Evaluation of Marginal and Internal Fit of a CAD/CAM Monolithic Zirconia-Reinforced Lithium Silicate Porcelain Laminate Veneer System

被引:11
作者
Baig, Mirza Rustum [1 ]
Akbar, Aqdar A. [2 ]
Sabti, Mohammad Y. [2 ]
Behbehani, Zahra [3 ]
机构
[1] Kuwait Univ, Fac Dent, Dept Restorat Sci Prosthodont, Kuwait, Kuwait
[2] Kuwait Univ, Fac Dent, Dept Gen Dent Practice, Kuwait, Kuwait
[3] Minist Hlth, Kuwait, Kuwait
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2022年 / 31卷 / 06期
关键词
Ceramic; Laminate; Veneer; Zirconia lithium silicate; Lithium disilicate; Marginal fit; Internal fit; CAD; CAM; PREPARATION DESIGN; FILM THICKNESS; CROWNS; DISCREPANCY; ADAPTATION; ACCURACY; FRACTURE; LOAD;
D O I
10.1111/jopr.13438
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To evaluate the marginal and internal fit of monolithic computer-aided design/computer-aided manufacturing (CAD/CAM) ZLS (Vita Suprinity) glass ceramic porcelain laminate veneers (PLVs), in terms of marginal and internal gap widths, in comparison to monolithic lithium disilicate (LDS) [IPS e.max CAD] CAD/CAM veneers, and, also, to analyze the effect of incisal preparation designs (butt joint and chamfer), on the marginal and internal fit accuracy. Materials and Methods Forty dental stone dies poured from impressions made of two master metal dies with different incisal preparation designs were scanned to produce digital models. Forty ceramic veneers were designed and milled using the virtual models-10 ZLS butt joint, 10 ZLS chamfer, 10 LDS butt joint, and 10 LDS chamfer. The monolithic ceramic veneers produced were then subjected to marginal and internal gap width evaluation using X-ray nano-computed tomography and computerized digital analysis (n = 10). Descriptive analyses of data were performed and the influence of "material" and "preparation design" on the marginal and internal fit of veneers was assessed using 2-way ANOVA (alpha = 0.05). Bonferroni post-hoc multiple comparison tests were used to further analyze the interactions between the material and preparation design after adjusting the alpha value by Holm-Bonferroni method (alpha = 0.01). Results Mean marginal and internal gaps for ZLS PLVs were 65 +/- 11 mu m and 112 +/- 14 mu m for butt joint, and 100 +/- 24 mu m and 100 +/- 21 mu m for chamfer, respectively. Corresponding values for LDS PLVs were 78 +/- 25 mu m and 114 +/- 17 mu m for butt joint, and 104 +/- 18 mu m and 106 +/- 7 mu m for chamfer. Marginal gap and internal gap differences between ZLS and LDS PLVs were not significant (marginal gap: F = 1.786, p = 0.190; internal gap: F = 0.807, p = 0.375). However, the preparation designs (butt joint and chamfer) differed significantly in terms of marginal gaps (F = 23.797, p = 0.000), but not internal gaps (F = 3.703; p = 0.059). Conclusions Butt joint margins produced better marginal accuracy in terms of marginal gap, compared to chamfers, for ZLS CAD/CAM laminate veneers.
引用
收藏
页码:502 / 511
页数:10
相关论文
共 50 条
  • [11] Response of pre-crystallized CAD/CAM zirconia-reinforced lithium silicate glass ceramic to cyclic nanoindentation
    Springall, Gabriella A. C.
    Yin, Ling
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 92 : 58 - 70
  • [12] The Influence of Three Different Digital Cement Spacers on the Marginal Gap Adaptation of Zirconia-Reinforced Lithium Silicate Crowns Fabricated by CAD-CAM System
    Ben-Izhack, Gil
    Shely, Asaf
    Naishlos, Sarit
    Glikman, Ari
    Frishman, Liad
    Meirowitz, Avi
    Dolev, Eran
    APPLIED SCIENCES-BASEL, 2021, 11 (22):
  • [13] Effect of total occlusal convergence on fit and fracture resistance of zirconia-reinforced lithium silicate crowns
    Alammari, Manal Rahma
    Abdelnabi, Mohamed Hussein
    Swelem, Amal Ali
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2019, 11 : 1 - 8
  • [14] In vitro evaluation of the internal and marginal misfit of CAD/CAM zirconia copings
    Lins, Leonardo
    Bemfica, Vinicius
    Queiroz, Celso
    Canabarro, Antonio
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (03) : 205 - 211
  • [15] Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings
    Beuer, Florian
    Aggstaller, Hans
    Richter, Juliane
    Edelhoff, Daniel
    Gernet, Wolfgang
    QUINTESSENCE INTERNATIONAL, 2009, 40 (03): : 243 - 250
  • [16] SEM Evaluation of the Marginal Gap of Zirconia-Reinforced Lithium Silicate Full Crowns and the Effect of Post Crystallization: An In Vitro Study
    Shely, Asaf
    Lugassy, Diva
    Anufriev, Maxim
    Nissan, Joseph
    Rauchwerger, Olisya
    Ben-Izhack, Gil
    DENTISTRY JOURNAL, 2024, 12 (03)
  • [17] Comparative analysis of endocrown fracture resistance and marginal adaptation: CAD/CAM technology using lithium disilicate vs. zirconia-reinforced lithium silicate ceramics
    Jalalian, Ezatollah
    Zarbakhsh, Arash
    Khorshidi, Sotude
    Golalipour, Shaghayegh
    Mohammadnasl, Sara
    Sayyari, Maryam
    SAUDI DENTAL JOURNAL, 2024, 36 (02) : 353 - 358
  • [18] Marginal adaptation of zirconia-reinforced lithium silicate overlays with different preparation designs
    Falahchai, Mehran
    Hemmati, Yasamin Babaee
    Asli, Hamid Neshandar
    Asli, Marzieh Neshandar
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2020, 32 (08) : 823 - 830
  • [19] Misfit and fracture load of implant-supported monolithic crowns in zirconia-reinforced lithium silicate
    Gomes, Rafael Soares
    Carvalho de Souza, Caroline Mathias
    Pedroso Bergamo, Edmara Tatiely
    Bordin, Dimorvan
    Del Bel Cury, Altair Antoninha
    JOURNAL OF APPLIED ORAL SCIENCE, 2017, 25 (03) : 282 - 289
  • [20] Nano-scale mechanical behavior of pre-crystallized CAD/CAM zirconia-reinforced lithium silicate glass ceramic
    Springall, Gabriella A. C.
    Yin, Ling
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 82 : 35 - 44