Random coincidences during in-beam PET measurements at microbunched therapeutic ion beams

被引:41
|
作者
Parodi, K
Crespo, P
Eickhoff, H
Haberer, T
Pawelke, J
Schardt, D
Enghardt, W
机构
[1] Forschungszentrum Rossendorf EV, Inst Nucl & Hadron Phys, D-01314 Dresden, Germany
[2] Gesell Schwerionenforsch mbH, D-64291 Darmstadt, Germany
关键词
positron emission tomography; random correction; carbon ion therapy;
D O I
10.1016/j.nima.2005.02.002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
At the experimental carbon ion tumour therapy facility at GSI Darmstadt, in-beam positron emission tomography (PET) is used to monitor the dose delivery precision. A dual head positron camera has been assembled from Commercial detector components in order to measure the beta(+)-activity. induced by (fie irradiation, simultaneously it) the dose application. Despite the positive clinical impact, the image quality is limited by the low counting statistics, orders of magnitude below that in standard PET applications to nuclear medicine, This paper investigates the origin for the noisy acquisition during particle extraction from the synchrotron or GSI. The results demonstrate the failure of standard random correction techniques due to gamma-ray background correlated in time with the carbon ion beam microstructure, This prevents the use of data acquired during beam extraction for imaging, The loss Of Counting Statistics is expected to rise further at the future hospital-based facility at Heidelberg, due to a more efficient utilisation of file accelerator resulting in shorter beam pauses and a reduced treatment time. In this respect, this paper provides the basis for it new data acquisition concept tailored to the unconventional application of in-beam PET imaging to therapy monitoring at radiofrequency pulsed radiation sources. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:446 / 458
页数:13
相关论文
共 13 条
  • [1] In-Beam and Off-Beam PET Measurements of Target Activation by Megavolt X-Ray Beams
    Kunath, Daniela
    Kluge, Thomas
    Pawelke, Joerg
    Priegnitz, Marlen
    Enghardt, Wolfgang
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (01) : 57 - 65
  • [2] In-beam PET at clinical proton beams with pile-up rejection
    Helmbrecht, Stephan
    Enghardt, Wolfgang
    Fiedler, Fine
    Lltzsche, Marc
    Pausch, Guntram
    Tintori, Carlo
    Kormoll, Thomas
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (03): : 202 - 217
  • [3] Range verification of radioactive ion beams of 11C and 15O using in-beam PET imaging
    Mohammadi, Akram
    Tashima, Hideaki
    Iwao, Yuma
    Takyu, Sodai
    Akamatsu, Go
    Nishikido, Furnihiko
    Yoshida, Eiji
    Kitagawa, Atsushi
    Parodi, Katia
    Yamaya, Taiga
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (14)
  • [4] Performance of a fast acquisition system for in-beam PET monitoring tested with clinical proton beams
    Piliero, M. A.
    Bisogni, M. G.
    Cerello, P.
    Del Guerra, A.
    Fiorina, E.
    Liu, B.
    Morrocchi, M.
    Pennazio, F.
    Pirrone, G.
    Wheadon, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 804 : 163 - 166
  • [5] First 4D In-beam PET Measurement for Beam Tracking of a Moving Phantom with a Scanned Carbon Ion Beam
    Parodi, K.
    Saito, N.
    Richter, C.
    Chaudhri, N.
    Enghardt, W.
    Rietzel, E.
    Bert, C.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3794 - +
  • [6] An in-beam PET system for monitoring ion-beam therapy: test on phantoms using clinical 62 MeV protons
    Camarlinghi, N.
    Sportelli, G.
    Battistoni, G.
    Belcari, N.
    Cecchetti, M.
    Cirrone, G. A. P.
    Cuttone, G.
    Ferretti, S.
    Kraan, A.
    Retico, A.
    Romano, F.
    Sala, P.
    Straub, K.
    Tramontana, A.
    Del Guerra, A.
    Rosso, V.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [7] Full-beam performances of a PET detector with synchrotron therapeutic proton beams
    Piliero, M. A.
    Pennazio, F.
    Bisogni, M. G.
    Camarlinghi, N.
    Cerello, P. G.
    Del Guerra, A.
    Ferrero, V.
    Fiorina, E.
    Giraudo, G.
    Morrocchi, M.
    Peroni, C.
    Pirrone, G.
    Sportelli, G.
    Wheadon, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (23) : N650 - N666
  • [8] Quantitative assessment of radionuclide production yields in in-beam and offline PET measurements at different proton irradiation facilities
    Bauer, Julia
    Hildebrandt, Meret
    Baumgartl, Michael
    Fiedler, Fine
    Robert, Charlotte
    Buvat, Irene
    Enghardt, Wolfgang
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (15)
  • [9] Experimental verification of a 4D MLEM reconstruction algorithm used for in-beam PET measurements in particle therapy
    Stuetzer, K.
    Bert, C.
    Enghardt, W.
    Helmbrecht, S.
    Parodi, K.
    Priegnitz, M.
    Saito, N.
    Fiedler, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (15) : 5085 - 5111
  • [10] Comparison between in-beam and offline positron emission tomography imaging of proton and carbon ion therapeutic irradiation at synchrotron- and cyclotron-based facilities
    Parodi, Katia
    Bortfeld, Thomas
    Haberer, Thomas
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (03): : 945 - 956