Investigation on influential factors of engineering design of geothermal heat exchangers

被引:38
作者
Zhang, Wenke [1 ]
Yang, Hongxing [1 ]
Lu, Lin [1 ]
Fang, Zhaohong [2 ]
机构
[1] Hong Kong Polytech Univ, Renewable Energy Res Grp, Hong Kong, Hong Kong, Peoples R China
[2] Shandong Zhongrui New Energy Technol Co Ltd, Jinan, Peoples R China
关键词
Borehole; Ground heat exchangers; Ground-coupled heat pump; Heat transfer; U-tube; Influential factors; PUMP SYSTEM;
D O I
10.1016/j.applthermaleng.2015.03.023
中图分类号
O414.1 [热力学];
学科分类号
摘要
The research on heat transfer models of geothermal ground heat exchangers (GHEs) of ground-coupled heat pump (GCHP) system has recently advanced greatly. However, although it is important to optimize the design size of GHEs for reducing the total length of GHEs, the optimization of GHEs by means of models is a little. This paper describes the interior simulation models of borehole in which single U-tube and double U-tubes are each buried. The analytical solutions concerning the borehole's exterior heat transfer are given. All the factors that exert influences on the design size of GHEs are described based on the results of the heat transfer models. These significant parameters consist of the centre to centre distance of the U-tube, thermal conductivity of the backfill material, distance of adjacent boreholes, types of circulating liquid or underground medium, arrangement of boreholes, and the minimum temperature of the circulating liquid which enters the heat pump. Using the simulation models and computer programming, the influence degrees of the above factors are discussed in terms of the adoption of different values or types. Therefore, the initial cost and the economic performance of the system are respectively dropped and improved. The investigation on optimization of GHEs is favourable for the further development of GCHP technology. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:310 / 319
页数:10
相关论文
共 27 条
  • [11] HELLSTROM G, 1991, THESIS U LUND SWEDEN
  • [12] Calculation algorithm of the temperatures for pipe arrangement of multiple ground heat exchangers
    Katsura, Takao
    Nagano, Katsunori
    Narita, Shigeaki
    Takeda, Sayaka
    Nakamura, Yasushi
    Okamoto, Atsushi
    [J]. APPLIED THERMAL ENGINEERING, 2009, 29 (5-6) : 906 - 919
  • [13] KAVANAUGH SP, 1992, ASHRAE TRAN, V98, P607
  • [14] Kavanaugh Stephen P., 2000, ASHRAE T S, P446
  • [15] Ping Cui, 2010, BUILD ENERGY ENV, V29, P50
  • [16] Simulation study on the thermal performance of vertical U-tube heat exchangers for ground source heat pump system
    Pu, Liang
    Qi, Di
    Li, Kang
    Tan, Hongbo
    Li, Yanzhong
    [J]. APPLIED THERMAL ENGINEERING, 2015, 79 : 202 - 213
  • [17] New methodology to design ground coupled heat pump systems based on total cost minimization
    Robert, Felix
    Gosselin, Louis
    [J]. APPLIED THERMAL ENGINEERING, 2014, 62 (02) : 481 - 491
  • [18] Spitler J.D., 2010, J SHANDONG JIANZHU U, V25, P95
  • [19] Wang Maosheng, 2010, THESIS SHANDONG JAIN
  • [20] Wei Yu, 2008, J HV AC, V38, P73