Improvement of precision in quantitative measurements of radioactivity with an imaging plate

被引:5
作者
Suzuki, T
Mori, C
Miyahara, H
Uritani, A
Yoshida, M
Takahashi, F
机构
[1] Nagoya Univ, Dept Nucl Engn, Chikusa Ku, Nagoya, Aichi 46401, Japan
[2] Japan Atom Energy Res Inst, Tokai Estab, Dept Hlth Phys, Tokai, Ibaraki 31911, Japan
关键词
D O I
10.1016/S0969-8043(97)10032-X
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
To obtain a high precision in radiation or radioactivity measurements with an imaging plate, the photo-stimulated luminescence intensity must be large. To get the highest intensity, we reread an imaging plate repeatedly and summed each intensity for the purpose of reducing the variation of the measured intensities. A great improvement of the precision in the measurement was achieved with the method of repeated readings when the time interval between each reading is more than about 1 h. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1127 / 1130
页数:4
相关论文
共 11 条
[1]   DESIGN AND PERFORMANCE OF AN IMAGING PLATE SYSTEM FOR X-RAY-DIFFRACTION STUDY [J].
AMEMIYA, Y ;
MATSUSHITA, T ;
NAKAGAWA, A ;
SATOW, Y ;
MIYAHARA, J ;
CHIKAWA, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3) :645-653
[2]   X-RAY-ENERGY DEPENDENCE AND UNIFORMITY OF AN IMAGING PLATE DETECTOR [J].
ITO, M ;
AMEMIYA, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2) :369-372
[3]   LASER-BEAM PROFILER IN THE VACUUM ULTRAVIOLET SPECTRAL RANGE USING PHOTOSTIMULABLE PHOSPHOR [J].
KATTO, M ;
MATSUMOTO, R ;
KUROSAWA, K ;
SASAKI, W ;
TAKIGAWA, Y ;
OKUDA, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (02) :319-324
[4]   Radioactivity distribution measurement of various natural material surfaces with imaging plate [J].
Mori, C ;
Suzuki, T ;
Koido, S ;
Uritani, A ;
Miyahara, H ;
Yanagida, K ;
Wu, Y ;
Nishizawa, K ;
Yoshida, M ;
Takahashi, F ;
Miyahara, J .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1996, 206 (02) :263-267
[5]   MEASUREMENT OF THE RADIOACTIVITY DISTRIBUTION OF MATERIAL-SURFACES WITH AN IMAGING PLATE [J].
MORI, C ;
SUZUKI, T ;
KOIDO, S ;
MIYAHARA, H ;
URITANI, A ;
AOYAMA, T ;
NISHIZAWA, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :371-374
[6]   DETECTION OF EXTREMELY LOW-LEVEL RADIOACTIVITY WITH IMAGING PLATE [J].
MORI, C ;
MATSUMURA, A ;
SUZUKI, T ;
MIYAHARA, H ;
AOYAMA, T ;
NISHIZAWA, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (1-2) :278-281
[7]   AN IMAGINING PLATE NEUTRON DETECTOR [J].
NIIMURA, N ;
KARASAWA, Y ;
TANAKA, I ;
MIYAHARA, J ;
TAKAHASHI, K ;
SAITO, H ;
KOIZUMI, S ;
HIDAKA, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 349 (2-3) :521-525
[8]  
OIKAWA T, 1994, J ELECTRON MICROSC, V43, P402
[9]   Characteristics and correction of the fading of imaging plate [J].
Suzuki, T ;
Mori, C ;
Yanagida, K ;
Uritani, A ;
Miyahara, H .
JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1997, 34 (05) :461-465
[10]  
SUZUKI T, 1997, IN PRESS NUCL INSTRU