Effect of femoral to tibial varus mismatch on the contact area of unicondylar knee prostheses

被引:24
作者
Diezi, Christian [1 ]
Wirth, Stephan [1 ]
Meyer, Dominik C. [1 ]
Koch, Peter P. [1 ]
机构
[1] Univ Zurich, Dept Orthopaed, Zurich, Switzerland
关键词
Unicondylar knee; Contact area; Geometry; Loosening; Position; WEAR; ARTHROPLASTY; POLYETHYLENE; REPLACEMENT; PRESSURE; BEARING;
D O I
10.1016/j.knee.2009.10.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In unicondylar knee prostheses, the relative angle and congruency of the femoral against the tibial component is not mechanically constrained and may vary with the surgical implantation technique The contact area between both components was measured with increasing vat us (0-20 degrees) and flexion angles (-20 degrees to 90) in five prosthesis models in the laboratory The contact area varied with the relative position of the components and was critically reduced up to 70% at a yams range between >5 degrees and <25 degrees The importance of relative malpositioning of the femoral and tibial components may be underestimated and reduces the contact area of unicondylar piostheses decisively, independent from the limb axis This increases local pressure and may thus importantly contribute to increased wear and early loosening (c) 2009 Elsevier B.V All rights reserved
引用
收藏
页码:350 / 355
页数:6
相关论文
共 17 条
[1]   Polyethylene wear in a non-congruous unicompartmental knee replacement: a retrieval analysis [J].
Ashraf, T ;
Newman, JH ;
Desai, VV ;
Beard, D ;
Nevelos, JE .
KNEE, 2004, 11 (03) :177-181
[2]   Measuring contact area, force, and pressure for bioengineering applications: Using Fuji Film and TekScan systems [J].
Bachus, Kent N. ;
DeMarco, Alyssa L. ;
Judd, Kyle T. ;
Horwitz, Daniel S. ;
Brodke, Darrel S. .
MEDICAL ENGINEERING & PHYSICS, 2006, 28 (05) :483-488
[3]   The influence of the presence and severity of pre-existing patellofemoral degenerative changes on the outcome of the Oxford medial unicompartmental knee replacement [J].
Beard, D. J. ;
Pandit, H. ;
Gill, H. S. ;
Hollinghurst, D. ;
Dodd, C. A. F. ;
Murray, D. W. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (12) :1597-1601
[4]   Wear in retrieved condylar knee arthroplasties - A comparison of wear in different designs of 280 retrieved condylar knee prostheses [J].
Blunn, GW ;
Joshi, AB ;
Minns, RJ ;
Lidgren, L ;
Lilley, P ;
Ryd, L ;
Engelbrecht, E ;
Walker, PS .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :281-290
[5]  
CABRAL CWL, 2006, J ORAL SCI, V19, P1239
[6]   The influence of surgical malalignment on the contact pressures of fixed and mobile bearing knee prostheses - a biomechanical study [J].
Cheng, CK ;
Huang, CH ;
Liau, JJ ;
Huang, CH .
CLINICAL BIOMECHANICS, 2003, 18 (03) :231-236
[7]   Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty [J].
Collier, Matthew B. ;
Engh, C. Anderson, Jr. ;
McAuley, James P. ;
Engh, Gerard A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (06) :1306-1314
[8]   Patient, implant, and alignment factors associated with revision of medial compartment unicondylar arthroplasty [J].
Collier, Matthew B. ;
Eickmann, Thomas H. ;
Sukezaki, Fumio ;
McAuley, James P. ;
Engh, Gerard A. .
JOURNAL OF ARTHROPLASTY, 2006, 21 (06) :108-115
[9]   Survival of medial unicondylar arthroplasties placed by one surgeon 1984-1998 [J].
Eickmann, Thomas H. ;
Collier, Matthew B. ;
Sukezaki, Fumio ;
McAuley, James P. ;
Engh, Gerard A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) :143-149
[10]   An improved method for measuring tibiofemoral contact areas in total knee arthroplasty: a comparison of K-scan sensor and Fuji film [J].
Harris, ML ;
Morberg, P ;
Bruce, WJM ;
Walsh, WR .
JOURNAL OF BIOMECHANICS, 1999, 32 (09) :951-958