Mechanical model for unbonded seven-wire tendon with symmetric wire breaks

被引:17
|
作者
MacDougall, C [1 ]
Bartlett, FM
机构
[1] Queens Univ, Dept Civil Engn, Kingston, ON K7L 3N6, Canada
[2] Univ Western Ontario, Dept Civil & Environm Engn, London, ON N6A 5B9, Canada
来源
JOURNAL OF ENGINEERING MECHANICS-ASCE | 2005年 / 131卷 / 12期
关键词
concrete; post tensioning; corrosion; laboratory tests; mathematical models; tendons; friction;
D O I
10.1061/(ASCE)0733-9399(2005)131:12(1239)
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A mechanical model for unbonded seven-wire tendons with broken wires that accounts for the effects of interwire friction and contact forces between the tendon and surrounding concrete is derived. The model is an essential tool for predicting the response, and reliability, of unbonded posttensioned concrete structures containing corroded tendons with broken wires. For the case where the broken wires are symmetrically arranged around the tendon cross section, the model predicts: (1) the strain variation with distance from the break in the broken and unbroken wires; (2) the affected length, where strains in the broken wires are less than those in the unbroken wires; and (3) the prestress force remaining after wire breaks occur. The affected length has practical significance because techniques used in practice to detect wire breaks will fail if performed outside the affected length. Experimental data obtained using a novel strongback beam confirm the response predicted by the model and indicate the coefficient of interwire friction is 0.164 for uncorroded tendons.
引用
收藏
页码:1239 / 1247
页数:9
相关论文
共 50 条
  • [1] Mechanical model for unbonded seven-wire tendon with single broken wire
    MacDougall, Colin
    Bartlett, F. Michael
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 2006, 132 (12): : 1345 - 1353
  • [2] Tests of unbonded seven-wire tendon with broken outer wires
    MacDougall, C
    Bartlett, FM
    ACI STRUCTURAL JOURNAL, 2003, 100 (05) : 581 - 588
  • [3] Tests of corroded unbonded seven-wire tendons with broken wires
    MacDougall, C
    Bartlett, FM
    ACI STRUCTURAL JOURNAL, 2002, 99 (06) : 803 - 810
  • [4] Determining broken wires in unbonded seven-wire strands using penetration tests
    MacDougall, Colin
    Li, Shulian
    PCI JOURNAL, 2007, 52 (05): : 96 - 104
  • [5] Effect of temperature on the mechanical properties of low relaxation seven-wire prestressing strand
    Shakya, A. M.
    Kodur, V. K. R.
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 124 : 74 - 84
  • [6] Numerical Simulation of Crack Propagation in Seven-Wire Strand
    Kastratovic, Gordana
    Vidanovic, Nenad
    Grbovic, Aleksandar
    Mirkov, Nikola
    Rasuo, Bosko
    COMPUTATIONAL AND EXPERIMENTAL APPROACHES IN MATERIALS SCIENCE AND ENGINEERING, CNNTECH 2019, 2020, 90 : 76 - 91
  • [7] Effects of enhanced confinement on cyclic behavior of concrete bridge columns with partially unbonded seven-wire steel strands
    Ou, Yu -Chen
    Wu, Jhen-Wei
    ENGINEERING STRUCTURES, 2024, 314
  • [8] Strength reduction curves for corroded seven-wire strands
    Marra, Matteo
    Palermo, Michele
    Trombetti, Tomaso
    Silvestri, Stefano
    EUROPEAN ASSOCIATION ON QUALITY CONTROL OF BRIDGES AND STRUCTURES, EUROSTRUCT 2023, VOL 6, ISS 5, 2023, : 1 - 8
  • [9] Cyclic behavior of bridge columns with partially unbonded seven-wire steel strands to increase post-yield stiffness
    Ou, Yu-Chen
    Wu, Jhen-Wei
    Yuniati Pratiwi, Ade
    Engineering Structures, 2022, 258
  • [10] Determining bond strength of seven-wire strands in prestressed concrete
    Mohandoss, Prabha
    Pillai, Radhakrishna G.
    Gettu, Ravindra
    STRUCTURES, 2021, 33 : 2413 - 2423