CHIMICA ACTA, 2011, 412 (17-18) :1493-1514
[6]   Comparison of different depletion strategies for improved resolution in proteomic analysis of human serum samples [J].
Björhall, K ;
Miliotis, T ;
Davidsson, P .
PROTEOMICS, 2005, 5 (01) :307-317
[7]   Surface chemistry to minimize fouling from blood-based fluids [J].
Blaszykowski, Christophe ;
Sheikh, Sonia ;
Thompson, Michael .
CHEMICAL SOCIETY REVIEWS, 2012, 41 (17) :5599-5612
[8]   CD36 mediates the cardiovascular action of growth hormone-releasing peptides in the heart [J].
Bodart, V ;
Febbraio, M ;
Demers, A ;
McNicoll, N ;
Pohankova, P ;
Perreault, A ;
Sejlitz, T ;
Escher, E ;
Silverstein, RL ;
Lamontagne, D ;
Ong, H .
CIRCULATION RESEARCH, 2002, 90 (08) :844-849
[9]   Modified peptide monolayer binding His-tagged biomolecules for small ligand screening with SPR biosensors [J].
Bolduc, Olivier R. ;
Lambert-Lanteigne, Patrick ;
Colin, Damien Y. ;
Zhao, Sandy Shuo ;
Proulx, Caroline ;
Boeglin, Damien ;
Lubell, William D. ;
Pelletier, Joelle N. ;
Fethiere, James ;
Ong, Huy ;
Masson, Jean-Francois .
ANALYST, 2011, 136 (15) :3142-3148
[10]   Blood plasma separation microfluidic chip with gradual filtration [J].
Chen, Jingdong ;
Chen, Di ;
Yuan, Tao ;
Chen, Xiang ;
Xie, Yao ;
Fu, Hualin ;
Cui, Daxiang ;
Fan, Xudong ;
Oo, Maung Kyaw Khaing .
MICROELECTRONIC ENGINEERING, 2014, 128 :36-41