Contactless and cuffless monitoring of blood pressure on a chair using e-textile materials

被引:19
作者
Wu, Kin-fai [1 ]
Chan, Chun-hung [1 ]
Zhang, Yuan-ting [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Elect Engn, JCBME, Shatin, Hong Kong, Peoples R China
来源
2006 3RD IEEE/EMBS INTERNATIONAL SUMMER SCHOOL ON MEDICAL DEVICES AND BIOSENSORS | 2006年
关键词
contactless; cuffless; blood pressure; monitoring; e-textile; pulse transit time;
D O I
10.1109/ISSMDBS.2006.360107
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Blood pressure (BP) can be measured cufflessly and noninvasively by using pulse transit time, which is obtained from simultaneously recorded electrocardiogram (ECG) and photoplethysmogram (PPG). To apply this BP monitoring technique in daily life, an office chair was modified into a contactless and cuffless BP-monitoring device using e-textile materials. In this study, twelve normotensive subjects, including 6 males and 6 females, were recruited for testing this BP-monitoring chair. During the experiment, exercise was carried out to obtain a wider range of BP. In total, 62 pairs of systolic BP (SBP) and diastolic BP (DBP) estimations were made. Readings from a clinically approved cuff-based automatic BP monitor was used as reference. The results showed that the estimated SBP and DBP differed from their references by -6.3 +/- 10.5 mmHg and -0.7 +/- 4.9 mmHg respectively. It was found that the SBP estimation errors mainly came from the data obtained immediately after exercise. Further improvement should be made to minimize those errors. However, this concept is potentially useful in self BP monitoring for home healthcare.
引用
收藏
页码:98 / +
页数:2
相关论文
共 8 条
[1]  
Kearney PM, 2005, LANCET, V365, P217, DOI 10.1016/S0140-6736(05)70151-3
[2]   Cuff-less and noninvasive measurements of arterial blood pressure by pulse transit time [J].
Poon, C. C. Y. ;
Zhang, Y. T. .
2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, :5877-5880
[3]   Recoverability trend of blood pressure and pulse transit time after treadmill exercise [J].
Teng, X. F. ;
Poon, C. C. Y. ;
Zhang, Y. T. .
2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, :3510-3513
[4]   The effect of applied sensor contact force on pulse transit time [J].
Teng, X. F. ;
Zhang, Y. T. .
PHYSIOLOGICAL MEASUREMENT, 2006, 27 (08) :675-684
[5]   The effect of contacting force on photoplethysmographic signals [J].
Teng, XF ;
Zhang, YT .
PHYSIOLOGICAL MEASUREMENT, 2004, 25 (05) :1323-1335
[6]   The effects of exercises on the relationship between pulse transit time and arterial blood pressure [J].
Wong, Y. M. ;
Zhang, Y. T. .
2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, :5576-5578
[7]  
WONG YM, 2004, P 2 IEEE EMBS INT SU
[8]   The effect of local mild cold exposure on pulse transit time [J].
Zhang, Xin-Yu ;
Zhang, Yuan-Ting .
PHYSIOLOGICAL MEASUREMENT, 2006, 27 (07) :649-660