Evaluation of Marginal and Internal Fit of a CAD/CAM Monolithic Zirconia-Reinforced Lithium Silicate Porcelain Laminate Veneer System

被引:11
作者
Baig, Mirza Rustum [1 ]
Akbar, Aqdar A. [2 ]
Sabti, Mohammad Y. [2 ]
Behbehani, Zahra [3 ]
机构
[1] Kuwait Univ, Fac Dent, Dept Restorat Sci Prosthodont, Kuwait, Kuwait
[2] Kuwait Univ, Fac Dent, Dept Gen Dent Practice, Kuwait, Kuwait
[3] Minist Hlth, Kuwait, Kuwait
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2022年 / 31卷 / 06期
关键词
Ceramic; Laminate; Veneer; Zirconia lithium silicate; Lithium disilicate; Marginal fit; Internal fit; CAD; CAM; PREPARATION DESIGN; FILM THICKNESS; CROWNS; DISCREPANCY; ADAPTATION; ACCURACY; FRACTURE; LOAD;
D O I
10.1111/jopr.13438
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To evaluate the marginal and internal fit of monolithic computer-aided design/computer-aided manufacturing (CAD/CAM) ZLS (Vita Suprinity) glass ceramic porcelain laminate veneers (PLVs), in terms of marginal and internal gap widths, in comparison to monolithic lithium disilicate (LDS) [IPS e.max CAD] CAD/CAM veneers, and, also, to analyze the effect of incisal preparation designs (butt joint and chamfer), on the marginal and internal fit accuracy. Materials and Methods Forty dental stone dies poured from impressions made of two master metal dies with different incisal preparation designs were scanned to produce digital models. Forty ceramic veneers were designed and milled using the virtual models-10 ZLS butt joint, 10 ZLS chamfer, 10 LDS butt joint, and 10 LDS chamfer. The monolithic ceramic veneers produced were then subjected to marginal and internal gap width evaluation using X-ray nano-computed tomography and computerized digital analysis (n = 10). Descriptive analyses of data were performed and the influence of "material" and "preparation design" on the marginal and internal fit of veneers was assessed using 2-way ANOVA (alpha = 0.05). Bonferroni post-hoc multiple comparison tests were used to further analyze the interactions between the material and preparation design after adjusting the alpha value by Holm-Bonferroni method (alpha = 0.01). Results Mean marginal and internal gaps for ZLS PLVs were 65 +/- 11 mu m and 112 +/- 14 mu m for butt joint, and 100 +/- 24 mu m and 100 +/- 21 mu m for chamfer, respectively. Corresponding values for LDS PLVs were 78 +/- 25 mu m and 114 +/- 17 mu m for butt joint, and 104 +/- 18 mu m and 106 +/- 7 mu m for chamfer. Marginal gap and internal gap differences between ZLS and LDS PLVs were not significant (marginal gap: F = 1.786, p = 0.190; internal gap: F = 0.807, p = 0.375). However, the preparation designs (butt joint and chamfer) differed significantly in terms of marginal gaps (F = 23.797, p = 0.000), but not internal gaps (F = 3.703; p = 0.059). Conclusions Butt joint margins produced better marginal accuracy in terms of marginal gap, compared to chamfers, for ZLS CAD/CAM laminate veneers.
引用
收藏
页码:502 / 511
页数:10
相关论文
共 50 条
[11]   Response of pre-crystallized CAD/CAM zirconia-reinforced lithium silicate glass ceramic to cyclic nanoindentation [J].
Springall, Gabriella A. C. ;
Yin, Ling .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 92 :58-70
[12]   The Influence of Three Different Digital Cement Spacers on the Marginal Gap Adaptation of Zirconia-Reinforced Lithium Silicate Crowns Fabricated by CAD-CAM System [J].
Ben-Izhack, Gil ;
Shely, Asaf ;
Naishlos, Sarit ;
Glikman, Ari ;
Frishman, Liad ;
Meirowitz, Avi ;
Dolev, Eran .
APPLIED SCIENCES-BASEL, 2021, 11 (22)
[13]   Effect of total occlusal convergence on fit and fracture resistance of zirconia-reinforced lithium silicate crowns [J].
Alammari, Manal Rahma ;
Abdelnabi, Mohamed Hussein ;
Swelem, Amal Ali .
CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2019, 11 :1-8
[14]   In vitro evaluation of the internal and marginal misfit of CAD/CAM zirconia copings [J].
Lins, Leonardo ;
Bemfica, Vinicius ;
Queiroz, Celso ;
Canabarro, Antonio .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (03) :205-211
[15]   Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings [J].
Beuer, Florian ;
Aggstaller, Hans ;
Richter, Juliane ;
Edelhoff, Daniel ;
Gernet, Wolfgang .
QUINTESSENCE INTERNATIONAL, 2009, 40 (03) :243-250
[16]   SEM Evaluation of the Marginal Gap of Zirconia-Reinforced Lithium Silicate Full Crowns and the Effect of Post Crystallization: An In Vitro Study [J].
Shely, Asaf ;
Lugassy, Diva ;
Anufriev, Maxim ;
Nissan, Joseph ;
Rauchwerger, Olisya ;
Ben-Izhack, Gil .
DENTISTRY JOURNAL, 2024, 12 (03)
[17]   Comparative analysis of endocrown fracture resistance and marginal adaptation: CAD/CAM technology using lithium disilicate vs. zirconia-reinforced lithium silicate ceramics [J].
Jalalian, Ezatollah ;
Zarbakhsh, Arash ;
Khorshidi, Sotude ;
Golalipour, Shaghayegh ;
Mohammadnasl, Sara ;
Sayyari, Maryam .
SAUDI DENTAL JOURNAL, 2024, 36 (02) :353-358
[18]   Marginal adaptation of zirconia-reinforced lithium silicate overlays with different preparation designs [J].
Falahchai, Mehran ;
Hemmati, Yasamin Babaee ;
Asli, Hamid Neshandar ;
Asli, Marzieh Neshandar .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2020, 32 (08) :823-830
[19]   Misfit and fracture load of implant-supported monolithic crowns in zirconia-reinforced lithium silicate [J].
Gomes, Rafael Soares ;
Carvalho de Souza, Caroline Mathias ;
Pedroso Bergamo, Edmara Tatiely ;
Bordin, Dimorvan ;
Del Bel Cury, Altair Antoninha .
JOURNAL OF APPLIED ORAL SCIENCE, 2017, 25 (03) :282-289
[20]   Nano-scale mechanical behavior of pre-crystallized CAD/CAM zirconia-reinforced lithium silicate glass ceramic [J].
Springall, Gabriella A. C. ;
Yin, Ling .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 82 :35-44