Fetal magnetocardiography measurements with an array of microfabricated optically pumped magnetometers

被引:147
作者
Alem, Orang [1 ,2 ]
Sander, Tilmann H. [3 ]
Mhaskar, Rahul [1 ,2 ]
LeBlanc, John [4 ]
Eswaran, Hari [5 ]
Steinhoff, Uwe [3 ]
Okada, Yoshio [6 ]
Kitching, John [1 ]
Trahms, Lutz [3 ]
Knappe, Svenja [1 ,2 ]
机构
[1] Natl Inst Stand & Technol, Boulder, CO 80305 USA
[2] Univ Colorado, Boulder, CO 80309 USA
[3] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
[4] Charles S Draper Labs, Cambridge, MA 02139 USA
[5] Univ Arkansas Med Sci, Little Rock, AR 72205 USA
[6] Boston Childrens Hosp, Boston, MA 02115 USA
关键词
atomic magnetometer; biomagnetism; fetal magnetocardiography; orthogonal projection; independent component analysis; microfabricated; ATOMIC MAGNETOMETER; MAGNETOENCEPHALOGRAPHY; COMPACT; SYSTEM; MCG;
D O I
10.1088/0031-9155/60/12/4797
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Following the rapid progress in the development of optically pumped magnetometer (OPM) technology for the measurement of magnetic fields in the femtotesla range, a successful assembly of individual sensors into an array of nearly identical sensors is within reach. Here, 25 microfabricated OPMs with footprints of 1 cm(3) were assembled into a conformal array. The individual sensors were inserted into three flexible belt-shaped holders and connected to their respective light sources and electronics, which reside outside a magnetically shielded room, through long optical and electrical cables. With this setup the fetal magnetocardiogram of a pregnant woman was measured by placing two sensor belts over her abdomen and one belt over her chest. The fetal magnetocardiogram recorded over the abdomen is usually dominated by contributions from the maternal magnetocardiogram, since the maternal heart generates a much stronger signal than the fetal heart. Therefore, signal processing methods have to be applied to obtain the pure fetal magnetocardiogram: orthogonal projection and independent component analysis. The resulting spatial distributions of fetal cardiac activity are in good agreement with each other. In a further exemplary step, the fetal heart rate was extracted from the fetal magnetocardiogram. Its variability suggests fetal activity. We conclude that microfabricated optically pumped magnetometers operating at room temperature are capable of complementing or in the future even replacing superconducting sensors for fetal magnetocardiography measurements.
引用
收藏
页码:4797 / 4811
页数:15
相关论文
共 48 条
[1]   High-sensitivity atomic magnetometer unaffected by spin-exchange relaxation [J].
Allred, JC ;
Lyman, RN ;
Kornack, TW ;
Romalis, MV .
PHYSICAL REVIEW LETTERS, 2002, 89 (13) :130801-130801
[2]   Cesium coherent population trapping magnetometer for cardiosignal detection in an unshielded environment [J].
Belfi, J. ;
Bevilacqua, G. ;
Biancalana, V. ;
Cartaleva, S. ;
Dancheva, Y. ;
Moi, L. .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2007, 24 (09) :2357-2362
[3]   A blind source separation technique using second-order statistics [J].
Belouchrani, A ;
AbedMeraim, K ;
Cardoso, JF ;
Moulines, E .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1997, 45 (02) :434-444
[4]   A laser-pumped magnetometer for the mapping of human cardiomagnetic fields [J].
Bison, G ;
Wynands, R ;
Weis, A .
APPLIED PHYSICS B-LASERS AND OPTICS, 2003, 76 (03) :325-328
[5]   A room temperature 19-channel magnetic field mapping device for cardiac signals [J].
Bison, G. ;
Castagna, N. ;
Hofer, A. ;
Knowles, P. ;
Schenker, J. -L. ;
Kasprzak, M. ;
Saudan, H. ;
Weis, A. .
APPLIED PHYSICS LETTERS, 2009, 95 (17)
[6]  
Bork J., 2001, BIOMAG2000, P970
[7]   Fetal magnetocardiographic mapping using independent component analysis [J].
Comani, S ;
Mantini, D ;
Alleva, G ;
Di Luzio, S ;
Romani, GL .
PHYSIOLOGICAL MEASUREMENT, 2004, 25 (06) :1459-1472
[8]   DETECTION OF VERY WEAK MAGNETIC FIELDS (10-9GAUSS) BY 87RB-ZERO-FIELD LEVEL CROSSING RESONANCES [J].
DUPONTRO.J ;
HAROCHE, S ;
COHENTAN.C .
PHYSICS LETTERS A, 1969, A 28 (09) :638-&
[9]   Clinical application of magnetocardiography [J].
Fenici, R ;
Brisinda, D ;
Meloni, AM .
EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2005, 5 (03) :291-313
[10]   Recommended standards for fetal magnetocardiography [J].
Grimm, B ;
Haueisen, J ;
Huotilainen, M ;
Lange, S ;
Van Leeuwen, P ;
Menendez, T ;
Peters, MJ ;
Schleussner, E ;
Schneider, U .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (11) :2121-2126