Generic Neutravidin Biosensor for Simultaneous Multiplex Detection of MicroRNAs via Electrochemically Encoded Responsive Nanolabels

被引:61
|
作者
Azzouzi, Sawsen [1 ,2 ,3 ]
Fredj, Zina [1 ,2 ,3 ]
Turner, Anthony P. F. [1 ,4 ]
Ben Ali, Mounir [2 ,3 ]
Mak, Wing Cheung [1 ]
机构
[1] Linkoping Univ, Biosensors & Bioelect Ctr, Dept Phys Chem & Biol IFM, S-58183 Linkoping, Sweden
[2] Univ Sousse, Higher Inst Appl Sci & Technol Sousse, GREENS ISSAT, Cite Ettafala, Ibn Khaldoun 4003, Sousse, Tunisia
[3] Ctr Res Microelect & Nanotechnol Sousse, NANOMISENE Lab, LR16CRMN01, Technopole Sousse BP 334, Sahloul 4034, Sousse, Tunisia
[4] Cranfield Univ, SATM, Cranfield MK43 0AL, Beds, England
基金
欧盟第七框架计划;
关键词
neutravidin biosensor; multiplex detection; microRNAs; molecular beacons; nanoparticle labels; LABEL-FREE; POSTTRANSCRIPTIONAL REGULATION; GOLD NANOPARTICLES; MOLECULAR BEACON; CANCER; PROBE; EXPRESSION; ASSAY;
D O I
10.1021/acssensors.8b00942
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Current electrochemical biosensors for multiple miRNAs require tedious immobilization of various nucleic acid probes. Here, we demonstrate an innovative approach using a generic neutravidin biosensor combined with electrochemically encoded responsive nanolabels for facile and simultaneous multiplexed detection of miRNA-21 and miRNA-141. The selectivity of the biosensor arises from the intrinsic properties of the electrochemically encoded responsive nanolabels, comprising biotinylated molecular beacons (biotin-MB) and metal nanoparticles (metal-NPs). The procedure is a simple one-pot assay, where the targeted miRNA causes the opening of biotin-MB followed by capturing of the biotin-MB-metal-NPs by the neutravidin biosensor and simultaneous detection of the captured metal-NPs by stripping square-wave voltammetry (SSWV). The multiplexed detection of miRNA-21 and miRNA-141 is achieved by differentiation of the electrochemical signature (i.e., the peak current) for the different metal-NP labels. The biosensor delivers simultaneous detection of miRNAs with a linear range of 0.5-1000 pM for miRNA-21 and a limit of detection of 0.3 pM (3 sigma/sensitivity, n = 3), and a range of 50-1000 pM for miRNA-141, with a limit of detection of 10 pM. Furthermore, we demonstrate multiplexed detection of miRNA-21 and miRNA-141 in a spiked serum sample.
引用
收藏
页码:326 / 334
页数:17
相关论文
共 42 条
  • [1] Multiplex microdisk biosensor based on simultaneous intensity and phase detection
    Blaesi, Johannes
    Gerken, Martina
    OPTICS EXPRESS, 2023, 31 (03) : 4319 - 4333
  • [2] Development of SPR biosensor for simultaneous detection of multiplex respiratory viruses
    Shi, Lei
    Sun, Qiuxiang
    He, Jian'an
    Xu, Hua
    Liu, Chunxiao
    Zhao, Chunzhong
    Xu, Yunqing
    Wu, Changlin
    Xiang, Junjian
    Gu, Dayong
    Long, Jun
    Lan, Hekui
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S2207 - S2216
  • [3] Ultrasimple size encoded microfluidic chip for rapid simultaneous multiplex detection of DNA sequences
    Tang, Man
    Zhu, Kuan-Jie
    Sun, Wei
    Yuan, Xinyue
    Wang, Zhipeng
    Zhang, Ruyi
    Ai, Zhao
    Liu, Kan
    BIOSENSORS & BIOELECTRONICS, 2024, 253
  • [4] Target-driven assembly of DNAzyme probes for simultaneous electrochemical detection of multiplex microRNAs
    Lin, Qitian
    Wu, Junye
    Jiang, Lili
    Kong, Dexian
    Xing, Chao
    Lu, Chunhua
    ANALYST, 2022, 147 (02) : 262 - 267
  • [5] Biosensor with electrochemically active nanocomposites for signal amplification and simultaneous detection of three ovarian cancer biomarkers
    Kovarova, Aneta
    Kastrati, Gylxhane
    Pekarkova, Jana
    Metelka, Radovan
    Drbohlavova, Jana
    Bilkova, Zuzana
    Selesovska, Renata
    Korecka, Lucie
    ELECTROCHIMICA ACTA, 2023, 469
  • [6] Biosensor with electrochemically active nanocomposites for signal amplification and simultaneous detection of three ovarian cancer biomarkers
    Kovarova, Aneta
    Kastrati, Gylxhane
    Pekarkova, Jana
    Metelka, Radovan
    Drbohlavova, Jana
    Bilkova, Zuzana
    Selesovska, Renata
    Korecka, Lucie
    ELECTROCHIMICA ACTA, 2023, 469
  • [7] A membrane biosensor based on colour differences encoded upconversion silica nanoparticles for multiplex nucleic acids detection
    Gu, Tongxu
    Zhong, Jiajun
    Wang, Zhe
    Bai, Pengli
    CHEMICAL ENGINEERING JOURNAL, 2023, 469
  • [8] Strand Displacement Amplification Reaction on Quantum Dot-Encoded Silica Bead for Visual Detection of Multiplex MicroRNAs
    Qu, Xiaojun
    Jin, Haojun
    Liu, Yuqian
    Sun, Qingjiang
    ANALYTICAL CHEMISTRY, 2018, 90 (05) : 3482 - 3489
  • [9] A colorimetric biosensor based on peroxidase-like activity of CuO nanoparticles for simultaneous detection of microRNAs
    Mahdie, Mohadese
    Rahaie, Mahdi
    Shateri, Fateme
    CHEMICAL PAPERS, 2022, 76 (12) : 7305 - 7312
  • [10] A colorimetric biosensor based on peroxidase-like activity of CuO nanoparticles for simultaneous detection of microRNAs
    Mohadese Mahdie
    Mahdi Rahaie
    Fateme Shateri
    Chemical Papers, 2022, 76 : 7305 - 7312