Natural ventilation efficiency in a bedroom with a central-pivoting window

被引:16
作者
Chou, Po-Cheng [1 ]
Chiang, Che-Ming [2 ]
Li, Yen-Yi [1 ]
Lee, Chia-Yen [3 ]
Chang, Kuei-Feng [4 ]
机构
[1] Shu Te Univ, Dept Interior Design, Kaohsiung, Kaohsiung, Taiwan
[2] Natl Cheng Kung Univ, Dept Architecture, Tainan 70101, Taiwan
[3] Da Yeh Univ, Dept Mech & Automat Engn, Changhua, Taiwan
[4] Natl Pingtung Inst Commerce, Dept Real Estate Management, Pingtung, Taiwan
关键词
air change rate (ACH); air exchange rate (AEE); carbon dioxide; center-pivoting window; computational fluid dynamics (CFD); natural ventilation; ventilation efficiency;
D O I
10.1177/1420326X08089621
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study analyzes the ventilation efficiency of a bedroom with a wall-mounted center-pivoting window. Numerical simulations and experiments were performed to investigate the airflow and the pollutant distribution in the bedroom. The air exchange rate and the carbon dioxide concentration profiles were investigated for various window opening angles and inlet wind velocities. The computational fluid dynamics analysis and experimental results presented provide a comprehensive understanding of the typical natural ventilation characteristics of a wall-mounted center-pivoting window in a bedroom of a typical home in Taiwan.
引用
收藏
页码:164 / 172
页数:9
相关论文
共 33 条
[1]   Design analysis of single-sided natural ventilation [J].
Allocca, C ;
Chen, QY ;
Glicksman, LR .
ENERGY AND BUILDINGS, 2003, 35 (08) :785-795
[2]  
[Anonymous], 1980, SERIES COMPUTATIONAL, DOI [DOI 10.1201/9781482234213, 10.1201/9781482234213]
[3]   Buoyancy-driven displacement natural ventilation in a single-zone building with three-level openings [J].
Chen, ZD ;
Li, YG .
BUILDING AND ENVIRONMENT, 2002, 37 (03) :295-303
[4]   Modelling and monitoring natural ventilation for conventional kitchens in Taiwan with transoms replaced with porous screens [J].
Chiang, CM ;
Chang, KF ;
Lee, CY ;
Chou, PC .
INDOOR AND BUILT ENVIRONMENT, 2006, 15 (02) :173-178
[5]  
CHOU PC, 1998, 1 C ARCH DES TECHN P, V1, P178
[6]   Influence of ventilation routes on indoor pollutant elimination in a working environment [J].
Chou, Po-Cheng ;
Chiang, Che-Ming ;
Lee, Chia-Yen ;
Ho, Ming-Chin .
INDOOR AND BUILT ENVIRONMENT, 2006, 15 (05) :473-481
[7]   Effect of ventilation pattern on room air and contaminant distribution [J].
Chung, KC ;
Hsu, SP .
BUILDING AND ENVIRONMENT, 2001, 36 (09) :989-998
[8]  
*CIBSE APPL MAN, 1997, NAT VENT NOND BUILD, V10, P97
[9]   Simulation of wind-driven ventilative cooling systems for an apartment building in Beijing and Shanghai [J].
da Graça, GC ;
Chen, Q ;
Glicksman, LR ;
Norford, LK .
ENERGY AND BUILDINGS, 2002, 34 (01) :1-11
[10]   Natural ventilation performance of a double-skin facade with a solar chimney [J].
Ding, WT ;
Hasemi, YJ ;
Yamada, T .
ENERGY AND BUILDINGS, 2005, 37 (04) :411-418