Correlation of the KISA% index and Scheimpflug tomography in 'normal', 'subclinical', 'keratoconus-suspect' and 'clinically manifest' keratoconus eyes

被引:41
作者
Steinberg, Johannes [1 ,2 ]
Aubke-Schultz, Silke [1 ]
Frings, Andreas [1 ]
Huelle, Jan
Druchkiv, Vasyl [1 ]
Richard, Gisbert [1 ]
Katz, Toam [1 ,2 ]
Linke, Stephan J. [1 ,2 ]
机构
[1] UKE Univ Med Ctr Hamburg Eppendorf, Dept Ophthalmol, Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Care Vis Germany, D-20246 Hamburg, Germany
关键词
classification system; keratoconus; KISA%; subclinical keratoconus; tomography; POSTERIOR CORNEAL ELEVATION; FORME-FRUSTE KERATOCONUS; ANTERIOR; THICKNESS; TOPOGRAPHY; DIAGNOSIS; PATIENT; VOLUME;
D O I
10.1111/aos.12590
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo analyse tomographic changes in eyes classified as normal', keratoconus-suspect' and clinically manifest keratoconus' based on the established KISA% definition of Rabinowitz and Rasheed and to develop the category of subclinical keratoconus eyes' to expand the classification into a subtopographic' range. MethodsTomographic and topographic analyses of 670 eyes performed with a rotating Scheimpflug imaging system (Pentacam((R)), Oculus Inc., Wetzlar, Germany) were retrospectively analysed. Based on the KISA% keratoconus classification system, eyes were assigned to a normal', keratoconus-suspect' or manifest keratoconus' group. In addition, a new group of subclinical keratoconus eyes' was analysed, comprising unsuspicious fellow eyes of patients with keratoconus. T-tests, Wilcoxon rank-sum test, receiver operating characteristics (ROC) and robust regression analyses were performed to correlate tomographic parameters with the increasing KISA% index. ResultsKISA%-grouped keratoconus eyes showed robust tomographic changes. By adding the subclinical group, although the concurrent topography was unchanged, we were able to demonstrate statistically significant changes for almost all tomographic parameters (parameters with highest sensitivity/specificity: ART_max, [0.69/0.69], BAD_D [0.66/0.66]). The highest coefficient of determination (R-2) with the KISA% index was demonstrated for Ele_f_max (R-2=0.70), Ele_f_TP (R-2=0.69), Ele_b_TP (R-2=0.69) and BAD_D (R-2=0.68). ConclusionWe recommend the use of the expanded KISA% index (eKISA% index) as the basis for the definition of keratoconus and normal groups in future keratoconus research projects.
引用
收藏
页码:e199 / e207
页数:9
相关论文
共 50 条
[31]   Comparative analysis of the relationship between anterior and posterior corneal shape analyzed by Scheimpflug photography in normal and keratoconus eyes [J].
Montalban, Raul ;
Alio, Jorge L. ;
Javaloy, Jaime ;
Pinero, David P. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (06) :1547-1555
[32]   Detection of Keratoconus in Clinically and Algorithmically Topographically Normal Fellow Eyes Using Epithelial Thickness Analysis [J].
Reinstein, Dan Z. ;
Archer, Timothy J. ;
Urs, Raksha ;
Gobbe, Marine ;
RoyChoudhury, Arindam ;
Silverman, Ronald H. .
JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (11) :736-U88
[33]   Application of a scheimpflug-based biomechanical analyser and tomography in the early detection of subclinical keratoconus in chinese patients [J].
Yan Liu ;
Yu Zhang ;
Yueguo Chen .
BMC Ophthalmology, 21
[34]   Application of a scheimpflug-based biomechanical analyser and tomography in the early detection of subclinical keratoconus in chinese patients [J].
Liu, Yan ;
Zhang, Yu ;
Chen, Yueguo .
BMC OPHTHALMOLOGY, 2021, 21 (01)
[35]   Meta-analysis of Pentacam vs. ultrasound pachymetry in central corneal thickness measurement in normal, post-LASIK or PRK, and keratoconic or keratoconus-suspect eyes [J].
Wu, Wenjing ;
Wang, Yan ;
Xu, Lulu .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (01) :91-99
[36]   Repeatability of Corneal Deformation Response Parameters by Dynamic Ultra High-speed Scheimpflug Imaging in Normal and Keratoconus Eyes [J].
Henriquez, Maria A. ;
Gomez, Isabel ;
Camino-Quezada, Maythe ;
Izquierdo, Luis, Jr. ;
Chauca, Jose ;
Binder, Perry S. .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2022, 48 (01) :14-19
[37]   Comparative analysis of the relationship between anterior and posterior corneal shape analyzed by Scheimpflug photography in normal and keratoconus eyes [J].
Raúl Montalbán ;
Jorge L. Alio ;
Jaime Javaloy ;
David P. Piñero .
Graefe's Archive for Clinical and Experimental Ophthalmology, 2013, 251 :1547-1555
[38]   Distribution Pattern of Total Corneal Thickness in Keratoconus versus Normal Eyes Using an Optical Coherence Tomography [J].
Hashemi, Hassan ;
Heidari, Zahra ;
Mohammadpour, Mehrdad ;
Momeni-Moghaddam, Hamed ;
Khabazkhoob, Mehdi .
JOURNAL OF CURRENT OPHTHALMOLOGY, 2022, 34 (02) :216-222
[39]   Comparison of corneal measurements in keratoconus eyes with two swept-source-optical coherence tomography devices and a Scheimpflug device [J].
Alexandra Bograd ;
Isabelle Himmel ;
Isabel B. Pfister ;
Theo G. Seiler ;
Beatrice E. Frueh ;
Christoph Tappeiner .
Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 :891-901
[40]   Morphological Features Among Gaussian, Sagittal, and Tangential Curvature Maps in Normal and Keratoconus Eyes Using Anterior Segment Optical Coherence Tomography [J].
Henriquez, Maria A. ;
Sacoto, Jose E. ;
Lopez, Josselyne ;
Chauca, Jose ;
Binder, Perry S. ;
Izquierdo, Luis .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (07) :283-291