High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience

被引:47
作者
Beeres, Martin [1 ]
Schell, Boris [1 ]
Mastragelopoulos, Aristidis [1 ]
Herrmann, Eva [2 ]
Kerl, Josef Matthias [1 ]
Gruber-Rouh, Tatjana [1 ]
Lee, Clara [1 ]
Siebenhandl, Petra [1 ]
Bodelle, Boris [1 ]
Zangos, Stephan [1 ]
Vogl, Thomas J. [1 ]
Jacobi, Volkmar [1 ]
Bauer, Ralf W. [1 ]
机构
[1] Clin Goethe Univ, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Clin Goethe Univ, Dept Biostat, D-60590 Frankfurt, Germany
关键词
CT angiography; Aorta; High-pitch; Dual-source CT; Radiation dose; Motion artefacts; LIVER;
D O I
10.1007/s00330-011-2257-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To investigate the feasibility, image quality and radiation dose for high-pitch dual-source CT angiography (CTA) of the whole aorta without ECG synchronisation. Each group of 40 patients underwent CTA either on a 16-slice (group 1) or dual-source CT device with conventional single-source (group 2) or high-pitch mode with a pitch of 3.0 (group 3). The presence of motion or stair-step artefacts of the thoracic aorta was independently assessed by two readers. Subjective and objective scoring of motion and artefacts were significantly reduced in the high-pitch examination protocol (p < 0.05). The imaging length was not significantly different, but the imaging time was significantly (p < 0.001) shorter in the high-pitch group (12.2 vs. 7.4 vs. 1.7 s for groups 1, 2 and 3). The ascending aorta and the coronary ostia were reliably evaluable in all patients of group 3 without motion artefacts as well. High-pitch dual-source CT angiography of the whole aorta is feasible in unselected patients. As a significant advantage over regular pitch protocols, motion-free imaging of the aorta is possible without ECG synchronisation. Thus, this CT mode bears potential to become a standard CT protocol before trans-catheter aortic valve implantation (TAVI). aEuro cent High-pitch CT angiography without ECG synchronisation can provide motion-free aortic imaging aEuro cent High-pitch CTA could become the standard protocol before trans-catheter aortic valve implantation aEuro cent Without ECG-gating, there is no need for special preparation of the patient.
引用
收藏
页码:129 / 137
页数:9
相关论文
共 16 条
[1]   Thoracic Aorta: Prospective Electrocardiographically Triggered CT Angiography with Dual-Source CT-Feasibility, Image Quality, and Dose Reduction [J].
Blanke, Philipp ;
Bulla, Stefan ;
Baumann, Tobias ;
Siepe, Matthias ;
Winterer, Jan Thorsten ;
Euringer, Wulf ;
Schaefer, Arnd-Oliver ;
Kotter, Elmar ;
Langer, Mathias ;
Pache, Gregor .
RADIOLOGY, 2010, 255 (01) :207-217
[2]   Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality [J].
Flohr, Thomas G. ;
Leng, Shuai ;
Yu, Lifeng ;
Allmendinger, Thomas ;
Bruder, Herbert ;
Petersilka, Martin ;
Eusemann, Christian D. ;
Stierstorfer, Karl ;
Schmidt, Bernhard ;
McCollough, Cynthia H. .
MEDICAL PHYSICS, 2009, 36 (12) :5641-5653
[3]   High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates [J].
Goetti, Robert ;
Feuchtner, Gudrun ;
Stolzmann, Paul ;
Desbiolles, Lotus ;
Fischer, Michael Alexander ;
Karlo, Christoph ;
Baumueller, Stephan ;
Scheffel, Hans ;
Alkadhi, Hatem ;
Leschka, Sebastian .
EUROPEAN RADIOLOGY, 2010, 20 (11) :2565-2571
[4]   High-Pitch Dual-Source CT Angiography of the Thoracic and Abdominal Aorta: Is Simultaneous Coronary Artery Assessment Possible? [J].
Goetti, Robert ;
Baumueller, Stephan ;
Feuchtner, Gudrun ;
Stolzmann, Paul ;
Karlo, Christoph ;
Alkadhi, Hatem ;
Leschka, Sebastian .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) :938-944
[5]   High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG-synchronization [J].
Karlo, Christoph ;
Leschka, Sebastian ;
Goetti, Robert Paul ;
Feuchtner, Gudrun ;
Desbiolles, Lotus ;
Stolzmann, Paul ;
Plass, Andre ;
Falk, Volkmar ;
Marincek, Borut ;
Alkadhi, Hatem ;
Baumueller, Stephan .
EUROPEAN RADIOLOGY, 2011, 21 (01) :205-212
[6]   Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience [J].
Lell, Michael ;
Marwan, Mohamed ;
Schepis, Tiziano ;
Pflederer, Tobias ;
Anders, Katharina ;
Flohr, Thomas ;
Allmendinger, Thomas ;
Kalender, Willi ;
Ertel, Dirk ;
Thierfelder, Carsten ;
Kuettner, Axel ;
Ropers, Dieter ;
Daniel, Werner G. ;
Achenbach, Stephan .
EUROPEAN RADIOLOGY, 2009, 19 (11) :2576-2583
[7]   Transcatheter Aortic Valve Implantation Review of the Nature, Management, and Avoidance of Procedural Complications [J].
Masson, Jean-Bernard ;
Kovac, Jan ;
Schuler, Gerhard ;
Ye, Jian ;
Cheung, Anson ;
Kapadia, Samir ;
Tuzcu, Murat E. ;
Kodali, Susheel ;
Leon, Martin B. ;
Webb, John G. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (09) :811-820
[8]   Low-Kilovoltage, High-Tube-Current MDCT of Liver in Thin Adults: Pilot Study Evaluating Radiation Dose, Image Quality, and Display Settings [J].
Nakaura, Takeshi ;
Awai, Kazuo ;
Oda, Seitaro ;
Funama, Yoshinori ;
Harada, Kazunori ;
Uemura, Shouzaburou ;
Yamashita, Yasuyuki .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) :1332-1338
[9]   Motion artifacts of the aorta simulating aortic dissection on spiral CT [J].
Qanadli, SD ;
El Hajjam, M ;
Mesurolle, B ;
Lavisse, L ;
Jourdan, O ;
Randoux, B ;
Chagnon, S ;
Lacombe, P .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (01) :1-6
[10]   Thoracic aorta: Motion artifact reduction with retrospective and prospective electrocardiography-assisted multi-detector row CT [J].
Roos, JE ;
Willmann, JK ;
Weishaupt, D ;
Lachat, M ;
Marincek, B ;
Hilfiker, PR .
RADIOLOGY, 2002, 222 (01) :271-277