Task-based statistical image reconstruction for high-quality cone-beam CT

被引:10
作者
Dang, Hao [1 ]
Stayman, J. Webster [1 ]
Xu, Jennifer [1 ]
Zbijewski, Wojciech [1 ]
Sisniega, Alejandro [1 ]
Mow, Michael [1 ]
Wang, Xiaohui [2 ]
Foos, David H. [2 ]
Aygun, Nafi [3 ]
Koliatsos, Vassilis E. [4 ]
Siewerdsen, Jeffrey H. [1 ,3 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Carestream Hlth, Rochester, NY 14608 USA
[3] Johns Hopkins Univ, Russell H Morgan Dept Radiol, Baltimore, MD 21205 USA
[4] Johns Hopkins Univ, Dept Neurol, Baltimore, MD 21205 USA
关键词
cone-beam computed tomography; regularization; imaging task; intracranial hemorrhage; statistical image reconstruction; image quality; SPATIAL-RESOLUTION PROPERTIES; COMPUTED-TOMOGRAPHY; ORDERED SUBSETS; OBSERVER PERFORMANCE; ARTIFACT-CORRECTION; LOCATION TASKS; VOLUMETRIC CT; NOISE; ARM; PROJECTION;
D O I
10.1088/1361-6560/aa90fd
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Task-based analysis of medical imaging performance underlies many ongoing efforts in the development of new imaging systems. In statistical image reconstruction, regularization is often formulated in terms to encourage smoothness and/or sharpness (e.g. a linear, quadratic, or Huber penalty) but without explicit formulation of the task. We propose an alternative regularization approach in which a spatially varying penalty is determined that maximizes task-based imaging performance at every location in a 3D image. We apply the method to model-based image reconstruction (MBIR-viz., penalized weighted least-squares, PWLS) in cone-beam CT (CBCT) of the head, focusing on the task of detecting a small, low-contrast intracranial hemorrhage (ICH), and we test the performance of the algorithm in the context of a recently developed CBCT prototype for point-of-care imaging of brain injury. Theoretical predictions of local spatial resolution and noise are computed via an optimization by which regularization (specifically, the quadratic penalty strength) is allowed to vary throughout the image to maximize local task-based detectability index (d'). Simulation studies and testbench experiments were performed using an anthropomorphic head phantom. Three PWLS implementations were tested: conventional (constant) penalty; a certainty-based penalty derived to enforce constant point-spread function, PSF; and the task-based penalty derived to maximize local detectability at each location. Conventional (constant) regularization exhibited a fairly strong degree of spatial variation in d', and the certainty-based method achieved uniform PSF, but each exhibited a reduction in detectability compared to the task-based method, which improved detectability up to similar to 15%. The improvement was strongest in areas of high attenuation (skull base), where the conventional and certainty-based methods tended to over-smooth the data. The task-driven reconstruction method presents a promising regularization method in MBIR by explicitly incorporating task-based imaging performance as the objective. The results demonstrate improved ICH conspicuity and support the development of high-quality CBCT systems.
引用
收藏
页码:8693 / 8719
页数:27
相关论文
共 76 条
[1]   Observer signal-to-noise ratios for the ML-EM algorithm. [J].
Abbey, CK ;
Barrett, HH ;
Wilson, DW .
IMAGE PERCEPTION - MEDICAL IMAGING 1996, 1996, 2712 :47-58
[2]  
[Anonymous], 1987, ALGORITHMS APPROXIMA
[3]   OBJECTIVE ASSESSMENT OF IMAGE QUALITY - EFFECTS OF QUANTUM NOISE AND OBJECT VARIABILITY [J].
BARRETT, HH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1990, 7 (07) :1266-1278
[4]   Signal detection and location-dependent noise in cone-beam computed tomography using the spatial definition of the Hotelling SNR [J].
Brunner, Claudia C. ;
Abboud, Samir F. ;
Hoeschen, Christoph ;
Kyprianou, Iacovos S. .
MEDICAL PHYSICS, 2012, 39 (06) :3214-3228
[5]   Dedicated Cone-Beam CT System for Extremity Imaging [J].
Carrino, John A. ;
Al Muhit, Abdullah ;
Zbijewski, Wojciech ;
Thawait, Gaurav K. ;
Stayman, J. Webster ;
Packard, Nathan ;
Senn, Robert ;
Yang, Dong ;
Foos, David H. ;
Yorkston, John ;
Siewerdsen, Jeffrey H. .
RADIOLOGY, 2014, 270 (03) :816-824
[6]   Prior Image Constrained Compressed Sensing (PICCS) [J].
Chen, Guang-Hong ;
Tang, Jie ;
Leng, Shuai .
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2008: THE NINTH CONFERENCE ON BIOMEDICAL THERMOACOUSTICS, OPTOACOUSTICS, AND ACOUSTIC-OPTICS, 2008, 6856
[7]   PRECONDITIONING METHODS FOR IMPROVED CONVERGENCE-RATES IN ITERATIVE RECONSTRUCTIONS [J].
CLINTHORNE, NH ;
PAN, TS ;
CHIAO, PC ;
ROGERS, WL ;
STAMOS, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (01) :78-83
[8]  
Dang H, 2016, Conf Proc Int Conf Image Form Xray Comput Tomogr, V2016, P557
[9]   Statistical reconstruction for cone-beam CT with a post-artifact-correction noise model: application to high-quality head imaging [J].
Dang, H. ;
Stayman, J. W. ;
Sisniega, A. ;
Xu, J. ;
Zbijewski, W. ;
Wang, X. ;
Foos, D. H. ;
Aygun, N. ;
Koliatsos, V. E. ;
Siewerdsen, J. H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (16) :6153-6175
[10]   dPIRPLE: a joint estimation framework for deformable registration and penalized-likelihood CT image reconstruction using prior images [J].
Dang, H. ;
Wang, A. S. ;
Sussman, Marc S. ;
Siewerdsen, J. H. ;
Stayman, J. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (17) :4799-4826