Sensitive hybrid femtosecond/picosecond vibrational coherent anti-Stokes Raman scattering thermometry using optimized probe time delays

被引:12
|
作者
Zhao, Huijie [1 ]
Tian, Ziyang [1 ]
Wu, Tao [1 ]
Li, Yan [1 ]
Wei, Haoyun [1 ]
机构
[1] Tsinghua Univ, Dept Precis Instrument, State Key Lab Precis Measurement Technol & Instru, Beijing 100084, Peoples R China
基金
国家重点研发计划;
关键词
TEMPERATURE-MEASUREMENTS; CARS THERMOMETRY; PULSE; SHOT; NITROGEN; N-2;
D O I
10.1063/1.5140212
中图分类号
O59 [应用物理学];
学科分类号
摘要
We propose a method that utilizes optimized probe time delays of 10-35 ps in hybrid femtosecond/picosecond (fs/ps) vibrational coherent anti-Stokes Raman scattering thermometry and obtains maximum temperature sensitivity from 300 to 2500K. The relationship between temperature sensitivity and the optimal probe time delay can be approximated by a power function. Sensitive measurements at flame temperatures (1700-2100K) using optimal time delays are performed in further experiments where the Raman coherence of nitrogen molecules is excited by 35-fs pump and Stokes pulses and probed with a spectrally narrow pulse generated from a 4-f pulse shaper. Temperature results at optimal time delays exhibit state-of-the-art accuracy and superior uncertainty, demonstrating its capability to achieve sensitive measurements.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Single-shot ultrafast coherent anti-Stokes Raman scattering of vibrational/rotational nonequilibrium
    Dedic, Chloe E.
    Meyer, Terrence R.
    Michael, James B.
    OPTICA, 2017, 4 (05): : 563 - 570
  • [22] Saturation of vibrational coherent anti-Stokes Raman scattering mediated by saturation of the rotational Raman transition
    Patnaik, Anil K.
    Roy, Sukesh
    Gord, James R.
    PHYSICAL REVIEW A, 2013, 87 (04):
  • [23] Suppression of Raman-resonant interferences in rotational coherent anti-Stokes Raman spectroscopy using time-delayed picosecond probe pulses
    Seeger, Thomas
    Kiefer, Johannes
    Gao, Yi
    Patterson, Brian D.
    Kliewer, Christopher J.
    Settersten, Thomas B.
    OPTICS LETTERS, 2010, 35 (12) : 2040 - 2042
  • [24] Three-beam rotational coherent anti-Stokes Raman spectroscopy thermometry in scattering environments
    Richardson, Daniel R.
    Kearney, Sean P.
    Guildenbecher, Daniel R.
    APPLIED OPTICS, 2020, 59 (27) : 8293 - 8301
  • [25] Rotational hydrogen thermometry by hybrid fs/ps coherent anti-Stokes Raman scattering in the plume of a burning metalized propellant
    Retter, Jonathan E.
    Richardson, Daniel R.
    Kearney, Sean P.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2020, 126 (05):
  • [26] Picosecond time-resolved pure-rotational coherent anti-Stokes Raman spectroscopy for N2 thermometry
    Seeger, Thomas
    Kiefer, Johannes
    Leipertz, Alfred
    Patterson, Brian D.
    Kliewer, Christopher J.
    Settersten, Thomas B.
    OPTICS LETTERS, 2009, 34 (23) : 3755 - 3757
  • [27] Coherent anti-Stokes Raman scattering: Spectroscopy and microscopy
    El-Diasty, Fouad
    VIBRATIONAL SPECTROSCOPY, 2011, 55 (01) : 1 - 37
  • [28] Combined spontaneous Stokes and coherent anti-Stokes Raman scattering spectroscopy
    Becker, Karina
    Kiefer, Johannes
    APPLIED PHYSICS B-LASERS AND OPTICS, 2016, 122 (05):
  • [29] Time-and frequency-dependent model of time-resolved coherent anti-Stokes Raman scattering (CARS) with a picosecond-duration probe pulse
    Stauffer, Hans U.
    Miller, Joseph D.
    Slipchenko, Mikhail N.
    Meyer, Terrence R.
    Prince, Benjamin D.
    Roy, Sukesh
    Gord, James R.
    JOURNAL OF CHEMICAL PHYSICS, 2014, 140 (02):
  • [30] Dual-pump coherent anti-Stokes Raman scattering thermometry in a sooting turbulent pool fire
    Kearney, Sean P.
    Frederickson, Kraig
    Grasser, Thomas W.
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2009, 32 : 871 - 878