摘要
Background Diseases of the bowel are not always displayed on conventional abdominal computed tomography (CT). The studied oral contrast agent aims to improve this. Purpose To investigate whether the use of a novel oral contrast for abdominal CT enables the same diagnostic advantages as seen in magnetic resonance imaging (MRI). Material and Methods Twenty-five consented volunteers drank up to 1400 mL of a stable, drinkable foam. Comments on acceptance and side effects were noted immediately and 24 h later. Foam palatability was documented through interviews, and distribution in the small bowel by Hounsfield units from the CT software. The CT results were compared with age- and sex-matched controls, pretreated according to routine. A non-enhanced abdominal CT protocol of lowest possible radiation dose was used. External referees evaluated all data obtained. Results Foam was considered odd to swallow, and fullness was reported by all volunteers after 950 mL. Five had difficulties in drinking the last 320 mL and two abstained from it. All adverse symptoms were mild. The distribution in the small bowel was on par with standard agents. Foam density revealed stability with intraluminal values of around -550 HU from stomach to terminal ileum, satisfying the requirement of a great bowel lumen-to-wall contrast. External reviewers re-evaluated all our data, and one predicted the foam to offer a potential for improved diagnostics. Conclusion A CT true-negative bowel filling agent was formulated, with high acceptance, few side effects, and a potential to mimic T1-weighted MRI images.
引用
收藏
页码:1559 / 1566
页数:8
相关论文
共 27 条
[1]  
Allen IE., 2007, QUAL PROG, V40, P64, DOI DOI 10.1111/J.1365-2929.2004.02012.X
[2]   Effectiveness of MR Enterography for the Assessment of Small-Bowel Diseases beyond Crohn Disease [J].
Amzallag-Bellenger, Elisa ;
Oudjit, Ammar ;
Ruiz, Ana ;
Cadiot, Guillaume ;
Soyer, Philippe A. ;
Hoeffel, Christine C. .
RADIOGRAPHICS, 2012, 32 (05) :1423-1444
[3]   Inflammatory bowel disease—the role of cross-sectional imaging techniques in the investigation of the small bowel [J].
Athanasakos A. ;
Mazioti A. ;
Economopoulos N. ;
Kontopoulou C. ;
Stathis G. ;
Filippiadis D. ;
Spyridopoulos T. ;
Alexopoulou E. .
Insights into Imaging, 2015, 6 (1) :73-83
[4]   CT enterography for Crohn's disease: optimal technique and imaging issues [J].
Baker, Mark E. ;
Hara, Amy K. ;
Platt, Joel F. ;
Maglinte, Dean D. T. ;
Fletcher, Joel G. .
ABDOMINAL IMAGING, 2015, 40 (05) :938-952
[5]   COMPUTED TOMOGRAPHY OF PANCREAS - NEGATIVE CONTRAST-MEDIUM [J].
BALDWIN, GN .
RADIOLOGY, 1978, 128 (03) :827-828
[6]   Comparison of neutral oral contrast versus positive oral contrast medium in abdominal multidetector CT [J].
Berther, Ralph ;
Patak, Michael A. ;
Eckhardt, Boris ;
Erturk, Sukru M. ;
Zollikofer, Christoph L. .
EUROPEAN RADIOLOGY, 2008, 18 (09) :1902-1909
[7]   Utility of MR Enterography and Ultrasound for the Investigation of Small Bowel Crohn's Disease [J].
Bhatnagar, Gauraang ;
Von Stempel, Conrad ;
Halligan, Steve ;
Taylor, Stuart A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (06) :1573-1588
[8]  
Clason D.L., 1994, Journal of Agricultural Education, V35, P4, DOI [10.5032/jae.1994.04031, DOI 10.5032/JAE.1994.04031]
[9]   Neuroendocrine tumors of the small bowel: evaluation with MR-enterography [J].
Dohan, Anthony ;
El Fattach, Hassan ;
Barat, Maxime ;
Guerrache, Youcef ;
Eveno, Clarisse ;
Dautry, Raphael ;
Mule, Sebastien ;
Boudiaf, Mourad ;
Hoeffel, Christine ;
Soyer, Philippe .
CLINICAL IMAGING, 2016, 40 (03) :541-547
[10]   Improvement of distension and mural visualization of bowel loops using neutral oral contrasts in abdominal computed tomography [J].
Hashemi, Jahanbakhsh ;
Davoudi, Yasmin ;
Taghavi, Mina ;
Rad, Masoud Pezeshki ;
Moghadam, Amien Mahajeri .
WORLD JOURNAL OF RADIOLOGY, 2014, 6 (12) :907-912