Effectiveness of Current Envelope Analysis to Detect Broken Rotor Bar and Inter Turn Faults in an Inverter Fed Induction Motor Drive.

被引:0
作者
Singh, Gurmeet [1 ]
Kumar, Ch. Anil [1 ]
Naikan, V. N. A. [1 ]
机构
[1] IIT Kharagpur, Ctr Reliabil Engn, Kharagpur, W Bengal, India
来源
PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON POWER AND ADVANCED CONTROL ENGINEERING (ICPACE) | 2015年
关键词
Envelope analysis; Hilbert transform; Broken rotor bar; Inter turn fault; Motor Fault detection; MCSA; CONDITION MONITORING TECHNIQUES;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In the present industrial scenario, machinery reliability and maintainability plays very important role in meeting the tight production schedules. In such systems, unexpected failures need to be minimized by effective fault diagnosis methods. Induction motors are used as prime movers in most industrial machinery. Therefore, effective fault diagnoses of induction motors are vital in achieving the minimal downtime and production targets. In this work, a comparative study between spectrum analysis of an Enveloped signal with that of traditionally used Fast Fourier Transformation (FFT) of motor current i.e. Motor Current Signature Analysis (MCSA) is performed. Nowadays, Inverter fed drives are commonly used for speed control operations. These drives generate noise and harmonics in the supply line which hinders the MCSA in fault detection. This paper investigate the effectiveness of MCSA and Current Envelope analysis for detection of broken rotor bar and inter turn fault in an inverter fed induction motor drive. A simulation based technique with addition of noise of low Signal to Noise Ratio (SNR) which serves as a replica of phase current in an inverter fed drives is followed.
引用
收藏
页码:191 / 194
页数:4
相关论文
共 14 条
[1]   A review of induction motors signature analysis as a medium for faults detection [J].
Benbouzid, ME .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (05) :984-993
[2]   SOME COMMENTARY ON THE CHOICE OF ROTOR BAR MATERIAL FOR INDUCTION-MOTORS [J].
DYMOND, JH ;
FINDLAY, RD .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1995, 10 (03) :425-430
[3]   Condition monitoring techniques for electrical equipment - A literature survey [J].
Han, Y ;
Song, YH .
IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (01) :4-13
[4]   Fault detection in induction motors using Hilbert and Wavelet transforms [J].
Jimenez, Guillermo A. ;
Munoz, Alfredo O. ;
Duarte-Mermoud, Manuel A. .
ELECTRICAL ENGINEERING, 2007, 89 (03) :205-220
[5]  
Kliman G.B., IEEE Trans, on EC, V3, P873
[6]  
Long D., 1998, 95105 MERS B YOUNG U
[7]  
Long D.G., 2004, Comments on Hilbert Transform Based Signal Analysis
[8]  
Mehala N., 2009, INT J CIRCUITS SYST, V3, P10
[9]   Rotor fault condition monitoring techniques for squirrel-cage induction machine-A review [J].
Mehrjou, Mohammad Rezazadeh ;
Mariun, Norman ;
Marhaban, Mohammad Hamiruce ;
Misron, Norhisam .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2011, 25 (08) :2827-2848
[10]   Practical Aspects of Mixed-Eccentricity Detection in PWM Voltage- Source-Inverter-Fed Induction Motors [J].
Morinigo-Sotelo, Daniel ;
Garcia-Escudero, L. A. ;
Duque-Perez, Oscar ;
Perez-Alonso, Marcelo .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (01) :252-262