Effects of Abutment Screw Coating on Implant Preload

被引:74
作者
Park, Jae-Kyoung [1 ]
Choi, Jin-Uk [1 ]
Jeon, Young-Chan [1 ]
Choi, Kyung-Soo [1 ]
Jeong, Chang-Mo [1 ]
机构
[1] Pusan Natl Univ, Dept Prosthodont, Sch Dent, Pusan 602, South Korea
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2010年 / 19卷 / 06期
关键词
Screw preload; tungsten carbide carbon coating; implant connection systems; DENTAL IMPLANTS; OSSEOINTEGRATION; COMPLICATIONS; RESTORATIONS; INTERFACE; DESIGN;
D O I
10.1111/j.1532-849X.2010.00595.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of the present study was to investigate the effects of tungsten carbide carbon (WC/CTa) screw surface coating on abutment screw preload in three implant connection systems in comparison to noncoated titanium alloy (Ta) screws. Materials and Methods: Preload of WC/CTa abutment screws was compared to noncoated Ta screws in three implant connection systems. The differences in preloads were measured in tightening rotational angle, compression force, initial screw removal torque, and postload screw removal torque after 1 million cyclic loads. Preload loss percent was calculated to determine the efficacy of maintaining the preload of two abutment screw types in relation to implant connection systems. Results: WC/CTa screws provided 10. higher tightening rotational angle than Ta screws in all three connection systems. This difference was statistically significant (p < 0.05). External-hex butt joint implant connections had a higher compression force than the two internal conical implant connections. WC/CTa screws provided a statistically significantly higher compression force than Ta screws in all three implant connections (p < 0.05). Ta screws required statistically higher removal torque than WC/CTa screws in all three implant connections (p < 0.05); however, Ta screws needed statistically lower postload removal torque than WC/CTa screws in all three implant connections (p < 0.05). Ta screws had a statistically higher preload loss percent than WC/CTa screws in all three implant connections (p < 0.05), indicating that WC/CTa screws were superior in maintaining the preload than Ta screws. Conclusions: Within the limits of present study, the following conclusions were made: (1) WC/CTa screws provided higher preload than noncoated Ta screws in all three implant connection systems. (2) The initial removal torque for Ta screws required higher force than WC/CTa screws, whereas postload removal torque for Ta screws was lower than WC/CTa screws. Calculated Ta screw preload loss percent was higher than for WC/CTa screws, suggesting that WC/CTa screws were more effective in maintaining the preload than Ta screws. (3) Internal conical connections were more effective in maintaining the screw preload in cyclic loads than external-hex butt joint connections.
引用
收藏
页码:458 / 464
页数:7
相关论文
共 28 条
[1]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[2]  
ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P347
[3]  
ANDERSSON B, 1992, International Journal of Oral and Maxillofacial Implants, V7, P105
[4]   COMPARATIVE-STUDY OF ANTIROTATIONAL SINGLE TOOTH ABUTMENTS [J].
BALFOUR, A ;
OBRIEN, GR .
JOURNAL OF PROSTHETIC DENTISTRY, 1995, 73 (01) :36-43
[5]   REPLACEMENT OF MAXILLARY AND MANDIBULAR MOLARS WITH SINGLE ENDOSSEOUS IMPLANT RESTORATIONS - A RETROSPECTIVE STUDY [J].
BECKER, W ;
BECKER, BE .
JOURNAL OF PROSTHETIC DENTISTRY, 1995, 74 (01) :51-55
[6]   OSSEOINTEGRATION AND ITS EXPERIMENTAL BACKGROUND [J].
BRANEMARK, PI .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (03) :399-410
[7]   TIGHTENING CHARACTERISTICS FOR SCREWED JOINTS IN OSSEOINTEGRATED DENTAL IMPLANTS [J].
BURGUETE, RL ;
JOHNS, RB ;
KING, T ;
PATTERSON, EA .
JOURNAL OF PROSTHETIC DENTISTRY, 1994, 71 (06) :592-599
[8]  
Drago CJ, 2003, INT J ORAL MAX IMPL, V18, P273
[9]   Clinical complications with implants and implant prostheses [J].
Goodacre, CJ ;
Bernal, G ;
Rungcharassaeng, K ;
Kan, JYK .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (02) :121-132
[10]  
Griffith H.T., 1987, TORQUE TENSIONING 10