Correlation of the KISA% index and Scheimpflug tomography in 'normal', 'subclinical', 'keratoconus-suspect' and 'clinically manifest' keratoconus eyes

被引:41
作者
Steinberg, Johannes [1 ,2 ]
Aubke-Schultz, Silke [1 ]
Frings, Andreas [1 ]
Huelle, Jan
Druchkiv, Vasyl [1 ]
Richard, Gisbert [1 ]
Katz, Toam [1 ,2 ]
Linke, Stephan J. [1 ,2 ]
机构
[1] UKE Univ Med Ctr Hamburg Eppendorf, Dept Ophthalmol, Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Care Vis Germany, D-20246 Hamburg, Germany
关键词
classification system; keratoconus; KISA%; subclinical keratoconus; tomography; POSTERIOR CORNEAL ELEVATION; FORME-FRUSTE KERATOCONUS; ANTERIOR; THICKNESS; TOPOGRAPHY; DIAGNOSIS; PATIENT; VOLUME;
D O I
10.1111/aos.12590
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo analyse tomographic changes in eyes classified as normal', keratoconus-suspect' and clinically manifest keratoconus' based on the established KISA% definition of Rabinowitz and Rasheed and to develop the category of subclinical keratoconus eyes' to expand the classification into a subtopographic' range. MethodsTomographic and topographic analyses of 670 eyes performed with a rotating Scheimpflug imaging system (Pentacam((R)), Oculus Inc., Wetzlar, Germany) were retrospectively analysed. Based on the KISA% keratoconus classification system, eyes were assigned to a normal', keratoconus-suspect' or manifest keratoconus' group. In addition, a new group of subclinical keratoconus eyes' was analysed, comprising unsuspicious fellow eyes of patients with keratoconus. T-tests, Wilcoxon rank-sum test, receiver operating characteristics (ROC) and robust regression analyses were performed to correlate tomographic parameters with the increasing KISA% index. ResultsKISA%-grouped keratoconus eyes showed robust tomographic changes. By adding the subclinical group, although the concurrent topography was unchanged, we were able to demonstrate statistically significant changes for almost all tomographic parameters (parameters with highest sensitivity/specificity: ART_max, [0.69/0.69], BAD_D [0.66/0.66]). The highest coefficient of determination (R-2) with the KISA% index was demonstrated for Ele_f_max (R-2=0.70), Ele_f_TP (R-2=0.69), Ele_b_TP (R-2=0.69) and BAD_D (R-2=0.68). ConclusionWe recommend the use of the expanded KISA% index (eKISA% index) as the basis for the definition of keratoconus and normal groups in future keratoconus research projects.
引用
收藏
页码:e199 / e207
页数:9
相关论文
共 31 条
[1]   Biomechanical Responses of Healthy and Keratoconic Corneas Measured Using a Noncontact Scheimpflug-Based Tonometer [J].
Ali, Noor Q. ;
Patel, Dipika V. ;
McGhee, Charles N. J. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (06) :3651-3659
[2]   Customized photoastigmatic refractive keratectomy using combined topographic and refractive data for myopia and astigmatism in eyes with forme fruste and mild keratoconus [J].
Alpins, Noel ;
Stamatelatos, George .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (04) :591-602
[3]  
Ambrosio R., 2010, Highlights Ophthalmol, V38, P12
[4]   Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconus [J].
Ambrosio, Renato, Jr. ;
Alonso, Ruiz Simonato ;
Luz, Allan ;
Coca Velarde, Luis Guillermo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) :1851-1859
[5]   Novel Pachymetric Parameters Based on Corneal Tomography for Diagnosing Keratoconus [J].
Ambrosio, Renato, Jr. ;
Caiado, Ana Laura C. ;
Guerra, Frederico P. ;
Louzada, Ricardo ;
Roy, Abhijit Sinha ;
Luz, Allan ;
Dupps, William J. ;
Belin, Michael W. .
JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (10) :753-758
[6]  
AMSLER M, 1961, Wien Klin Wochenschr, V73, P842
[7]   FRUHDIAGNOSE UND MIKROSYMPTOME [J].
AMSLER, M .
OPHTHALMOLOGICA, 1965, 149 (05) :438-&
[8]   Use of a Support Vector Machine for Keratoconus and Subclinical Keratoconus Detection by Topographic and Tomographic Data [J].
Arbelaez, Maria Clara ;
Versaci, Francesco ;
Vestri, Gabriele ;
Barboni, Piero ;
Savini, Giacomo .
OPHTHALMOLOGY, 2012, 119 (11) :2231-2238
[9]   Statistical guidelines for the analysis of data obtained from one or both eyes [J].
Armstrong, Richard A. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2013, 33 (01) :7-14
[10]   Forme fruste anterior segment dysgenesis [J].
Banitt, M. R. ;
Romano, A. ;
Iragavarapu, S. ;
Budenz, D. L. ;
Lee, R. K. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (12) :1756-1764