Experimental validation of a thermophysical fluid model for use in a hyperthermia treatment planning system

被引:6
|
作者
Schooneveldt, Gerben [1 ]
Loke, Daan R. [1 ]
Zweije, Remko [1 ]
Helderman, Roxan F. C. P. A. [1 ,2 ]
Kok, H. Petra [1 ]
Crezee, Hans [1 ]
机构
[1] Univ Amsterdam, Dept Radiat Oncol, Amsterdam UMC, Amsterdam, Netherlands
[2] Univ Amsterdam, Ctr Expt & Mol & Mol Med CEMM, Lab Expt Oncol & Radiobiol LEXOR, Amsterdam UMC, Amsterdam, Netherlands
关键词
Fluid modelling; Treatment planning; Hyperthermia; BLADDER-CANCER; REGIONAL HYPERTHERMIA; MITOMYCIN-C; TRIAL; TEMPERATURE; CHEMOTHERAPY; RADIOTHERAPY; TISSUE;
D O I
10.1016/j.ijheatmasstransfer.2020.119495
中图分类号
O414.1 [热力学];
学科分类号
摘要
Accurate hyperthermia treatment planning, monitoring, and evaluation of temperatures in and near fluid volumes in the body requires realistic modelling of heat transport within fluids, which is currently not implemented in available treatment planning packages. Aim of this study is to assess the accuracy of a thermophysical fluid model, developed for treatment planning near fluid volumes. A cubic phantom with inner dimensions of (7 cm)(3) was filled with deionised water. The front, back, top and bottom walls of the cube consisted of PVC, the side walls of stainless steel. The left wall was kept at a constant temperature of 25 or 37 degrees C, the right wall at 1, 2, 5, 10, or 15 degrees C higher. Thermal probes mapped the temperature profile in the central vertical plane perpendicular to the cold and hot walls with a spatial resolution of 5-10 mm. The temperature distributions were compared to simulations using a finite volume-based thermophysical fluid model implementing the Boussinesq approximation to the Navier-Stokes equations, developed as an extension to our in-house developed hyperthermia treatment planning suite. The simulations were performed using three meshes at different resolutions. The fluid model predicts the temperature distribution accurately (random and systematic error <0.1 degrees C, at least 95% of absolute errors <0.2 degrees C) for hyperthermic temperature differences (<5 degrees C within the fluid volume). When the temperature differences reach 15 degrees C, the random and systematic errors increase to 0.3 degrees C and 0.1 degrees C, respectively, with absolute errors up to 1.1 degrees C. The thermophysical fluid model predicts temperature distributions in a convective fluid with sufficient accuracy for hyperthermia treatment planning in and near fluid regions. A mesh with a resolution of 0.25 cm combines accurate results with acceptable computation times. (C) 2020 The Authors. Published by Elsevier Ltd.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Commissioning and Validation of the First Monte Carlo Based Dose Calculation Algorithm Commercial Treatment Planning System in Mexico
    Larraga-Gutierrez, J. M.
    Garcia-Garduno, O. A.
    Galvan de la Cruz, O. O.
    Hernandez-Bojorquez, M.
    Ballesteros-Zebadua, P.
    ELEVENTH MEXICAN SYMPOSIUM ON MEDICAL PHYSICS, 2010, 1310 : 90 - +
  • [42] Effect of low-density heterogeneities in telecobalt therapy and validation of dose calculation algorithm of a treatment planning system
    Kumar, Anuj
    Sharma, Sunil Dutt
    Arya, A. K.
    Gupta, Surabhi
    Shrotriya, Deepak
    JOURNAL OF MEDICAL PHYSICS, 2011, 36 (04) : 198 - 204
  • [43] EXPERIMENTAL VALIDATION OF METHANOL CROSSOVER IN A THREE-DIMENSIONAL, TWO-FLUID MODEL OF A DIRECT METHANOL FUEL CELL
    Olesen, Anders C.
    Berning, Torsten
    Kaer, Soren Knudsen
    PROCEEDINGS OF THE ASME 10TH FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY CONFERENCE, 2012, 2012, : 397 - 408
  • [44] Experimental validation of stochastic microdosimetric kinetic model for multi-ion therapy treatment planning with helium-, carbon-, oxygen-, and neon-ion beams
    Inaniwa, Taku
    Suzuki, Masao
    Lee, Sung Hyun
    Mizushima, Kota
    Iwata, Yoshiyuki
    Kanematsu, Nobuyuki
    Shirai, Toshiyuki
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (04)
  • [45] Experimental verification of ion range calculation in a treatment planning system using a flat-panel detector
    Telsemeyer, Julia
    Ackermann, Benjamin
    Ecker, Swantje
    Jaekel, Oliver
    Martisikova, Maria
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (14) : 3737 - 3747
  • [46] Experimental and Monte Carlo evaluation of Eclipse treatment planning system for effects on dose distribution of the hip prostheses
    Catli, Serap
    Tanir, Gunes
    MEDICAL DOSIMETRY, 2013, 38 (03) : 332 - 336
  • [47] Loss of vacuum accident (LOVA): Comparison of computational fluid dynamics (CFD) flow velocities against experimental data for the model validation
    Bellecci, C.
    Gaudio, P.
    Lupelli, I.
    Malizia, A.
    Porfiri, M. T.
    Quaranta, R.
    Richetta, M.
    FUSION ENGINEERING AND DESIGN, 2011, 86 (4-5) : 330 - 340
  • [48] Evaluation of a model-based treatment planning system for dose computations in the kilovoltage energy range
    Alaei, P
    Gerbi, BJ
    Geise, RA
    MEDICAL PHYSICS, 2000, 27 (12) : 2821 - 2826
  • [49] Experimental evaluation of a GPU-based Monte Carlo dose calculation algorithm in the Monaco treatment planning system
    Paudel, Moti R.
    Kim, Anthony
    Sarfehnia, Arman
    Ahmad, Sayed B.
    Beachey, David J.
    Sahgal, Arjun
    Keller, Brian M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 230 - 241
  • [50] Finite difference thermal model of a latent heat storage system coupled with a photovoltaic device: Description and experimental validation
    Lo Brano, Valerio
    Ciulla, Giuseppina
    Piacentino, Antonio
    Cardona, Fabio
    RENEWABLE ENERGY, 2014, 68 : 181 - 193