Evaluation of Marginal and Internal Fit of a CAD/CAM Monolithic Zirconia-Reinforced Lithium Silicate Porcelain Laminate Veneer System

被引:11
作者
Baig, Mirza Rustum [1 ]
Akbar, Aqdar A. [2 ]
Sabti, Mohammad Y. [2 ]
Behbehani, Zahra [3 ]
机构
[1] Kuwait Univ, Fac Dent, Dept Restorat Sci Prosthodont, Kuwait, Kuwait
[2] Kuwait Univ, Fac Dent, Dept Gen Dent Practice, Kuwait, Kuwait
[3] Minist Hlth, Kuwait, Kuwait
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2022年 / 31卷 / 06期
关键词
Ceramic; Laminate; Veneer; Zirconia lithium silicate; Lithium disilicate; Marginal fit; Internal fit; CAD; CAM; PREPARATION DESIGN; FILM THICKNESS; CROWNS; DISCREPANCY; ADAPTATION; ACCURACY; FRACTURE; LOAD;
D O I
10.1111/jopr.13438
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To evaluate the marginal and internal fit of monolithic computer-aided design/computer-aided manufacturing (CAD/CAM) ZLS (Vita Suprinity) glass ceramic porcelain laminate veneers (PLVs), in terms of marginal and internal gap widths, in comparison to monolithic lithium disilicate (LDS) [IPS e.max CAD] CAD/CAM veneers, and, also, to analyze the effect of incisal preparation designs (butt joint and chamfer), on the marginal and internal fit accuracy. Materials and Methods Forty dental stone dies poured from impressions made of two master metal dies with different incisal preparation designs were scanned to produce digital models. Forty ceramic veneers were designed and milled using the virtual models-10 ZLS butt joint, 10 ZLS chamfer, 10 LDS butt joint, and 10 LDS chamfer. The monolithic ceramic veneers produced were then subjected to marginal and internal gap width evaluation using X-ray nano-computed tomography and computerized digital analysis (n = 10). Descriptive analyses of data were performed and the influence of "material" and "preparation design" on the marginal and internal fit of veneers was assessed using 2-way ANOVA (alpha = 0.05). Bonferroni post-hoc multiple comparison tests were used to further analyze the interactions between the material and preparation design after adjusting the alpha value by Holm-Bonferroni method (alpha = 0.01). Results Mean marginal and internal gaps for ZLS PLVs were 65 +/- 11 mu m and 112 +/- 14 mu m for butt joint, and 100 +/- 24 mu m and 100 +/- 21 mu m for chamfer, respectively. Corresponding values for LDS PLVs were 78 +/- 25 mu m and 114 +/- 17 mu m for butt joint, and 104 +/- 18 mu m and 106 +/- 7 mu m for chamfer. Marginal gap and internal gap differences between ZLS and LDS PLVs were not significant (marginal gap: F = 1.786, p = 0.190; internal gap: F = 0.807, p = 0.375). However, the preparation designs (butt joint and chamfer) differed significantly in terms of marginal gaps (F = 23.797, p = 0.000), but not internal gaps (F = 3.703; p = 0.059). Conclusions Butt joint margins produced better marginal accuracy in terms of marginal gap, compared to chamfers, for ZLS CAD/CAM laminate veneers.
引用
收藏
页码:502 / 511
页数:10
相关论文
共 50 条
[21]   Effect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns [J].
Kale, Ediz ;
Seker, Emre ;
Yilmaz, Burak ;
Ozcelik, Tuncer Burak .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (06) :890-895
[22]   Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown [J].
Ji, Min-Kyung ;
Park, Ji-Hee ;
Park, Sang-Won ;
Yun, Kwi-Dug ;
Oh, Gye-Jeong ;
Lim, Hyun-Pil .
JOURNAL OF ADVANCED PROSTHODONTICS, 2015, 7 (04) :271-277
[23]   Indirect zirconia-reinforced lithium silicate ceramic CAD/CAM restorations: Preliminary clinical results after 12 months [J].
Zimmermann, Moritz ;
Koller, Christina ;
Mehl, Albert ;
Hickel, Reinhard .
QUINTESSENCE INTERNATIONAL, 2017, 48 (01) :19-25
[24]   Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns [J].
Pak, Hyun-Soon ;
Han, Jung-Suk ;
Lee, Jai-Bong ;
Kim, Sung-Hun ;
Yang, Jae-Ho .
JOURNAL OF ADVANCED PROSTHODONTICS, 2010, 2 (02) :33-38
[25]   MARGINAL AND INTERNAL FIT OF PARTIAL-RETAINER CAD/CAM ZIRCONIA FIXED DENTAL PROSTHESES [J].
Candea, Adrian ;
Jivanescu, Anca ;
Leretter, Marius ;
Rominu, Mihai .
PROCEEDINGS OF THE ROMANIAN ACADEMY SERIES A-MATHEMATICS PHYSICS TECHNICAL SCIENCES INFORMATION SCIENCE, 2017, 18 (04) :345-352
[26]   Evaluation of the marginal and internal gaps of partially crystallized versus fully crystallized zirconia-reinforced lithium silicate CAD-CAM crowns: An in vitro comparison of the silicone replica technique, direct view, and 3-dimensional superimposition analysis [J].
El-Ashkar, Alaa ;
Taymour, Maha ;
El-Tannir, Adel .
JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (05) :769-776
[27]   In Vitro Study of Comparative Evaluation of Marginal and Internal Fit between Heat-Pressed and CAD-CAM Monolithic Glass-Ceramic Restorations after Thermal Aging [J].
Vasiliu, Roxana-Diana ;
Porojan, Sorin Daniel ;
Porojan, Liliana .
MATERIALS, 2020, 13 (19)
[28]   The Influence of Ferrule Design and Pulpal Extensions on the Accuracy of Fit and the Fracture Resistance of Zirconia-Reinforced Lithium Silicate Endocrowns [J].
Saker, Samah ;
Alqutaibi, Ahmed Yaseen ;
Alghauli, Mohammed Ahmed ;
Hashem, Danya ;
Borzangy, Sary ;
Farghal, Ahmed E. ;
Alnazzawi, Ahmad A. ;
Ainoosah, Sultan ;
Abdelaziz, Mohammed H. .
MATERIALS, 2024, 17 (06)
[29]   Comparison of marginal adaptation and internal fit of monolithic lithium disilicate crowns produced by 4 different CAD/CAM systems [J].
Brunna Mota Ferrairo ;
Fernanda Furtado Piras ;
Feranda Ferruzzi Lima ;
Heitor Marques Honório ;
Marco Antonio Hungaro Duarte ;
Ana Flávia Sanches Borges ;
José Henrique Rubo .
Clinical Oral Investigations, 2021, 25 :2029-2036
[30]   Evaluation of the marginal and internal fit of CAD/CAM crowns designed using three different dental CAD programs: a 3-dimensional digital analysis study [J].
Farah, Ra'fat, I ;
Alresheedi, Bandar .
CLINICAL ORAL INVESTIGATIONS, 2023, 27 (01) :263-271