An in situ applicable colorimetric Cu2+ sensor using quantum dot quenching

被引:14
作者
Chen, Qingai [2 ]
Zhou, Tingyao [1 ]
He, Chunyan [3 ]
Jiang, Yaqi [1 ]
Chen, Xi [1 ]
机构
[1] Xiamen Univ, State Key Lab Marine Environm Sci, Xiamen 361005, Peoples R China
[2] Fujian Agr & Forestry Univ, Coll Food Sci, Fuzhou 350002, Peoples R China
[3] Fuzhou Univ, Dept Chem, Minist Educ, Key Lab Anal & Detect Technol Food Safety, Fuzhou 350002, Peoples R China
关键词
SOLID-PHASE EXTRACTION; COPPER; SPECTROMETRY; SAMPLES; OXYGEN;
D O I
10.1039/c1ay05023k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a rapid, convenient and in situ applicable Cu2+ sensor was constructed based on a luminescent layer immobilizing Ru (bpy)(3)Cl-2 with a maximum wavelength of 600 nm, which was taken as the reference background light. The luminescence intensity of the layer was kept constant and isolated from the oxygen change in the solution due to the hybrid polyacrylonitrile-dimethylsulfoxide used in the immobilization of the Ru(bpy)(3)Cl-2. The CdTe quantum dot (QD) luminescence, with a maximum wavelength of 520 nm, was quenched to different degrees depending on the Cu2+ concentration in the solution. Using a commercial camera, different colors could be captured in different Cu2+ concentrations. This color change was caused by the composite light with stable luminescence from the Ru (bpy)(3)Cl-2 layer and the changeable fluorescence of the CdTe QDs. Sensor characteristics, including the co-existing ions, oxygen content, temperature effect, and sensor stability, were investigated.
引用
收藏
页码:1471 / 1474
页数:4
相关论文
共 15 条
[1]   A rapid and selective carbon composite platinum coated electrode for determination of copper ion in real samples [J].
Abbaspour, Abdolkarim ;
Norouz-Sarvestani, Fatemeh ;
Sharghi, Hashem ;
Moeini, Fatemeh .
ANALYTICAL METHODS, 2010, 2 (10) :1522-1527
[2]  
Biju V, 2005, J PHYS CHEM B, V109, P13899, DOI 10.1021/jp0504241
[3]   Colorimetric optical pH sensor production using a dual-color system [J].
Chen, Hai-xu ;
Wang, Xu-dong ;
Song, Xin-hong ;
Zhou, Ting-yao ;
Jiang, Ya-qi ;
Chen, Xi .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 146 (01) :278-282
[4]   Fluorescent gold nanoparticles-based fluorescence sensor for Cu2+ ions [J].
Chen, Wenbin ;
Tu, Xijuan ;
Guo, Xiangqun .
CHEMICAL COMMUNICATIONS, 2009, (13) :1736-1738
[5]   Characterization of ormosil film for dissolved oxygen-sensing [J].
Chen, X ;
Zhong, ZM ;
Li, Z ;
Jiang, YQ ;
Wang, XR ;
Wong, KY .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 87 (02) :233-238
[6]   Application of cotton as a solid phase extraction sorbent for on-line preconcentration of copper in water samples prior to inductively coupled plasma optical emission spectrometry determination [J].
Faraji, Mohammad ;
Yamini, Yadollah ;
Shariati, Shahab .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 166 (2-3) :1383-1388
[7]   Fabrication of a Colorimetric Electrochemiluminescence Sensor [J].
Lin, Zhi-jie ;
Chen, Xiao-mei ;
Jia, Tian-tian ;
Wang, Xu-dong ;
Xie, Zhao-xiong ;
Oyama, Munetaka ;
Chen, Xi .
ANALYTICAL CHEMISTRY, 2009, 81 (02) :830-833
[8]   Application of glow discharge mass spectrometry to multielement ultra-trace determination in ultrahigh-purity copper and iron: a calibration approach achieving quantification and traceability [J].
Matschat, Ralf ;
Hinrichs, Joachim ;
Kipphardt, Heinrich .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (01) :125-141
[9]   URINARY COPPER LOSSES IN INFANTS RECEIVING FREE AMINO-ACID SOLUTIONS [J].
TYRALA, EE ;
BRODSKY, NL ;
AUERBACH, VH .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1982, 35 (03) :542-545
[10]   Reversible optical sensor strip for oxygen [J].
Wang, Xu-dong ;
Chen, Xi ;
Xie, Zhao-xiong ;
Wang, Xiao-ru .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2008, 47 (39) :7450-7453