Efficacy, safety, and feasibility of volumetric modulated arc therapy for synchronous bilateral breast cancer management

被引:3
|
作者
Quesada, Stanislas [1 ,2 ]
Fenoglietto, Pascal [2 ]
Gourgou, Sophie [3 ]
Lemanski, Claire [2 ]
Draghici, Roxana [2 ]
Ailleres, Norbert [2 ]
Prunaretty, Jessica [2 ]
Azria, David [1 ,2 ,3 ]
Bourgier, Celine [1 ,2 ,3 ]
机构
[1] Univ Montpellier, Fac Med, Montpellier, France
[2] Montpellier Canc Inst ICM, Dept Radiat Oncol, Montpellier, France
[3] Inst Canc Res Montpellier IRCM, Montpellier, France
来源
FRONTIERS IN ONCOLOGY | 2022年 / 12卷
关键词
bilateral breast cancer; radiotherapy; VMAT; treatment planning; cancer care; dosimetric analysis; treatment outcome; HELICAL TOMOTHERAPY; RADIATION-THERAPY; RADIOTHERAPY; IRRADIATION; SURVIVAL;
D O I
10.3389/fonc.2022.967479
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PurposeVolumetric Modulated Arc Therapy (VMAT) exhibits potent advantages regarding target volume coverage and protection of organs at risk, notably in the context of anatomical constraints. Nevertheless, reports concerning VMAT for the treatment of synchronous bilateral breast cancers (SBBC) have been scarce to date. As such, we conducted this observational study to assess efficacy, safety and feasibility of VMAT in SBBC. Materials and MethodsFrom August 2011 to December 2017, 54 consecutive patients with SBBC with or without axillary nodes involvement underwent a treatment protocol containing radiotherapy using VMAT. A total dose (TD) of 52.2Gy in 29 fractions was delivered to breast and internal mammary chain (IMC) nodes Planning Target Volume (PTV) plus, if applicable, a TD of 49.3Gy in 29 fractions to the supra- and infra-clavicular nodes PTV and a TD of 63.22Gy in 29 fractions to tumor boost PTV. Lungs, heart, esophagus, trachea, liver, thyroid and spinal cord were considered as organs at risk. VMAT feasibility and organ at risk sparing were evaluated by treatments planning of the 20 first enrolled patients. Tolerance and patients' outcome were prospectively monitored by acute/late toxicities records and by the analysis of overall survival (OS), locoregional recurrence-free survival (LRFS) and recurrence-free survival (RFS). ResultsBreast, supraclavicular nodes and boost PTV coverage was adequate with at least 98% of PTV encompassed by more than 95% of the prescribed dose. Less than 90% of IMC PTV was encompassed by 95% of the prescribed dose. Mean lung dose was 12.3Gy (range: 7.7 - 18.7); mean heart dose was 10.7Gy (range: 6.2 - 22.3). Concerning acute toxicities, only 2 patients experienced grade 3 skin toxicity (3.7%) and only 1 patient developed grade 1 pneumonitis. After a median follow-up of 5.3 years, grade 2 fibrosis and/or shrinking was observed in 5 patients (10%), and grade 3 fibrosis in 1 patients (2%). The 5-year LRFS-rate, RFS-rate and OS were 98% [95% CI= 86.12-99.70%], 96% [95% CI= 84.63-98.96%] and 100%, respectively.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Synchronous bilateral breast cancer irradiation: clinical and dosimetrical issues using volumetric modulated arc therapy and simultaneous integrated boost
    Fiorentino, Alba
    Mazzola, Rosario
    Naccarato, Stefania
    Giaj-Levra, Niccolo
    Fersino, Sergio
    Sicignano, Gianluisa
    Tebano, Umberto
    Ricchetti, Francesco
    Ruggieri, Ruggero
    Alongi, Filippo
    RADIOLOGIA MEDICA, 2017, 122 (06): : 464 - 471
  • [2] Volumetric modulated arc therapy for synchronous bilateral whole breast irradiation - A case study
    Seppala, Jan
    Heikkila, Janne
    Myllyoja, Kimmo
    Koskela, Kristiina
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2015, 20 (05) : 398 - 402
  • [3] Treatment planning evaluation for bilateral breast cancer using volumetric modulated arc therapy (VMAT)
    Abdullah, Siham Sabah
    Alabedi, Haydar H.
    Taha, Jenan Hussein
    Abdullah, Khalid
    REVISTA DE SENOLOGIA Y PATOLOGIA MAMARIA, 2023, 36 (01):
  • [4] Dosimetric comparison of volumetric-modulated arc therapy and helical tomotherapy for adjuvant treatment of bilateral breast cancer
    Phurailatpam, Reena
    Wadasadawala, Tabassum
    Chauhan, Kamalnayan
    Panda, Subhajit
    Sarin, Rajiv
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 36 - 44
  • [5] Patient specific quality assurance of volumetric modulated arc therapy of synchronous bilateral breast cancer
    Zamo, Francis C. Djoumessi
    Njeh, Christopher F.
    Colliaux, Anthony
    Blot-Lafond, Valerie
    Moyo, M. Ndontchueng
    MEDICAL DOSIMETRY, 2024, 49 (03) : 177 - 184
  • [6] Dosimetric Comparision of Coplanar versus Noncoplanar Volumetric Modulated Arc Therapy for Treatment of Bilateral Breast Cancers
    Bharati, Avinav
    Rath, Satyajeet
    Khurana, Rohini
    Rastogi, Madhup
    Mandal, Susama R.
    Gandhi, Ajeet Kumar
    Hadi, Rahat
    Srivastava, Anoop K.
    Mishra, Surendra Prasad
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (03) : 252 - 258
  • [7] An efficient treatment planning approach to reduce the critical organ dose in volumetric modulated arc therapy for synchronous bilateral breast cancer patients
    Lin, Y. F.
    Shueng, P. W.
    Lin, H. H.
    Tien, H. J.
    Lai, L. H.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 174
  • [8] Critical appraisal of the role of volumetric modulated arc therapy in the radiation therapy management of breast cancer
    Cozzi, Luca
    Lohr, Frank
    Fogliata, Antonella
    Franceschini, Davide
    De Rose, Fiorenza
    Filippi, A. R.
    Guidi, Gabriele
    Vanoni, Valentina
    Scorsetti, Marta
    RADIATION ONCOLOGY, 2017, 12
  • [9] Intensity Modulated Radiotherapy and Volumetric Modulated Arc Therapy in the Treatment of Breast Cancer: An Updated Review
    Chang, Jee Suk
    Chang, Ji Hyun
    Kim, Nalee
    Kim, Yong Bae
    Shin, Kyung Hwan
    Kim, Kyubo
    JOURNAL OF BREAST CANCER, 2022, 25 (05) : 349 - 365
  • [10] Synchronous bilateral breast cancer irradiation: clinical and dosimetrical issues using volumetric modulated arc therapy and simultaneous integrated boost
    Alba Fiorentino
    Rosario Mazzola
    Stefania Naccarato
    Niccolò Giaj-Levra
    Sergio Fersino
    Gianluisa Sicignano
    Umberto Tebano
    Francesco Ricchetti
    Ruggero Ruggieri
    Filippo Alongi
    La radiologia medica, 2017, 122 : 464 - 471