ZVS frequency analysis of a current-fed resonant converter

被引:18
作者
Hu, AP [1 ]
Boys, JT [1 ]
Covic, GA [1 ]
机构
[1] Univ Auckland, Elect & Elect Dept, Auckland 1, New Zealand
来源
VII IEEE INTERNATIONAL POWER ELECTRONICS CONGRESS, TECHNICAL PROCEEDINGS: CIEP 2000 | 2000年
关键词
D O I
10.1109/CIEP.2000.891417
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
ZVS (Zero Voltage Switching) is a basic control strategy for normal current-fed DC-AC parallel resonant converters. However, the ZVS operating frequency and how it varies with the load and system parameters remains an unsolved theoretical problem of practical Importance. After identifying different types of resonant frequencies of a typical resonant tank of a current-fed resonant converter, this paper gives both accurate numerical solution and approximate analytical solution of ZVS frequencies. The analysis is based on a step current infection model in a half-switching cycle. The validity of the analysis Is proven with PSpice simulation results.
引用
收藏
页码:217 / 221
页数:5
相关论文
共 6 条
[1]   Stability and control of inductively coupled power transfer systems [J].
Boys, JT ;
Covic, GA ;
Green, AW .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2000, 147 (01) :37-43
[2]  
BOYS JT, 1995, IPENZ T, V22, P1
[3]   MODELING A PUSH PUSH PARALLEL RESONANT CONVERTER USING GENERALIZED STATE-SPACE AVERAGING [J].
GREEN, AW .
IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1993, 140 (06) :350-356
[4]  
GREEN AW, 1994, PEVD, V399, P694
[5]  
HU AP, 2000, IN PRESS 2000 IEEE I
[6]  
Skilling HH, 1961, ELECT ENG CIRCUITS