A Matched-Pulse Approach for Soft-Fault Detection in Complex Wire Networks

被引:32
作者
Abboud, Layane [1 ]
Cozza, Andrea [1 ]
Pichon, Lionel [2 ]
机构
[1] Univ Paris 11, CNRS, UMR 8506, Dept Rech Electromagnetisme,Lab Signaux & Syst,SU, F-91192 Gif Sur Yvette, France
[2] Univ Paris 11, CNRS, UMR 8507, Lab Genie Elect Paris,SUPELEC, F-91192 Gif Sur Yvette, France
关键词
Complex networks; fault detection; soft faults; time-domain reflectometry (TDR); TIME-DOMAIN REFLECTOMETRY; SHIELDED CABLES; LOCATION; REVERSAL; LOCALIZATION;
D O I
10.1109/TIM.2012.2187246
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The idea of matched-pulse (MP) reflectometry is here introduced as an improvement for fault-detection techniques in wire networks. As opposed to existing reflectometry methods, the testing signal is network dependent and self-adaptive and designed in a way as to maximize the probability of detection of an echo associated to an eventual fault. The detection performance of this novel technique is investigated by means of a mathematical analysis comparing it to standard time-domain reflectometry (TDR) methods. It is proven that the more complex the network, the better the performance that the MP approach will provide. This is opposed to common understanding, as standard TDR techniques yield degrading detection probabilities in the case of the complex networks. Furthermore, the MP approach is shown to be particularly interesting for soft-fault detection, as it provides an improved performance as soon as the fault is weakly reflective. Our findings show that the MP approach is expected to bring a substantial improvement in the likelihood of properly detecting faults in configurations that are deemed critical for standard reflectometry techniques, particularly when dealing with noisy networks under test. Experimental results measured on coaxial complex networks support these claims.
引用
收藏
页码:1719 / 1732
页数:14
相关论文
共 27 条
  • [1] Abboud L., 2009, P 9 INT C ITS TEL LI
  • [2] Abboud L., 2010, P 1 INT C COMPL SYST, P161
  • [3] [Anonymous], 2000, REV FED PROGR WIR SY
  • [4] Detection and localization of defects in shielded cables by time-domain measurements with UWB pulse injection and clean algorithm postprocessing
    Buccella, C
    Feliziani, M
    Manzi, G
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2004, 46 (04) : 597 - 605
  • [5] Fault location on shielded cables: Electromagnetic modelling and improved measurement data processing
    Cerri, G
    De Leo, R
    Della Nebbia, L
    Pennesi, S
    Primiani, VM
    Russo, P
    [J]. IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2005, 152 (05) : 217 - 226
  • [6] Taking advantage of multiple scattering to communicate with time-reversal antennas
    Derode, A
    Tourin, A
    de Rosny, J
    Tanter, M
    Yon, S
    Fink, M
    [J]. PHYSICAL REVIEW LETTERS, 2003, 90 (01) : 014301/1 - 014301/4
  • [7] ROBUST ACOUSTIC TIME-REVERSAL WITH HIGH-ORDER MULTIPLE-SCATTERING
    DERODE, A
    ROUX, P
    FINK, M
    [J]. PHYSICAL REVIEW LETTERS, 1995, 75 (23) : 4206 - 4209
  • [8] Derode A., 2001, PHYS REV E, V64, P36606
  • [9] Dunn P.F., 2010, MEASUREMENT DATA ANA, V2nd
  • [10] TIME-REVERSAL OF ULTRASONIC FIELDS .1. BASIC PRINCIPLES
    FINK, M
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (05) : 555 - 566