Robust Motion Control Architecture for an Upper-Limb Rehabilitation Exosuit

被引:5
作者
Pont-Esteban, David [1 ]
Sanchez-Uran, Miguel Angel [1 ]
Ferre, Manuel [1 ]
机构
[1] Univ Politecn Madrid, Ctr Automat & Robot UPM CSIC, Madrid 28006, Spain
关键词
Elbow; Exoskeletons; Uncertainty; Robustness; Shoulder; Systems architecture; Microcontrollers; Motion control; Sliding mode control; Patient rehabilitation; Medical treatment; exoskeletons; control architectures; rehabilitation robotics; sliding-mode control; SLIDING MODE CONTROL; NONLINEAR DISTURBANCE OBSERVER; TRACKING CONTROL; EXOSKELETON; SYSTEM; JOINT;
D O I
10.1109/ACCESS.2022.3217528
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Upper-limb exosuits are light wearable devices suitable for applications such as rehabilitation or assistance in industrial environments. One of the main drawbacks of these systems is the amount of uncertainties intrinsic to the nature of the device. Moreover, the direct interaction between the exosuit and its user adds disturbances to the system. Therefore, a robust control architecture to these phenomena is required for its appropriate control. In this article, a robust motion (position and speed) control architecture based on a cascade proportional-integral (PI) and a sliding mode controller (SMC), and a nonlinear disturbance observer (NDO) for the upper-limb cable-driven rehabilitation exosuit LUXBIT is designed. We call the proposed controller by the acronym CPISDO. The SMC nature allows to compensate the matched disturbances and uncertainties, while the NDO counteracts the unmatched ones. The PI component helps in reducing tracking error. Dynamic modelling, system architecture and control design are addressed. The CPISDO controller has been implemented over the exosuit and several experiments have been performed over 10 healthy subjects to evaluate the controller's tracking performance as well as the disturbance rejection. Supertwisting (a state-of-the-art SMC) and PI controllers have been implemented for CPISDO validation. Results are compared with other state-of-the-art solutions.
引用
收藏
页码:113631 / 113648
页数:18
相关论文
共 44 条
[1]   Design, control, and testing of a thumb exoskeleton with series elastic actuation [J].
Agarwal, Priyanshu ;
Yun, Youngmok ;
Fox, Jonas ;
Madden, Kaci ;
Deshpande, Ashish D. .
INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2017, 36 (03) :355-375
[2]   Review of Control Methods for Upper Limb Telerehabilitation With Robotic Exoskeletons [J].
Bauer, Georgeta ;
Pan, Ya-Jun .
IEEE ACCESS, 2020, 8 :203382-203397
[3]  
Berge G., 2002, 1 U BERG DEP MATH, P41
[4]  
Dinh BK, 2016, 2016 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2016), P5670, DOI 10.1109/IROS.2016.7759834
[5]   A hip-knee-ankle exoskeleton emulator for studying gait assistance [J].
Bryan, Gwendolyn M. ;
Franks, Patrick W. ;
Klein, Stefan C. ;
Peuchen, Robert J. ;
Collins, Steven H. .
INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2021, 40 (4-5) :722-746
[6]  
Chen SY, 2017, 2017 32ND YOUTH ACADEMIC ANNUAL CONFERENCE OF CHINESE ASSOCIATION OF AUTOMATION (YAC), P559, DOI 10.1109/YAC.2017.7967473
[7]   A nonlinear disturbance observer for robotic manipulators [J].
Chen, WH ;
Ballance, DJ ;
Gawthrop, PJ ;
O'Reilly, J .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (04) :932-938
[8]  
Chiaradia D, 2018, 2018 IEEE INTERNATIONAL CONFERENCE ON SOFT ROBOTICS (ROBOSOFT), P565, DOI 10.1109/ROBOSOFT.2018.8405386
[9]   Hierarchical Cascade Controller for Assistance Modulation in a Soft Wearable Arm Exoskeleton [J].
Dinh, Binh Khanh ;
Xiloyannis, Michele ;
Antuvan, Chris Wilson ;
Cappello, Leonardo ;
Masia, Lorenzo .
IEEE ROBOTICS AND AUTOMATION LETTERS, 2017, 2 (03) :1786-1793
[10]  
Edwards C., 2014, IEEE 13 INT WORKSH V, V47, P1