摘要
BACKGROUND AND OBJECTIVE: After paired arcuate keratotomies and compression sutures (AK) for treatment of high postkeratoplasty astigmatism, corneal topography tends to be irregular The purpose of this study was to demonstrate a mathematical method for approximation of discrete corneal topography power data with an ellipsoid for better appreciation of the clinical outcome after AK. PATIENTS AND METHODS: Thirty-one eyes of 28 consecutive patients who underwent AK for excessive postkeratoplasty astigmatism were studied. Regular keratometry, corneal topography (TMS-I), subjective refraction, and best-corrected visual acuity (VA) were assessed preoperatively and at 1 week and 1 rear postoperatively. A simplex algorithm was applied for fitting an ellipsoidal surface to raw corneal topography power data. A set of parameters (meridional power, axis, and asphericity) were calculated. The cylinder of subjective refraction was correlated with the keratometric readings, the simulated keratometry (SimK) of the topography system, and the respective parameters of the model surface. RESULTS: Keratometric astigmatism and the cylinder of the model surface decreased from 8.1 +/- 3.2 and 7.9 +/- 2.9 D preoperatively to 4.5 +/- 2.1 and 5.3 +/- 2.0 D after I year, respectively The asphericity in both meridional cross sections changed from a prolate ellipse preoperatively to an ablate ellipse at the early postoperative follow-up stage. Regarding the cylinder axis, there was a significant correlation of the model surface with the refractive cylinder at all examinations (P<.05), whereas there was no significant correlation of the SimK axis and the refractive cylinder axis. CONCLUSION: The approximation of corneal topography power data with an ellipsoidal model surface renders reconstruction of clinically relevant corneal topography parameters, including corneal asphericity with a marked data compression. Even in markedly irregular corneal surfaces, such as after AK, the correlation of amount/axis of refractive cylinder with the model surface parameters is more accurate than it is with respective SimK values of corneal topography analysis.
引用
收藏
页码:738 / 748
页数:11
相关论文
共 44 条
[21]   Fourier analysis as a mathematical model for evaluation and presentation of postoperative corneal topographic data after nonmechanical penetrating keratoplasty [J].
Langenbucher, A ;
Seitz, B ;
Kus, MM ;
Steffen, P ;
Naumann, GOH .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1997, 210 (04) :197-206
[22]  
LANGENBUCHER A, IN PRESS KLIN MONATS
[23]   CORNEAL COMPRESSION SUTURES FOR THE REDUCTION OF ASTIGMATISM AFTER PENETRATING KERATOPLASTY [J].
LIMBERG, MB ;
DINGELDEIN, SA ;
GREEN, MT ;
KLYCE, SD ;
INSLER, MS ;
KAUFMAN, HE .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 108 (01) :36-42
[24]  
LINDSTROM RL, 1988, CORNEA, V7, P138
[25]   CORNEAL TOPOGRAPHY OF TRANSVERSE KERATOTOMIES FOR ASTIGMATISM AFTER PENETRATING KERATOPLASTY [J].
MAGUIRE, LJ ;
BOURNE, WM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 107 (04) :323-330
[26]   DETERMINATION OF CORNEAL IMAGE-FORMING PROPERTIES FROM CORNEAL TOPOGRAPHY [J].
MALONEY, RK ;
BOGAN, SJ ;
WARING, GO .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1993, 115 (01) :31-41
[27]  
MANDELL RB, 1971, BRIT J PHYSIOL OPT, V26, P183
[28]  
MCDONNELL PJ, 1991, REFRACT CORNEAL SURG, V5, P424
[29]   THE BOWMAN-LECTURE [J].
NAUMANN, GOH .
EYE, 1995, 9 :395-421
[30]   193 NM EXCIMER-LASER TREPHINATION IN PENETRATING KERATOPLASTY [J].
NAUMANN, GOH ;
SEITZ, B ;
LANG, GK ;
LANGENBUCHER, A ;
KUS, MM .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1993, 203 (04) :252-261