Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns-cast-free vs 3D printed cast-based

被引:9
作者
Graf, Tobias [1 ]
Gueth, Jan-Frederik [1 ]
Diegritz, Christian [2 ]
Liebermann, Anja [3 ]
Schweiger, Josef [3 ]
Schubert, Oliver [3 ]
机构
[1] Goethe Univ Frankfurt, Ctr Dent & Oral Med, Dept Prosthodont, Frankfurt, Germany
[2] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Conservat Dent & Periodont, Munich, Germany
[3] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Prosthet Dent, Munich, Germany
关键词
CAD-CAM; Cast-free; Digital workflow; Single implant crown; 3D printing; Time-efficiency; POSITION STABILITY; DIGITAL WORKFLOW; IMPRESSIONS; ACCURACY; TIME; ABUTMENT; SYSTEMS;
D O I
10.4047/jap.2021.13.6.351
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. The aim of this study was to evaluate the efficiency of occlusal and interproximal adjustments of single implant crowns (SIC), comparing a digital cast-free approach (CF) and a protocol using 3D printed casts (PC). MATERIALS AND METHODS. A titanium implant was inserted at position of lower right first molar in a typodont. The implant position was scanned using an intraoral scanner and SICs were fabricated accordingly. Ten crowns (CF; n = 10) were subject to a digital cast-free workflow without any labside occlusal and interproximal modifications. Ten other identical crowns (PC) were adjusted to 3D printed casts before delivery. All crowns were then adapted to the testing model, simulating chair-side adjustments during clinical placement. Adjustment time, quantity of adjustments, and contact relationship were assessed. Data were analyzed using SPSS software (P < .05). RESULTS. Median and interquartile range (IQR) of clinical adjustment time was 02:44 (IQR 00:45) minutes in group CF and 01:46 (IQR 00:21) minutes in group PC. Laboratory and clinical adjustment time in group PC was 04:25 (IQR 00:59) minutes in total. Mean and standard deviation (+/- SD) of root mean squared error (RMSE) of quantity of clinical adjustments was 45 +/- 7 mu m in group CF and 34 +/- 6 mu m in group PC. RMSE of total adjustments was 61 +/- 11 mu m in group PC. Quality of occlusal contacts was better in group CF. CONCLUSION. Time effort for clinical adjustments was higher in the cast-free protocol, whereas quantity of modifications was lower, and the occlusal contact relationship was found more favourable. [J Adv Prosthodont 2021;13:351-60]
引用
收藏
页码:351 / 360
页数:10
相关论文
共 34 条
  • [1] Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review
    Ahlholm, Pekka
    Sipila, Kirsi
    Vallittu, Pekka
    Jakonen, Minna
    Kotiranta, Ulla
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (01): : 35 - 41
  • [2] Accuracy of 3-dimensional computer-aided manufactured single-tooth implant definitive casts
    Buda, Michele
    Bratos, Manuel
    Sorensen, John A.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (06) : 913 - 918
  • [3] Digital vs Conventional Workflow for Screw-Retained Single-Implant Crowns: A Comparison of Key Considerations
    Di Fiore, Adolfo
    Vigolo, Paolo
    Graiff, Lorenzo
    Stellini, Edoardo
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (06) : 577 - 579
  • [4] Dupagne L, 2021, J PROSTHET DENT, V0022, P00076
  • [5] Evaluation of the Accuracy of Digital Impressions Obtained from Intraoral and Extraoral Dental Scanners with Different CAD/CAM Scanning Technologies: An In Vitro Study
    Ellakany, Passent
    El Tantawi, Maha
    Mahrous, Amr A.
    Al-Harbi, Fahad
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (04): : 314 - 319
  • [6] Accuracy evaluation of complete-arch models manufactured by three different 3D printing technologies: a three-dimensional analysis
    Emir, Faruk
    Ayyildiz, Simel
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (03) : 365 - 370
  • [7] Ender A, 2019, INT J COMPUT DENT, V22, P11
  • [8] Hamm J, 2020, INT J COMPUT DENT, V23, P49
  • [9] IN VIVO AND IN VITRO COMPARISON OF INTERNAL AND MARGINAL FIT OF DIGITAL AND CONVENTIONAL IMPRESSIONS FOR FULL-COVERAGE FIXED RESTORATIONS: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Hasanzade, Mahya
    Shirani, Mohammadjavad
    Afrashtehfar, Kelvin, I
    Naseri, Parisa
    Alikhasi, Marzieh
    [J]. JOURNAL OF EVIDENCE-BASED DENTAL PRACTICE, 2019, 19 (03) : 236 - 254
  • [10] The Influence of Torque Tightening on the Position Stability of the Abutment in Conical Implant-Abutment Connections
    Hogg, Wiebke Semper
    Zulauf, Kris
    Mehrhof, Juergen
    Nelson, Katja
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (05) : 538 - 541