Three-dimensional quantitation of mitral valve coaptation by a novel software system with transthoracic real-time three-dimensional echocardiography

被引:32
作者
Tsukiji, Miwako [1 ]
Watanabe, Nozomi
Yamaura, Yasuko
Okahashi, Noriko
Obase, Kikuko
Neishi, Yoji
Toyota, Eiji
Kawamoto, Takahiro
Okura, Hiroyuki
Ogasawara, Yasuo
Yoshida, Kiyoshi
机构
[1] Kawasaki Med Sch, Dept Cardiol, Kurashiki, Okayama 7010192, Japan
关键词
D O I
10.1016/j.echo.2007.05.023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We investigated the degree of mitral valve coaptation with a custom quantitation software system using transthoracic three-dimensional (3D) echocardiography. With real-time 3D echocardiography, we obtained transthoracic volumetric images in 20 healthy subjects and 20 patients with dilated cardiomyopathy. With our novel software system, the surface area of mitral valve tenting in the onset of mitral leaflet closure [0] and the timing of maximum closure of mitral leaflet [M] were reconstructed for quantitative measurement. The coaptation index was calculated by the following formula: [(3D tenting surface area in O-3D tenting surface area in M)/3D tenting surface area in O]. The coaptation index in patients with dilated cardiomyopathy was significantly smaller than that in healthy subjects (11% +/- 4.1% vs. 18% +/- 8.0%, P = .004). The custom quantitation software system with 3D echocardiography allowed us to assess the degree of mitral valve coaptation.
引用
收藏
页码:43 / 46
页数:4
相关论文
共 50 条
[31]   Three-dimensional echocardiography and mitral valve disease [J].
Chapman C.B. ;
Rahko P.S. .
Current Cardiology Reports, 2010, 12 (3) :243-249
[32]   Three-dimensional Echocardiography in Mitral Valve Disease [J].
Kamp, Otto ;
Valocik, Gabriel .
EUROPEAN CARDIOLOGY REVIEW, 2005,
[33]   Real-time three-dimensional echocardiography: An overview [J].
Panza, JA .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2001, 17 (03) :227-235
[34]   Real-time three-dimensional fetal echocardiography [J].
Nelson, T. ;
Sklansky, M. ;
Strachan, M. ;
Pretorius, D. .
Ultrasound in Medicine and Biology, 2000, 26 (SUPPL. 2)
[35]   3D quantitation of mitral valve coaptation by novel software system with transthoracic real-time 3D echocardiography [J].
Tsukiji, Miwako ;
Watanabe, Nozomi ;
Yamaura, Yasuko ;
Okahashi, Noriko ;
Okura, Hiroyuki ;
Ogasawara, Yasuo ;
Yoshida, Kiyoshi .
CIRCULATION, 2006, 114 (18) :716-717
[36]   Real-time three-dimensional intracardiac echocardiography [J].
Light, ED ;
Idriss, SF ;
Wolf, PD ;
Smith, SW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (09) :1177-1183
[37]   Real-time three-dimensional echocardiography: An update [J].
Correale, Michele ;
Ieva, Riccardo ;
Di Biase, Matteo .
EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2008, 19 (04) :241-248
[38]   Real-time three-dimensional echocardiography: An overview [J].
Julio A. Panza .
The International Journal of Cardiovascular Imaging, 2001, 17 :227-235
[39]   Evaluation of the morphology and function of the tricuspid valve with three-dimensional transthoracic echocardiography in real time [J].
Esposito, Roberta ;
Badano, Luigi P. ;
Muraru, Denisa ;
Agricola, Eustachio ;
Mele, Donato ;
Sciomer, Susanna ;
Nistri, Stefano ;
Galderisi, Maurizio ;
Mondillo, Sergio .
GIORNALE ITALIANO DI CARDIOLOGIA, 2010, 11 (07) :549-556
[40]   Cor triatriatum sinistrum: a real-time three-dimensional transthoracic echocardiography evaluation [J].
Sirugo, L. ;
Licciardi, S. ;
Monte, I. .
MINERVA CARDIOANGIOLOGICA, 2011, 59 (01) :116-118