A Testicular Tubule Evaluation Method by Ultrasonic Array Probe

被引:0
|
作者
Takashima, Yuya [1 ]
Kuramoto, Kei [1 ,2 ]
Kobashi, Syoji [1 ,2 ]
Hata, Yutaka [1 ,2 ]
Ishikawa, Tomomoto [3 ]
机构
[1] Univ Hyogo, Grad Sch Engn, Kobe, Hyogo 6500044, Japan
[2] Osaka Univ, WPI, Immunol Frontie Res Ctr, Suita, Osaka 565, Japan
[3] Ishikawa Hosp, Hyogo, Japan
关键词
medical system; ultrasonic; cumulative relative frequency; azoospermia; testicular tubule;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper describes a testicular tubules evaluation using 1.0MHz ultrasonic array probe. In this system, we evaluate a diameter of testicular tubules. We employ an ultrasonic array probe with the center frequency of 1.0MHz. We employ evaluation index that cumulative relative frequency of amplitude values. In the experiment, we employ 24 nylon lines as the testicular tubules. Amplitude of large nylon line echo is larger than that of small nylon echo. For the evaluation, we calculate cumulative relative frequency amplitude of acquisition data. Fuzzy if-then rules are made by the cumulative relative frequency of large and small lines. We evaluate a rate of large lines among all lines by using the fuzzy MIN-MAX center-of-gravity method. In this experiment, the proposed method successfully evaluated the rate of the large lines. We changed the rate of large lines in 24 nylon lines, and tested our method 20 times for each rate. We evaluated the rate with 5.77 % in mean absolute error.
引用
收藏
页码:1013 / 1016
页数:4
相关论文
共 50 条
  • [11] Rapid ultrasonic array assessment framework method for evaluating ultrasonic array transducer performance
    Sun, Xiaoyu
    Croxford, Anthony J.
    Drinkwater, Bruce W.
    APPLIED ACOUSTICS, 2021, 182
  • [12] Analysis Method on Effect of Inactive Elements in a Phased Array Ultrasonic Probe Using Full Matrix Capture
    Lee, Tae-Hun
    Kwak, Dong-Ryul
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2019, 39 (04) : 217 - 224
  • [13] Experimental validation of a phased array probe model in ultrasonic inspection
    Lei, Xiangyu
    Wirdelius, Hakan
    Rosell, Anders
    ULTRASONICS, 2020, 108 (108)
  • [14] Trans-skull Imaging System by Ultrasonic Array Probe
    Hiramatsu, Genta
    Ikeda, Yuichiro
    Kobashi, Syoji
    Hata, Yutaka
    Imawaki, Seturo
    Kitamura, Yuri
    Yanagida, Toshio
    2009 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS (SMC 2009), VOLS 1-9, 2009, : 1096 - +
  • [15] Cross-coupling properties of ultrasonic phased array probe
    Adachi, H
    Funakubo, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2000, 39 (10): : 6077 - 6083
  • [16] QUANTITATIVE EVALUATION OF DIAGNOSTIC ULTRASONIC PROBE RESPONSE
    ERICKSON, JJ
    BRILL, AB
    PHYSICS IN MEDICINE AND BIOLOGY, 1971, 16 (01): : 170 - &
  • [17] A quantitative evaluation method for acoustic performances of partial discharge's ultrasonic array sensors
    Xie, Q., 1600, Chinese Society for Electrical Engineering (34):
  • [18] Study on Total Focusing Method Imaging of Irregular Surface Specimen Using Flexible Phased Array Ultrasonic Probe
    Lee, Tae-Hun
    Kwak, Dong-Ryul
    Kim, Wang-Bae
    Lee, Seung-Pyo
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2020, 40 (05) : 353 - 360
  • [19] Method of Processing of Ultrasonic Signal of Phased Array
    Asochakov, A. S.
    Shulgina, Y. V.
    Soldatov, A. I.
    Shulgin, E. M.
    Ogorodnikov, D. N.
    2015 INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING, AUTOMATION AND CONTROL SYSTEMS (MEACS), 2015,
  • [20] Phased array ultrasonic probe simulation and designing for railway axle inspection
    Peng Chaoyong
    Gao Xiaorong
    Peng Jianping
    Wu Dongdong
    Yang Yang
    PROCEEDINGS OF 2016 IEEE FAR EAST FORUM ON NONDESTRUCTIVE EVALUATION/TESTING: NEW TECHNOLOGY & APPLICATION (IEEE FENDT 2016), 2016, : 232 - 234