Correlation of the KISA% index and Scheimpflug tomography in 'normal', 'subclinical', 'keratoconus-suspect' and 'clinically manifest' keratoconus eyes

被引:38
|
作者
Steinberg, Johannes [1 ,2 ]
Aubke-Schultz, Silke [1 ]
Frings, Andreas [1 ]
Huelle, Jan
Druchkiv, Vasyl [1 ]
Richard, Gisbert [1 ]
Katz, Toam [1 ,2 ]
Linke, Stephan J. [1 ,2 ]
机构
[1] UKE Univ Med Ctr Hamburg Eppendorf, Dept Ophthalmol, Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Care Vis Germany, D-20246 Hamburg, Germany
关键词
classification system; keratoconus; KISA%; subclinical keratoconus; tomography; POSTERIOR CORNEAL ELEVATION; FORME-FRUSTE KERATOCONUS; ANTERIOR; THICKNESS; TOPOGRAPHY; DIAGNOSIS; PATIENT; VOLUME;
D O I
10.1111/aos.12590
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo analyse tomographic changes in eyes classified as normal', keratoconus-suspect' and clinically manifest keratoconus' based on the established KISA% definition of Rabinowitz and Rasheed and to develop the category of subclinical keratoconus eyes' to expand the classification into a subtopographic' range. MethodsTomographic and topographic analyses of 670 eyes performed with a rotating Scheimpflug imaging system (Pentacam((R)), Oculus Inc., Wetzlar, Germany) were retrospectively analysed. Based on the KISA% keratoconus classification system, eyes were assigned to a normal', keratoconus-suspect' or manifest keratoconus' group. In addition, a new group of subclinical keratoconus eyes' was analysed, comprising unsuspicious fellow eyes of patients with keratoconus. T-tests, Wilcoxon rank-sum test, receiver operating characteristics (ROC) and robust regression analyses were performed to correlate tomographic parameters with the increasing KISA% index. ResultsKISA%-grouped keratoconus eyes showed robust tomographic changes. By adding the subclinical group, although the concurrent topography was unchanged, we were able to demonstrate statistically significant changes for almost all tomographic parameters (parameters with highest sensitivity/specificity: ART_max, [0.69/0.69], BAD_D [0.66/0.66]). The highest coefficient of determination (R-2) with the KISA% index was demonstrated for Ele_f_max (R-2=0.70), Ele_f_TP (R-2=0.69), Ele_b_TP (R-2=0.69) and BAD_D (R-2=0.68). ConclusionWe recommend the use of the expanded KISA% index (eKISA% index) as the basis for the definition of keratoconus and normal groups in future keratoconus research projects.
引用
收藏
页码:e199 / e207
页数:9
相关论文
共 50 条
  • [1] Evaluation of Scheimpflug imaging parameters in subclinical keratoconus, keratoconus, and normal eyes
    Ucakhan, Omur O.
    Cetinkor, Volkan
    Ozkan, Muhip
    Kanpolat, Ayfer
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06): : 1116 - 1124
  • [2] Evaluation of Scheimpflug Tomography Parameters in Subclinical Keratoconus, Clinical Keratoconus, and Normal Caucasian Eyes
    Huseynli, Samira
    Abdulaliyeva, Farah
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2018, 48 (03): : 99 - 108
  • [3] Aberrations and Topography in Normal, Keratoconus-Suspect, and Keratoconic Eyes
    Gordon-Shaag, Ariela
    Millodot, Michel
    Ifrah, Reut
    Shneor, Einat
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (04) : 411 - 418
  • [4] Misclassification of Eyes With Progressive Keratoconus Using the KISA% Index
    Hammoud, Bassel
    Dupps Jr, William J.
    Scarcelli, Giuliano
    Randleman, J. Bradley
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (09) : e614 - e624
  • [5] Evaluation of corneal elevation in eyes with subclinical keratoconus and keratoconus using Galilei double Scheimpflug analyzer
    Jafarinasab, Mohammad Reza
    Feizi, Sepehr
    Karimian, Farid
    Hasanpour, Hossein
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (03) : 377 - 384
  • [6] Pentacam Scheimpflug Tomography Findings in Topographically Normal Patients and Subclinical Keratoconus Cases
    Ruiseor Vazquez, Pablo R.
    David Galletti, Jonatan
    Minguez, Natalia
    Delrivo, Marianella
    Fuentes Bonthoux, Fernando
    Pfortner, Tomas
    Gaston Galletti, Jeremias
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (01) : 32 - 40
  • [7] Analysis of Scheimpflug Tomography Parameters for Detecting Subclinical Keratoconus in the Fellow Eyes of Patients with Unilateral Keratoconus in the Eastern Province of Saudi Arabia
    Al Somali, Abdulaziz
    Najmi, Hatim
    Alsawadi, Hend
    Alsawadi, Hassan
    Almalki, Assaf
    Alhamoud, Mustafa
    Alhatlan, Hatlan
    Alwohaibi, Nada
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 277 - 287
  • [8] Comparative evaluation of dual Scheimpflug imaging parameters in keratoconus, early keratoconus, and normal eyes
    Reddy, Jagadesh C.
    Rapuarto, Christopher J.
    Cater, Jacqueline R.
    Suri, Kunal
    Nagra, Parveen K.
    Hammersmith, Kristin M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (04): : 582 - 592
  • [9] Comparative Analysis of Anterior Segment Parameters in Normal and Keratoconus Eyes Generated by Scheimpflug Tomography
    Orucoglu, Faik
    Toker, Ebru
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [10] Corneal biomechanics in normal and subclinical keratoconus eyes
    Peyman, Alireza
    Sepahvand, Fatemeh
    Pourazizi, Mohsen
    Noorshargh, Pegah
    Forouhari, Ali
    BMC OPHTHALMOLOGY, 2023, 23 (01)