Evaluation of Marginal and Internal Fit of a CAD/CAM Monolithic Zirconia-Reinforced Lithium Silicate Porcelain Laminate Veneer System

被引:11
作者
Baig, Mirza Rustum [1 ]
Akbar, Aqdar A. [2 ]
Sabti, Mohammad Y. [2 ]
Behbehani, Zahra [3 ]
机构
[1] Kuwait Univ, Fac Dent, Dept Restorat Sci Prosthodont, Kuwait, Kuwait
[2] Kuwait Univ, Fac Dent, Dept Gen Dent Practice, Kuwait, Kuwait
[3] Minist Hlth, Kuwait, Kuwait
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2022年 / 31卷 / 06期
关键词
Ceramic; Laminate; Veneer; Zirconia lithium silicate; Lithium disilicate; Marginal fit; Internal fit; CAD; CAM; PREPARATION DESIGN; FILM THICKNESS; CROWNS; DISCREPANCY; ADAPTATION; ACCURACY; FRACTURE; LOAD;
D O I
10.1111/jopr.13438
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To evaluate the marginal and internal fit of monolithic computer-aided design/computer-aided manufacturing (CAD/CAM) ZLS (Vita Suprinity) glass ceramic porcelain laminate veneers (PLVs), in terms of marginal and internal gap widths, in comparison to monolithic lithium disilicate (LDS) [IPS e.max CAD] CAD/CAM veneers, and, also, to analyze the effect of incisal preparation designs (butt joint and chamfer), on the marginal and internal fit accuracy. Materials and Methods Forty dental stone dies poured from impressions made of two master metal dies with different incisal preparation designs were scanned to produce digital models. Forty ceramic veneers were designed and milled using the virtual models-10 ZLS butt joint, 10 ZLS chamfer, 10 LDS butt joint, and 10 LDS chamfer. The monolithic ceramic veneers produced were then subjected to marginal and internal gap width evaluation using X-ray nano-computed tomography and computerized digital analysis (n = 10). Descriptive analyses of data were performed and the influence of "material" and "preparation design" on the marginal and internal fit of veneers was assessed using 2-way ANOVA (alpha = 0.05). Bonferroni post-hoc multiple comparison tests were used to further analyze the interactions between the material and preparation design after adjusting the alpha value by Holm-Bonferroni method (alpha = 0.01). Results Mean marginal and internal gaps for ZLS PLVs were 65 +/- 11 mu m and 112 +/- 14 mu m for butt joint, and 100 +/- 24 mu m and 100 +/- 21 mu m for chamfer, respectively. Corresponding values for LDS PLVs were 78 +/- 25 mu m and 114 +/- 17 mu m for butt joint, and 104 +/- 18 mu m and 106 +/- 7 mu m for chamfer. Marginal gap and internal gap differences between ZLS and LDS PLVs were not significant (marginal gap: F = 1.786, p = 0.190; internal gap: F = 0.807, p = 0.375). However, the preparation designs (butt joint and chamfer) differed significantly in terms of marginal gaps (F = 23.797, p = 0.000), but not internal gaps (F = 3.703; p = 0.059). Conclusions Butt joint margins produced better marginal accuracy in terms of marginal gap, compared to chamfers, for ZLS CAD/CAM laminate veneers.
引用
收藏
页码:502 / 511
页数:10
相关论文
共 32 条
[1]   Internal adaptation, marginal accuracy and microleakage of a pressable versus a machinable ceramic laminate veneers [J].
Aboushelib, Moustafa Nabil ;
Elmahy, Waleed AbdelMeguid ;
Ghazy, Mohammed Hamed .
JOURNAL OF DENTISTRY, 2012, 40 (08) :670-677
[2]   A comparison of the marginal and internal fit of porcelain laminate veneers fabricated by pressing and CAD-CAM milling and cemented with 2 different resin cements [J].
Al-Dwairi, Ziad N. ;
Alkhatatbeh, Rana M. ;
Baba, Nadim Z. ;
Goodacre, Charles J. .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (03) :470-476
[3]   Incisal coverage or not in ceramic laminate veneers: A systematic review and meta-analysis [J].
Albanesi, Rafael Borges ;
Pigozzo, Monica Nogueira ;
Sesma, Newton ;
Lagana, Dalva Cruz ;
Morimoto, Susana .
JOURNAL OF DENTISTRY, 2016, 52 :1-7
[4]   Long-Term Survival and Complication Rates of Porcelain Laminate Veneers in Clinical Studies: A Systematic Review [J].
Alenezi, Ali ;
Alsweed, Mohammad ;
Alsidrani, Saleh ;
Chrcanovic, Bruno R. .
JOURNAL OF CLINICAL MEDICINE, 2021, 10 (05) :1-14
[5]   Marginal Fit Comparison of CAD/CAM Crowns Milled from Two Different Materials [J].
Azarbal, Atousa ;
Azarbal, Mohsen ;
Engelmeier, Robert L. ;
Kunkel, Thomas C. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (05) :421-428
[6]   Evaluation of the Marginal Fit of a CAD/CAM Zirconia-Based Ceramic Crown System [J].
Baig, Mirza Rustum ;
Al-Tarakemah, Yacoub ;
Abu Kasim, Noor Hayaty ;
Omar, Ridwaan .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (03) :319-329
[7]   Effect of operators' experience and cement space on the marginal fit of an in-office digitally produced monolithic ceramic crown system [J].
Baig, Mirza Rustum ;
Gonzalez, Maria Angela G. ;
Abu Kasim, Noor Hayaty ;
Abu Kassim, Noor Lide ;
Farook, Mohideen Salihu .
QUINTESSENCE INTERNATIONAL, 2016, 47 (03) :181-191
[8]   EVALUATION OF THE MARGINAL FIT OF A ZIRCONIA CERAMIC COMPUTER-AIDED MACHINED (CAM) CROWN SYSTEM [J].
Baig, Mirza Rustum ;
Tan, Keson Beng-Choon ;
Nicholls, Jack I. .
JOURNAL OF PROSTHETIC DENTISTRY, 2010, 104 (04) :216-227
[9]  
Beier US, 2012, INT J PROSTHODONT, V25, P79
[10]   Clinical fit of Procera AllCeram crowns [J].
Boening, KW ;
Wolf, BH ;
Schmidt, AE ;
Kästner, K ;
Walter, MH .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (04) :419-424