Clinical and radiological outcomes of 40 cases of SLAC and SNAC wrist treated by four-corner arthrodesis with locking plate

被引:9
作者
Rimokh, J. [1 ]
Benazech, B. [1 ]
Lebeau, N. [2 ]
Haddad, B. [1 ]
Moughabghab, M. [2 ]
David, E. [1 ]
机构
[1] Univ Hosp Ctr Amiens, Chirurg Orthoped, Ave Rene Laennec, F-80480 Salouel, France
[2] St Quentin Hosp Ctr, Ave Michel Hosp, F-02321 St Quentin en Yvelines, France
关键词
Four-corner arthrodesis; Locking plate; SLAC wrist; SNAC wrist; Wrist; PROXIMAL ROW CARPECTOMY; ADVANCED COLLAPSE WRIST; CIRCULAR PLATE; FUSION; FIXATION; COMPLICATIONS; MOTION; GRAFT; VS;
D O I
10.1016/j.hansur.2019.10.196
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The treatment of scapholunate advanced collapse (SLAC) and scaphoid nonunion advanced collapse (SNAC) wrist varies. No clear consensus exists on surgical indications. Scaphoid excision and four-corner arthrodesis with locking plate is one of preferred treatments for these lesions. The purpose of this study was to assess the clinical and radiological outcomes of locking plates for treating SNAC and SLAC wrist after a mean follow-up of 5 years and to compare these outcomes with the results reported in the literature. A retrospective study was conducted in two hospitals, involving 40 patients who underwent scaphoid excision and four-corner arthrodesis with locking plate between January 2006 and September 2016. All patients were reviewed as outpatients with clinical and radiographic measurements. At the last follow-up, the mean pain level on visual analog scale (VAS) was 2.5/10 [0-7] (SD: 1.7). Patients had a mean flexion of 46% and a mean extension of 46% compared to the contralateral side. An 18% gain was observed in grip strength. The mean postoperative QuickDASH score was 30 [0-57] (SD: 15.3). Seventy percent of patients were satisfied with the operation. Complete (all four joint interfaces) joint space fusion was achieved in 55% of patients. Only one patient (2.5%) had no joint fusion. The joint between the lunate and the capitate was fused in 38 patients (95%). Nine patients suffered complications; eight of them required surgical revision (20%). Four-corner arthrodesis with locking plate is a valuable surgical technique for treating SLAC and SNAC wrist because it preserve satisfactory range of motion and grip strength (64% compared to the non-operated side), maintains the height of the carpus and prevents the premature appearance of radiocarpal osteoarthritis, as long as the technical challenges of this procedure are mastered. (C) 2019 Published by Elsevier Masson SAS on behalf of SFCM.
引用
收藏
页码:36 / 40
页数:5
相关论文
共 27 条
  • [1] Development of the QuickDASH: Comparison of three item-reduction approaches
    Beaton, DE
    Wright, JG
    Katz, JN
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (05) : 1038 - 1046
  • [2] High Fusion Rates with Circular Plate Fixation for Four-corner Arthrodesis of the Wrist
    Bedford, Ben
    Yang, S. Steven
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) : 163 - 168
  • [3] Reproducibility of X-rays and CT arthrography in SLAC, SNAC, SCAC wrists
    Belhaouane, R.
    Lebeau, N.
    Maes-Clavier, C.
    Hustin, C.
    Krief, E.
    Bonnaire, B.
    Warin, M.
    Rotari, V.
    David, E.
    [J]. HAND SURGERY & REHABILITATION, 2016, 35 (06) : 393 - 400
  • [4] NEW DORSAL CAPSULOTOMY FOR THE SURGICAL EXPOSURE OF THE WRIST
    BERGER, RA
    BISHOP, AT
    BETTINGER, PC
    [J]. ANNALS OF PLASTIC SURGERY, 1995, 35 (01) : 54 - 59
  • [5] A comparison of two indices for ulnar translation and carpal height in the rheumatoid wrist
    Borisch, N
    Lerch, K
    Grifka, J
    Haussmann, P
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2004, 29B (02) : 144 - 147
  • [6] A prospective outcomes study of four-corner wrist arthrodesis using a circular limited wrist fusion plate for stage II scapholunate advanced collapse wrist deformity
    Chung, Kevin C.
    Watt, Andrew J.
    Kotsis, Sandra V.
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2006, 118 (02) : 433 - 442
  • [7] Four-corner arthrodesis: Influence of the position of the lunate on postoperative wrist motion: A cadaveric study
    De Carli, Pablo
    Donndorff, Agustin G.
    Alfie, Veronica A.
    Boretto, Jorge G.
    Lopez Ovenza, Joan M.
    Gallucci, Gerardo L.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (09): : 1356 - 1362
  • [8] Radius Core Decompression for Kienbock Disease Stage IIIA: Outcomes at 13 Years Follow-Up
    De Carli, Pablo
    Ernesto Zaidenberg, Ezequiel
    Alfie, Veronica
    Donndorff, Agustin
    Guillermo Boretto, Jorge
    Luis Gallucci, Gerardo
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (09): : 752.e1 - 752.e6
  • [9] Garbuio P, 1996, Ann Chir Main Memb Super, V15, P226, DOI 10.1016/S0753-9053(96)80031-7
  • [10] Four-corner fusion: comparison of patient satisfaction and functional outcome of conventional K-wire technique vs. a new locking plate
    Hernekamp, J. F.
    Reinecke, A.
    Neubrech, F.
    Bickert, B.
    Kneser, U.
    Kremer, T.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (04) : 571 - 578