Cochlear implant speech processor frequency allocations may influence pitch perception

被引:44
作者
Reiss, Lina A. J. [1 ]
Gantz, Bruce J. [2 ]
Turner, Christopher W. [1 ]
机构
[1] Univ Iowa, Dept Speech Pathol & Audiol, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Otolaryngol Head & Neck Surg, Iowa City, IA 52242 USA
关键词
cochlear implants; hybrid; pitch; residual hearing;
D O I
10.1097/mao.0b013e31815aedf4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To investigate the effects of assigning cochlear implant speech processor frequencies normally associated with more apical cochlear locations to the shallow insertion depths of the Iowa/Nucleus Hybrid electrode. Study Design: Subjects using the Hybrid implant for more than I year were tested on speech recognition with Consonant-Nucleus-Consonant words and consonant stimuli. Pitch sensations of individual electrodes were also measured electrically through the implant and acoustically in the contralateral ear. Results: Most subjects showed large improvements in speech recognition within 12 months after implantation. Furthermore, after longer periods of 24-plus months, some individuals were able to achieve high levels of consonant discrimination with electric-only processing comparable to long-electrode patients with deeper electrode insertions. Pitch perceptions obtained from individual electrodes in these subjects were closer to the frequency map assigned an electrode than the place-frequency predicted from cochlear location. Conclusion: These results suggest that over time, pitch sensations may be determined more by the implant map than by cochlear location. In other words, the brain may adapt to Spectral mismatches by remapping pitch. Furthermore, patients can perform well with shifted frequency allocations for speech recognition. The successful application of shifted frequency allocations also supports the idea of shallower insertions and greater preservation of residual hearing for all cochlear implants, regardless of the patient's frequency range of usable residual hearing.
引用
收藏
页码:160 / 167
页数:8
相关论文
共 15 条
[1]   Frequency-place compression and expansion in cochlear implant listeners [J].
Baskent, D ;
Shannon, RV .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 116 (05) :3130-3140
[2]   Simulating the effect of cochlear-implant electrode insertion depth on speech understanding [J].
Dorman, MF ;
Loizou, PC ;
Rainey, D .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 102 (05) :2993-2996
[3]   Simulations of tonotopically mapped speech processors for cochlear implant electrodes varying in insertion depth [J].
Faulkner, A ;
Rosen, S ;
Stanton, D .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 113 (02) :1073-1080
[4]   Auditory training with spectrally shifted speech: Implications for cochlear implant patient auditory rehabilitation [J].
Fu, QJ ;
Nogaki, G ;
Galvin, JJ .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2005, 6 (02) :180-189
[5]   Effects of electrode configuration and frequency allocation on vowel recognition with the nucleus-22 cochlear implant [J].
Fu, QJ ;
Shannon, RV .
EAR AND HEARING, 1999, 20 (04) :332-344
[6]   Recognition of spectrally degraded and frequency-shifted vowels in acoustic and electric hearing [J].
Fu, QJ ;
Shannon, RV .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 105 (03) :1889-1900
[7]   Combining acoustic and electrical hearing [J].
Gantz, BJ ;
Turner, CW .
LARYNGOSCOPE, 2003, 113 (10) :1726-1730
[8]  
Gantz Bruce J, 2006, Audiol Neurootol, V11 Suppl 1, P63, DOI 10.1159/000095616
[9]  
Gfeller Kate E, 2006, Audiol Neurootol, V11 Suppl 1, P12, DOI 10.1159/000095608
[10]   A COCHLEAR FREQUENCY-POSITION FUNCTION FOR SEVERAL SPECIES - 29 YEARS LATER [J].
GREENWOOD, DD .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 87 (06) :2592-2605