Pulse Oximetry in Pediatric Practice

被引:143
作者
Fouzas, Sotirios [1 ]
Priftis, Kostas N. [2 ]
Anthracopoulos, Michael B. [1 ]
机构
[1] Univ Hosp Patras, Resp Unit, Dept Pediat, Patras 26504, Greece
[2] Univ Athens, Sch Med, Dept Pediat 3, Attikon Hosp, GR-11527 Athens, Greece
关键词
pulse oximetry; children; hemoglobin oxygen saturation; LENGTH-OF-STAY; ARTERIAL OXYGEN-SATURATION; CONGENITAL HEART-DISEASE; HEALTHY-CHILDREN; REFERENCE VALUES; CARDIOPULMONARY-RESUSCITATION; CLINICAL-ASSESSMENT; PRETERM INFANTS; RESPONSE-TIME; DELIVERY ROOM;
D O I
10.1542/peds.2011-0271
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The introduction of pulse oximetry in clinical practice has allowed for simple, noninvasive, and reasonably accurate estimation of arterial oxygen saturation. Pulse oximetry is routinely used in the emergency department, the pediatric ward, and in pediatric intensive and perioperative care. However, clinically relevant principles and inherent limitations of the method are not always well understood by health care professionals caring for children. The calculation of the percentage of arterial oxyhemoglobin is based on the distinct characteristics of light absorption in the red and infrared spectra by oxygenated versus deoxygenated hemoglobin and takes advantage of the variation in light absorption caused by the pulsatility of arterial blood. Computation of oxygen saturation is achieved with the use of calibration algorithms. Safe use of pulse oximetry requires knowledge of its limitations, which include motion artifacts, poor perfusion at the site of measurement, irregular rhythms, ambient light or electromagnetic interference, skin pigmentation, nail polish, calibration assumptions, probe positioning, time lag in detecting hypoxic events, venous pulsation, intravenous dyes, and presence of abnormal hemoglobin molecules. In this review we describe the physiologic principles and limitations of pulse oximetry, discuss normal values, and highlight its importance in common pediatric diseases, in which the principle mechanism of hypoxemia is ventilation/perfusion mismatch (eg, asthma exacerbation, acute bronchiolitis, pneumonia) versus hypoventilation (eg, laryngotracheitis, vocal cord dysfunction, foreign-body aspiration in the larynx or trachea). Additional technologic advancements in pulse oximetry and its incorporation into evidence-based clinical algorithms will improve the efficiency of the method in daily pediatric practice. Pediatrics 2011;128:740-752
引用
收藏
页码:740 / 752
页数:13
相关论文
共 50 条
  • [31] INVITRO INVESTIGATION OF THE FACTORS AFFECTING PULSE OXIMETRY
    DEKOCK, JP
    TARASSENKO, L
    JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (01): : 61 - 66
  • [32] Pulse oximetry monitoring for the evaluation of swallowing function
    Higo, R
    Tayama, N
    Watanabe, T
    Nito, T
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2003, 260 (03) : 124 - 127
  • [33] It Is Time for Routine Neonatal Screening by Pulse Oximetry
    Hoffman, Julien I. E.
    NEONATOLOGY, 2011, 99 (01) : 1 - 9
  • [34] Reference values for pulse oximetry at high altitude
    Gamponia, MJ
    Babaali, H
    Yugar, F
    Gilman, RH
    ARCHIVES OF DISEASE IN CHILDHOOD, 1998, 78 (05) : 461 - 465
  • [35] From PediHeart: Routine Pulse Oximetry for Neonates
    Francis McCaffrey
    Pediatric Cardiology, 2000, 21 (3) : 227 - 227
  • [36] Reliability of pulse oximetry in hypoxic newborn pigs
    Solevag, Anne Lee
    Dannevig, Ingrid
    Saltyte-Benth, Jurate
    Saugstad, Ola D.
    Nakstad, Britt
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2014, 27 (08) : 833 - 838
  • [37] Accuracy of fetal pulse oximetry and pitfalls in measurements
    Nijland, R
    Jongsma, HW
    Nijhuis, JG
    Oeseburg, B
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1997, 72 : S21 - S27
  • [38] PULSE OXIMETRY AS A SCREENING TEST FOR CRITICAL CONGENITAL HEART DISEASE IN TERM NEWBORNS
    Gomez-Rodriguez, Guadalupe
    Quezada-Herrera, Anai
    Amador-Licona, Norma
    Carballo-Magdaleno, Deyanira
    Jesus Rodriguez-Mejia, Evaldo
    Manuel Guizar-Mendoza, Juan
    REVISTA DE INVESTIGACION CLINICA-CLINICAL AND TRANSLATIONAL INVESTIGATION, 2015, 67 (02): : 130 - 134
  • [39] Feasibility of pulse oximetry for assessment of infants born in community based midwifery care
    Smit, Marrit
    Ganzeboom, Angelina
    Dawson, Jennifer A.
    Walther, Frans J.
    Bustraan, Jacqueline
    van Roosmalen, Jos J. M.
    te Pas, Arjan B.
    MIDWIFERY, 2014, 30 (05) : 539 - 543
  • [40] Use of Pulse Oximetry during Resuscitation of 230 Newborns-A Video Analysis
    Kolstad, Vilde
    Pike, Hanne
    Eilevstjonn, Joar
    Buskov, Frederikke
    Ersdal, Hege
    Rettedal, Siren
    CHILDREN-BASEL, 2023, 10 (07):