Quantification of SPECT myocardial perfusion images: Methodology and validation of the Yale-CQ method

被引:57
作者
Liu, YH
Sinusas, AJ
DeMan, P
Zaret, BL
Wackers, FJT
机构
[1] Yale Univ, Sch Med, Dept Internal Med, Sect Cardiovasc Med, New Haven, CT 06520 USA
[2] Yale Univ, Sch Med, Dept Diagnost Radiol, New Haven, CT 06520 USA
关键词
SPECT; quantification; circumferential profile; perfusion defect;
D O I
10.1016/S1071-3581(99)90080-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Quantification of single photon emission computed tomography (SPECT) images is important for reproducible and accurate image interpretation. In addition, SPECT quantification provides important prognostic information. The purpose of this study was to validate the Yale circumferential quantification (Yale-CQ) method in phantom studies. Methods. Myocardial perfusion defects of varying extent and severities were simulated in a cardiac phantom with fillable defect inserts. Forty-five different phantom configurations simulated 45 different myocardial perfusion defect sizes, ranging from 1.6% to 32% of the cardiac phantom volume, Automatic processing was compared with manual processing In the phantom SPECT studies. Results. The automatic Yale-CQ algorithm performed well in all phantom studies. Compared with manual processing, the mean absolute error for automatically determined center of short axis slices a as 0.27 pixel in the x direction, 0.45 pixel in the y direction, and 0.15 pixel in radius. Quantification of phantom defects with the Yale-CQ method correlated well with actual defect sizes (R = 0.99), but there was a systematic underestimation (mean en or = -7.9 %). With derived correction factors the overall correlation between 45 phantom defects and actual defect sizes was excellent, and the estimation error was significantly improved (R = 0.98, mean error = -0.82 % for manual method and -0.95 do for automatic method). Conclusion. The automatic processing algorithm performs well for the phantom studies. Myocardial perfusion abnormalities can he quantified accurately by use of the Yale-CQ method. Quantified SPECT defect size can be expressed as a percentage of the left ventricle.
引用
收藏
页码:190 / 203
页数:14
相关论文
共 38 条
[1]  
ALAZRAKI NP, 1994, J NUCL MED, V35, P1237
[2]   PATHOPHYSIOLOGY OF CARDIOGENIC-SHOCK - QUANTIFICATION OF MYOCARDIAL NECROSIS, CLINICAL, PATHOLOGIC AND ELECTROCARDIOGRAPHIC CORRELATIONS [J].
ALONSO, DR ;
SCHEIDT, S ;
POST, M ;
KILLIP, T .
CIRCULATION, 1973, 48 (03) :588-596
[3]  
AMAZIGO JC, 1980, ADV CALCULUS, P1
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
BUROW RD, 1979, J NUCL MED, V20, P771
[6]  
Cooke C D, 1993, Am J Card Imaging, V7, P179
[7]   Prognostic value of exercise Tl-201 tomography in patients treated with thrombolytic therapy during acute myocardial infarction [J].
Dakik, HA ;
Mahmarian, JJ ;
Kimball, KT ;
Koutelou, MG ;
Medrano, R ;
Verani, MS .
CIRCULATION, 1996, 94 (11) :2735-2742
[8]  
DeGroot M. H., 1986, PROBABILITY STAT, P209
[9]   3-DIMENSIONAL TECHNIQUES AND ARTIFICIAL-INTELLIGENCE IN TL-201 CARDIAC IMAGING [J].
DEPUEY, EG ;
GARCIA, EV ;
EZQUERRA, NF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (06) :1161-1168
[10]  
EISNER RL, 1988, J NUCL MED, V29, P1901