Optimizing the performance of organics and nutrient removal in constructed wetland-microbial fuel cell systems

被引:70
作者
Wang, Xiaoou [1 ]
Tian, Yimei [1 ]
Liu, Hong [2 ]
Zhao, Xinhua [1 ]
Peng, Sen [1 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300350, Peoples R China
[2] Oregon State Univ, Dept Biol & Ecol Engn, 116 Gilmore Hall, Corvallis, OR 97331 USA
关键词
Constructed wetland; Microbial fuel cell; Orthogonal experiment; Organics; Nitrogen; Phosphorus; WASTE-WATER TREATMENT; ELECTRICITY PRODUCTION; IONIC-STRENGTH; DENITRIFICATION; OPERATION; BATCH;
D O I
10.1016/j.scitotenv.2018.11.005
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
No studies have reported the operation optimization of constructed wetland-microbial fuel cell (CW-MFC) systems in terms of pollutant removal under the influence of multiple factors. Multifactor orthogonal experiment (L25(55)) was designed in this study to investigate the influence ofmultiple factors on the CW-MFC performance and determine the optimal operating conditions for the organics and nutrient removal. The tested factors include volume ratio of granular graphite in the substrates (A), dissolved oxygen (DO) concentration in the cathode zone (B), hydraulic retention time (HRT) (C), effluent reflux ratio (D), and external resistance (E). The results showed that the sequence and degree of the influence of the tested factors were C** > B** > E** > D* > A for chemical oxygen demand (CODCr) removal, C** > B** > D* > E > A for ammonia nitrogen (NH3-N) removal, C** > D** > B** > E* > A* for total nitrogen (TN) removal, and C** > D* > B > A > E for total phosphorus (TP) removal (* denotes significant influence (0.01 < p < 0.05) and ** denotes extremely significant influence (p = 0.01)). HRT was found to be the most influential factor for pollutant removal in CW-MFCs with a contribution of over 50% for CODCr, NH3-N and TP removal, and over 45% for TN removal. The optimal operating conditions for CODCr, NH3-N, TN and TP removal in CW-MFCs were quite different from each other. Comprehensively considering the treatment efficiency of pollutant, treatment capacity ofwastewater, and energy consumption fromartificial aeration, the selected comprehensive optimal operating conditions for CW-MFCs were A=20%, B=1.5 mg/L, C=1.5 days, D <= 50%, and E =250 Omega. Moreover, incorporating the MFC significantly enhanced the organics and nitrogen removal in CWs by 8.72-11.04% CODCr and 9.78-12.04% TN. (c) 2018 Elsevier B. V. All rights reserved.
引用
收藏
页码:860 / 871
页数:12
相关论文
共 25 条
[1]   A review of a recently emerged technology: Constructed wetland - Microbial fuel cells [J].
Doherty, Liam ;
Zhao, Yaqian ;
Zhao, Xiaohong ;
Hu, Yuansheng ;
Hao, Xiaodi ;
Xu, Lei ;
Liu, Ranbin .
WATER RESEARCH, 2015, 85 :38-45
[2]   The effects of electrode spacing and flow direction on the performance of microbial fuel cell-constructed wetland [J].
Doherty, Liam ;
Zhao, Xiaohong ;
Zhao, Yaqian ;
Wang, Wenke .
ECOLOGICAL ENGINEERING, 2015, 79 :8-14
[3]   Electricity production from Azo dye wastewater using a microbial fuel cell coupled constructed wetland operating under different operating conditions [J].
Fang, Zhou ;
Song, Hai-liang ;
Cang, Ning ;
Li, Xian-ning .
BIOSENSORS & BIOELECTRONICS, 2015, 68 :135-141
[4]  
Hu C. R., 2008, EXPT DESIGN DATA PRO
[5]   Phosphorus removal enhancement of magnesium modified constructed wetland microcosm and its mechanism study [J].
Lan, Wei ;
Zhang, Jian ;
Hu, Zhen ;
Ji, Mingde ;
Zhang, Xinwen ;
Zhang, Jianda ;
Li, Fazhan ;
Yao, Guoqing .
CHEMICAL ENGINEERING JOURNAL, 2018, 335 :209-214
[6]   Production of electricity from acetate or butyrate using a single-chamber microbial fuel cell [J].
Liu, H ;
Cheng, SA ;
Logan, BE .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (02) :658-662
[7]   Power generation in fed-batch microbial fuel cells as a function of ionic strength, temperature, and reactor configuration [J].
Liu, H ;
Cheng, SA ;
Logan, BE .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (14) :5488-5493
[8]   A review of incorporation of constructed wetland with other treatment processes [J].
Liu, Ranbin ;
Zhao, Yaqian ;
Doherty, Liam ;
Hu, Yuansheng ;
Hao, Xiaodi .
CHEMICAL ENGINEERING JOURNAL, 2015, 279 :220-230
[9]   Bio-cathode materials evaluation and configuration optimization for power output of vertical subsurface flow constructed wetland - Microbial fuel cell systems [J].
Liu, Shentan ;
Song, Hailiang ;
Wei, Size ;
Yang, Fei ;
Li, Xianning .
BIORESOURCE TECHNOLOGY, 2014, 166 :575-583
[10]  
Luca G.A.D, 2017, ECOL ENG, V108, P227, DOI DOI 10.1016/j.ecoleng.2017.08.038