Relaxation-compensated fast multislice amide proton transfer (APT) imaging of acute ischemic stroke

被引:80
作者
Sun, Phillip Zhe [1 ]
Murata, Yoshihiro [2 ]
Lu, Jie [2 ,3 ]
Wang, Xiaoying [2 ]
Lo, Eng H. [2 ]
Sorensen, A. Gregory [1 ]
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Dept Radiol,Athinoula A Martinos Ctr Biomed Imagi, Charlestown, MA 02129 USA
[2] Massachusetts Gen Hosp, Dept Neurol, Charlestown, MA USA
[3] Capital Med Univ, Xuanwu Hosp, Dept Radiol, Beijing, Peoples R China
关键词
acute ischemia; amide proton transfer (APT); chemical exchange saturation transfer (CEST); pH; middle cerebral artery occlusion (MCAO); stroke; tissue acidosis;
D O I
10.1002/mrm.21591
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Amide proton transfer (APT) imaging is a variant form of chemical exchange saturation transfer (CEST) imaging that is based on the magnetization exchange between bulk water and labile endogenous amide protons. Given that chemical exchange is pH-dependent, APT imaging has been shown capable of imaging ischemic tissue acidosis, and as such, may serve as a surrogate metabolic imaging marker complementary to perfusion and diffusion MRI. In order for APT imaging to properly diagnose heterogeneous pathologies such as stroke and cancer, fast volumetric APT imaging has to be developed. In this study the evolution of CEST contrast after RF irradiation was solved showing that although the CEST steady state is reached by the apparent longitudinal relaxation rate, the decreases of CEST contrast after irradiation is governed by the intrinsic relaxation constant. A volumetric APT imaging sequence is proposed that acquires multislice images immediately after a single long continuous wave (CW) RF irradiation, wherein the relaxation-induced loss of CEST contrast is compensated for during postprocessing. The proposed technique was verified by numerical simulation, a tissue-like dual-pH phantom, and demonstrated on an embolic stroke animal model. In summary, our study has established a fast volumetric pH-weighted APT imaging technique, allowing further investigation to fully evaluate its diagnostic power.
引用
收藏
页码:1175 / 1182
页数:8
相关论文
共 31 条
[21]   Measurement of regional brain temperature using proton spectroscopic imaging: validation and application to acute ischemic stroke [J].
Marshall, Ian ;
Karaszewski, Bartosz ;
Wardlaw, Joanna M. ;
Cvoro, Vera ;
Wartolowska, Karolina ;
Armitage, Paul A. ;
Carpenter, Trevor ;
Bastin, Mark E. ;
Farrall, Andrew ;
Haga, Kristin .
MAGNETIC RESONANCE IMAGING, 2006, 24 (06) :699-706
[22]   Quantitative chemical exchange saturation transfer imaging of nuclear overhauser effects in acute ischemic stroke [J].
Msayib, Yunus ;
Harston, George W. J. ;
Ray, Kevin J. ;
Larkin, James R. ;
Sutherland, Brad A. ;
Sheerin, Fintan ;
Blockley, Nicholas P. ;
Okell, Thomas W. ;
Jezzard, Peter ;
Baldwin, Andrew ;
Sibson, Nicola R. ;
Kennedy, James ;
Chappell, Michael A. .
MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (01) :341-356
[23]   Fast diffusion kurtosis imaging in acute ischemic stroke shows mean kurtosis-diffusivity mismatch [J].
Hu, Ranliang ;
Kim, Hahnsung ;
Kim, Jinsuh ;
Allen, Jason W. ;
Sun, Phillip Zhe .
JOURNAL OF NEUROIMAGING, 2022, 32 (05) :941-946
[24]   Early identification of neonatal mild hypoxic-ischemic encephalopathy by amide proton transfer magnetic resonance imaging: A pilot study [J].
Chen, Sijin ;
Liu, Xilong ;
Mei, Yingjie ;
Li, Caixia ;
Ren, Daokun ;
Zhong, Mei ;
Xu, Yikai .
EUROPEAN JOURNAL OF RADIOLOGY, 2019, 119
[25]   Reliability of fast magnetic resonance imaging for acute ischemic stroke patients using a 1.5-T scanner [J].
Chung, Mi Sun ;
Lee, Ji Ye ;
Jung, Seung Chai ;
Baek, Seunghee ;
Shim, Woo Hyun ;
Park, Ji Eun ;
Kim, Ho Sung ;
Choi, Choong Gon ;
Kim, Sang Joon ;
Lee, Deok Hee ;
Jeon, Sang-Beom ;
Kang, Dong-Wha ;
Kwon, Sun U. ;
Kim, Jong S. .
EUROPEAN RADIOLOGY, 2019, 29 (05) :2641-2650
[26]   Reliability of fast magnetic resonance imaging for acute ischemic stroke patients using a 1.5-T scanner [J].
Mi Sun Chung ;
Ji Ye Lee ;
Seung Chai Jung ;
Seunghee Baek ;
Woo Hyun Shim ;
Ji Eun Park ;
Ho Sung Kim ;
Choong Gon Choi ;
Sang Joon Kim ;
Deok Hee Lee ;
Sang-Beom Jeon ;
Dong-Wha Kang ;
Sun U. Kwon ;
Jong S. Kim .
European Radiology, 2019, 29 :2641-2650
[27]   CT after interhospital transfer in acute ischemic stroke: Imaging findings and impact of prior intravenous contrast administration [J].
Mueller, Franziska ;
Fabritius, Matthias P. ;
Stueckelschweiger, Lena ;
Kiesl, Sophia ;
Moench, Sebastian ;
Tiedt, Steffen ;
Remi, Jan ;
Kellert, Lars ;
Herzberg, Moriz ;
Kuepper, Clemens ;
Dimitriadis, Konstantinos ;
Ricke, Jens ;
Puhr-Westerheide, Daniel ;
Liebig, Thomas ;
Kunz, Wolfgang G. ;
Reidler, Paul .
FRONTIERS IN NEUROLOGY, 2022, 13
[28]   Comparison of image sensitivity between conventional tensor-based and fast diffusion kurtosis imaging protocols in a rodent model of acute ischemic stroke [J].
Wu, Yin ;
Kim, Jinsuh ;
Chan, Suk-Tak ;
Zhou, Iris Yuwen ;
Guo, Yingkun ;
Igarashi, Takahiro ;
Zheng, Hairong ;
Guo, Gang ;
Sun, Phillip Zhe .
NMR IN BIOMEDICINE, 2016, 29 (05) :625-630
[29]   Predicting a Favorable (mRS 0-2) or Unfavorable (mRS 3-6) Stroke Outcome by Arterial Spin Labeling and Amide Proton Transfer Imaging in Post-Thrombolysis Stroke Patients [J].
He, Qinmeng ;
Li, Guomin ;
Jiang, Meien ;
Zhou, Qianling ;
Gao, Yunyu ;
Yan, Jianhao .
JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (02)
[30]   Investigating the origin of pH-sensitive magnetization transfer ratio asymmetry MRI contrast during the acute stroke: Correction of T1 change reveals the dominant amide proton transfer MRI signal [J].
Wu, Limin ;
Jiang, Liang ;
Sun, Phillip Zhe .
MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) :2702-2712