Bragg peak prediction from quantitative proton computed tomography using different path estimates

被引:21
作者
Wang, Dongxu [1 ]
Mackie, T. Rockwell [1 ,2 ]
Tome, Wolfgang A. [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Sch Med & Publ Hlth, Madison, WI 53705 USA
[2] Univ Wisconsin, Dept Human Oncol, Sch Med & Publ Hlth, Madison, WI 53792 USA
关键词
RECONSTRUCTION; RESOLUTION;
D O I
10.1088/0031-9155/56/3/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper characterizes the performance of the straight-line path (SLP) and cubic spline path (CSP) as path estimates used in reconstruction of proton computed tomography (pCT). The GEANT4 Monte Carlo simulation toolkit is employed to simulate the imaging phantom and proton projections. SLP, CSP and the most-probable path (MPP) are constructed based on the entrance and exit information of each proton. The physical deviations of SLP, CSP and MPP from the real path are calculated. Using a conditional proton path probability map, the relative probability of SLP, CSP and MPP are calculated and compared. The depth dose and Bragg peak are predicted on the pCT images reconstructed using SLP, CSP, and MPP and compared with the simulation result. The root-mean-square physical deviations and the cumulative distribution of the physical deviations show that the performance of CSP is comparable to MPP while SLP is slightly inferior. About 90% of the SLP pixels and 99% of the CSP pixels lie in the 99% relative probability envelope of the MPP. Even at an imaging dose of similar to 0.1 mGy the proton Bragg peak for a given incoming energy can be predicted on the pCT image reconstructed using SLP, CSP, or MPP with 1 mm accuracy. This study shows that SLP and CSP, like MPP, are adequate path estimates for pCT reconstruction, and therefore can be chosen as the path estimation method for pCT reconstruction, which can aid the treatment planning and range prediction of proton radiation therapy.
引用
收藏
页码:587 / 599
页数:13
相关论文
共 12 条
[1]  
ANDERSENAHAND K, 1984, ULTRASONIC IMAGING, V6, P81
[2]   An analytical approximation of the Bragg curve for therapeutic proton beams [J].
Bortfeld, T .
MEDICAL PHYSICS, 1997, 24 (12) :2024-2033
[3]   Reconstruction for proton computed tomography by tracing proton trajectories: A Monte Carlo study [J].
Li, TF ;
Liang, ZR ;
Singanallur, JV ;
Satogata, TJ ;
Williams, DC ;
Schulte, RW .
MEDICAL PHYSICS, 2006, 33 (03) :699-706
[4]   THE RELATION BETWEEN X-RAY CT NUMBERS AND CHARGED-PARTICLE STOPPING POWERS AND ITS SIGNIFICANCE FOR RADIOTHERAPY TREATMENT PLANNING [J].
MUSTAFA, AA ;
JACKSON, DF .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (02) :169-176
[5]   The precision of proton range calculations in proton radiotherapy treatment planning: experimental verification of the relation between CT-HU and proton stopping power [J].
Schaffner, B ;
Pedroni, E .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06) :1579-1592
[6]   The calibration of CT Hounsfield units for radiotherapy treatment planning [J].
Schneider, U ;
Pedroni, E ;
Lomax, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (01) :111-124
[7]   MULTIPLE COULOMB SCATTERING AND SPATIAL-RESOLUTION IN PROTON RADIOGRAPHY [J].
SCHNEIDER, U ;
PEDRONI, E .
MEDICAL PHYSICS, 1994, 21 (11) :1657-1663
[8]   Conceptual design of a proton computed tomography system for applications in proton radiation therapy [J].
Schulte, R ;
Bashkirov, V ;
Li, TF ;
Liang, ZR ;
Mueller, K ;
Heimann, J ;
Johnson, LR ;
Keeney, B ;
Sadrozinski, HFW ;
Seiden, A ;
Williams, DC ;
Zhang, L ;
Li, Z ;
Peggs, S ;
Satogata, T ;
Woody, C .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) :866-872
[9]   A maximum likelihood proton path formalism for application in proton computed tomography [J].
Schulte, R. W. ;
Penfold, S. N. ;
Tafas, J. T. ;
Schubert, K. E. .
MEDICAL PHYSICS, 2008, 35 (11) :4849-4856
[10]   Density resolution of proton computed tomography [J].
Schulte, RW ;
Bashkirov, V ;
Klock, MCL ;
Li, TF ;
Wroe, AJ ;
Evseev, I ;
Williams, DC ;
Satogata, T .
MEDICAL PHYSICS, 2005, 32 (04) :1035-1046