Study of Power Transformer Insulation Model. The X-Y Model of Oil Impregnated Pressboard - Water Nanodrops - Insulating Oil Composite

被引:1
作者
Rogalski, Przemyslaw [1 ]
机构
[1] Lublin Univ Technol, Dept Elect Devices & High Voltage Technol, Lublin, Poland
来源
PROCEEDINGS OF THE 2020 IEEE 10TH INTERNATIONAL CONFERENCE ON NANOMATERIALS: APPLICATIONS & PROPERTIES (NAP-2020) | 2020年
关键词
pressboard; transformer insulation; water nanodrops; paper-oil insulation; FDS; X-Y model; ELECTROTECHNICAL PRESSBOARD; CELLULOSE; CONDUCTIVITY; COATINGS;
D O I
10.1109/nap51477.2020.9309687
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The paper presents a measuring stand enabling measurements with the use of the Frequency Domain Spectroscopy method. The process of making a measuring sample consistent with the X-Y model of a power transformer is discussed. The results of measurements of alternating current electrical parameters such as: admittance, phase shift angle, conductivity, permittivity, loss angle tangent, power loss coefficient are presented. Exemplary measurements were made for the temperatures of 293.15 K, 301.15 K, 309.15 K, 317.15 K, 325.15 K and 333.15 K in the frequency range from 0.1 mHz to 5 KHz.
引用
收藏
页数:4
相关论文
共 18 条
[1]  
Kierczy~ski K., 2017, PHOTONICS APPL ASTRO, V1044
[2]   Tests of Impregnation Speed of Electrotechnical Pressboard with Insulating Oil [J].
Kozak, C. .
DEVICES AND METHODS OF MEASUREMENTS, 2020, 11 (02) :140-147
[3]   Preparation, characterization, and corrosion behavior of protective coatings on stainless steel samples deposited by plasma detonation techniques [J].
Misaelides, P ;
Hatzidimitriou, A ;
Noli, F ;
Pogrebnjak, AD ;
Tyurin, YN ;
Kosionidis, S .
SURFACE & COATINGS TECHNOLOGY, 2004, 180 :290-296
[4]   Measuring Setup for Investigation and Visualization of the Percolation Phenomenon in Non-Ordered Models of Metal-Dielectric Nanocomposites [J].
Okal, P. .
DEVICES AND METHODS OF MEASUREMENTS, 2020, 11 (03) :171-178
[5]   Microstructure, physical and chemical properties of nanostructured (Ti-Hf-Zr-V-Nb)N coatings under different deposition conditions [J].
Pogrebnjak, A. D. ;
Yakushchenko, I. V. ;
Bagdasaryan, A. A. ;
Bondar, O. V. ;
Krause-Rehberg, R. ;
Abadias, G. ;
Chartier, P. ;
Oyoshi, K. ;
Takeda, Y. ;
Beresnev, V. M. ;
Sobol, O. V. .
MATERIALS CHEMISTRY AND PHYSICS, 2014, 147 (03) :1079-1091
[6]   Cellulose insulation in oil-filled power transformers: Part I - History and development [J].
Prevost, TA ;
Oommen, TV .
IEEE ELECTRICAL INSULATION MAGAZINE, 2006, 22 (01) :28-35
[7]   Measurement Stand, Method and Results of Composite Electrotechnical Pressboard-Mineral Oil Electrical Measurements [J].
Rogalski, P. .
DEVICES AND METHODS OF MEASUREMENTS, 2020, 11 (03) :187-195
[8]   Review of time-domain polarization measurements for assessing insulation condition in aged transformers [J].
Saha, TK .
IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (04) :1293-1301
[9]   Advances in the development of detonation technologies and equipment for coating deposition [J].
Tyurin, YN ;
Pogrebnjak, AD .
SURFACE & COATINGS TECHNOLOGY, 1999, 111 (2-3) :269-275
[10]   Improved method for measuring moisture content of mineral-oil-impregnated cellulose pressboard based on dielectric response [J].
Zhang, M. ;
Liu, J. ;
Lv, J. ;
Chen, Q. ;
Qi, P. ;
Sun, Y. ;
Jia, H. ;
Chen, X. .
CELLULOSE, 2018, 25 (10) :5611-5622