Comparison of Thresholds for Pulmonary Capillary Hemorrhage Induced by Pulsed-wave and B-mode Ultrasound

被引:2
作者
Miller, Douglas L. [1 ]
Dou, Chunyan [1 ]
Raghavendran, Krishnan [2 ]
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Surg, Ann Arbor, MI 48109 USA
来源
Proceedings of the 2015 ICU International Congress on Ultrasonics | 2015年 / 70卷
关键词
Pulmonary ultrasound; comet tail artifact; bioeffects of ultrasound; ultrasound dosimetry; Mechanical Index; INDUCED LUNG HEMORRHAGE; SUPERTHRESHOLD BEHAVIOR; DIAGNOSTIC ULTRASOUND; RATS; EXPOSURE;
D O I
10.1016/j.phpro.2015.08.232
中图分类号
O59 [应用物理学];
学科分类号
摘要
Pulsed ultrasound was found to induce pulmonary capillary hemorrhage (PCH) in mice about 25 years ago but remains a poorly understood risk factor for pulmonary diagnostic ultrasound. In early research using laboratory fixed beam ultrasound, thresholds for PCH had frequency variation from 1-4 MHz similar to the Mechanical Index. In recent research, thresholds for B mode diagnostic ultrasound from 1.5-12 MHz had little dependence on frequency. To compare the diagnostic ultrasound method to laboratory pulsed exposure, thresholds for fixed beam ultrasound were determined using comparable methods at 1.5 and 7.5 MHz. PCH thresholds were lower for simple fixed-beam pulse modes than for B mode and in approximate agreement with early research. However, for comparable timing parameters, PCH thresholds had little dependence on ultrasonic frequency. These findings suggest that the MI may not be directly useful as a dosimetric parameter for safety guidance in pulmonary ultrasound. (C) 2015 The Authors. Published by Elsevier B.V.
引用
收藏
页码:1087 / 1090
页数:4
相关论文
共 8 条
[1]  
American Institute of Ultrasound in Medicine, 2000, J ULTRAS MED, V19, P97
[2]  
[Anonymous], 2000, J. ultrasound Med, V19, P154
[3]   LUNG DAMAGE FROM EXPOSURE TO PULSED ULTRASOUND [J].
CHILD, SZ ;
HARTMAN, CL ;
SCHERY, LA ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (08) :817-825
[4]   The risk of exposure to diagnostic ultrasound in postnatal subjects - Nonthermal mechanisms [J].
Church, Charles C. ;
Carstensen, Edwin L. ;
Nyborg, Wesley L. ;
Carson, Paul L. ;
Frizzell, Leon A. ;
Bailey, Michael R. .
JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (04) :565-592
[5]  
Miller D. L., 2015, ULTRASOUND IN PRESS, V41
[6]   INDUCTION OF PULMONARY HEMORRHAGE IN RATS DURING DIAGNOSTIC ULTRASOUND [J].
Miller, Douglas L. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (08) :1476-1482
[7]   Threshold estimates and superthreshold behavior of ultrasound-induced lung hemorrhage in adult rats: Role of pulse duration [J].
O'Brien, WD ;
Simpson, DG ;
Frizzell, LA ;
Zachary, JF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (11) :1625-1634
[8]   Superthreshold behavior and threshold estimation of ultrasound-induced lung hemorrhage in adult mice and rats [J].
Zachary, JF ;
Sempsrott, JM ;
Frizzell, LA ;
Simpson, DG ;
O'Brien, WD .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (02) :581-592