Analytical setup margin for spinal stereotactic body radiotherapy based on measured errors

被引:4
作者
Copeland, Audrey [1 ,2 ]
Barron, Addie [1 ,2 ]
Fontenot, Jonas [1 ,2 ,3 ]
机构
[1] Louisiana State Univ, Dept Phys & Astron, Baton Rouge, LA 70803 USA
[2] Agr & Mech Coll, Baton Rouge, LA 70807 USA
[3] Mary Bird Perkins Canc Ctr, Dept Phys, Baton Rouge, LA USA
关键词
Spine; SBRT; Stereotactic; PTV; Margin; RADIOSURGERY; MOTION;
D O I
10.1186/s13014-021-01956-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background No consensus currently exists about the correct margin size to use for spinal SBRT. Margins have been proposed to account for various errors individually, but not with all errors combined to result in a single margin value. The purpose of this work was to determine a setup margin for five-fraction spinal SBRT based on known errors during radiotherapy to achieve at least 90% coverage of the clinical target volume with the prescription dose for at least 90% of patients and not exceed a 30 Gy point dose or 23 Gy to 10% of the spinal cord subvolume. Methods The random and systematic error components of intrafraction motion, residual setup error, and end-to-end system accuracy were measured. The patient's surface displacement was measured to quantify intrafraction motion, the residual setup error was quantified by re-registering accepted daily cone beam computed tomography setup images, and the displacement between measured and planned dose profiles in a phantom quantified the end-to-end system accuracy. These errors and parameters were used to identify the minimum acceptable margin size. The margin recommendation was validated by assessing dose delivery across 140 simulated patient plans suffering from various random shifts representative of the measured errors. Results The errors were quantified in three dimensions and the analytical margin generated was 2.4 mm. With this margin applied in the superior/inferior direction only, at least 90% of the CTV was covered with the prescription dose for 96% of the 140 patients simulated with minimal negative effect on the spinal cord dose levels. Conclusions The findings of this work support that a 2.4 mm margin applied in the superior/inferior direction can achieve at least 90% coverage of the CTV for at least 90% of dual-arc volumetric modulated arc therapy spinal SBRT patients in the presence of errors when immobilized with vacuum bags.
引用
收藏
页数:8
相关论文
共 18 条
  • [11] Time dependence of intrafraction patient motion assessed by repeat stereoscopic imaging
    Hoogeman, Mischa S.
    Nuyttens, Joost J.
    Levendag, Peter C.
    Heumen, Ben J. M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (02): : 609 - 618
  • [12] A novel CBCT-based method for derivation of CTV-PTV margins for prostate and pelvic lymph nodes treated with stereotactic ablative radiotherapy
    Lyons, Ciara A.
    King, Raymond B.
    Osman, Sarah O. S.
    McMahon, Stephen J.
    O'Sullivan, Joe M.
    Hounsell, Alan R.
    Jain, Suneil
    McGarry, Conor K.
    [J]. RADIATION ONCOLOGY, 2017, 12
  • [13] PTV margin definition in hypofractionated IGRT of localized prostate cancer using cone beam CT and orthogonal image pairs with fiducial markers
    Oehler, Christoph
    Lang, Stephanie
    Dimmerling, Peter
    Bolesch, Christian
    Kloeck, Stephan
    Tini, Alessandra
    Glanzmann, Christoph
    Najafi, Yousef
    Studer, Gabriela
    Zwahlen, Daniel R.
    [J]. RADIATION ONCOLOGY, 2014, 9 : 229
  • [14] Parker Brent C, 2002, J Appl Clin Med Phys, V3, P176, DOI 10.1120/1.1474308
  • [15] The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy
    van Herk, M
    Remeijer, P
    Rasch, C
    Lebesque, JV
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (04): : 1121 - 1135
  • [16] Errors and margins in radiotherapy
    van Herk, M
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) : 52 - 64
  • [17] Dosimetric effect of translational and rotational errors for patients undergoing image-guided stereotactic body radiotherapy for spinal metastases
    Wang, He
    Shiu, Almon
    Wang, Congjun
    O'Daniel, Jennifer
    Mahajan, Anita
    Woo, Shiao
    Liengsawangwong, Praimakorn
    Mohan, Radhe
    Chang, Eric L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (04): : 1261 - 1271
  • [18] Setup uncertainties in linear accelerator based stereotactic radiosurgery and a derivation of the corresponding setup margin for treatment planning
    Zhang, Mutian
    Zhang, Qinghui
    Gan, Hua
    Li, Sicong
    Zhou, Su-min
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 379 - 385