Optimization of the method of measuring left ventricular end-diastolic diameter in cardiac magnetic resonance as a predictor of left ventricular enlargement

被引:3
|
作者
Gac, Pawel [1 ,2 ]
Waszczuk, Lukasz [1 ]
Kurcz, Jacek [1 ]
Poreba, Rafal [3 ]
机构
[1] Wroclaw Med Univ, Dept Gen & Intervent Radiol & Neuroradiol, Borowska 213, PL-50556 Wroclaw, Poland
[2] Wroclaw Med Univ, Dept Populat Hlth, Div Environm Hlth & Occupat Med, Mikulicza Radeckiego 7, PL-50368 Wroclaw, Poland
[3] Wroclaw Med Univ, Dept Internal Med Occupat Dis & Hypertens, Borowska 213, PL-50556 Wroclaw, Poland
关键词
EJECTION FRACTION; MASS; ECHOCARDIOGRAPHY; QUANTIFICATION; VARIABILITY; VOLUME; SIZE;
D O I
10.1038/s41598-022-12359-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The objective of the study was to optimize the method of measuring left ventricular end-diastolic diameter (LVEDD) in cardiac magnetic resonance (CMR) as a predictor of left ventricular end-diastolic volume (LVEDV). The study group consisted of 78 patients (age 55.28 +/- 17.18) who underwent 1.5 T CMR examination. LVEDD measurements in the short axis, in the long axis in the 2-chamber, 3-chamber and 4-chamber views were made by 2 radiologists. The repeatability of LVEDD measurements was assessed. The sensitivity and specificity of various methods of measuring LVEDD as a predictor of left ventricular enlargement (diagnosed based on LVEDV) were assessed. The correlation coefficients between LVEDD measurements made by researcher A and B were 0.98 for the long axis measurements in the 2-chamber and 3-chamber view, and 0.99 for measurements made in the short axis and in the long axis in the 4-chamber view. The lowest LVEDD measurements variability was recorded for the short axis measurements (RD 0.02, CV 1.38%), and the highest for the long axis measurements in the 3-chamber view (RD 0.04, CV 2.53%). In the male subgroup, the highest accuracy in predicting left ventricular enlargement was characterized by the criterion "LVEDD measured in the long axis in the 2-chamber view > 68.0 mm" (accuracy 94.1%). In the female subgroup, the highest accuracy in predicting left ventricular enlargement was achieved by the criterion "LVEDD measured in the short axis > 63.5 mm" (96.3%). In summary, the measurement made in the short axis should be considered the optimal method to LVEDD measure in CMR, considering the repeatability of measurements and the accuracy of left ventricular enlargement prediction.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Left Ventricular End-Diastolic Diameter Is an Independent Predictor of Mortality in Hemodialysis Patients
    Inoue, Tomoko
    Ogawa, Tetsuya
    Iwabuchi, Yuko
    Otsuka, Kuniaki
    Nitta, Kosaku
    THERAPEUTIC APHERESIS AND DIALYSIS, 2012, 16 (02) : 134 - 141
  • [2] Left Ventricular End-Diastolic Diameter and Cardiac Mortality in Duchenne Muscular Dystrophy
    Segawa, Kazuhiko
    Sugawara, Norio
    Maruo, Kazushi
    Kimura, Koichi
    Komaki, Hirofumi
    Takahashi, Yuji
    Sasaki, Masayuki
    NEUROPSYCHIATRIC DISEASE AND TREATMENT, 2020, 16 : 171 - 178
  • [3] Left ventricular end-diastolic pressure is associated with left atrial functional measures by echocardiography
    Olsen, Flemming Javier
    Mogelvang, Rasmus
    de Knegt, Martina Chantal
    Galatius, Soren
    Pedersen, Sune
    Modin, Daniel
    Ravnkilde, Kirstine
    Gislason, Gunnar
    Biering-Sorensen, Tor
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (11) : 3213 - 3221
  • [4] Continuous right ventricular end-diastolic volume in comparison with left ventricular end-diastolic area
    Della Rocca, Giorgio
    Costa, Maria Gabriella
    Coccia, Cecilia
    Pompei, Livia
    Salandin, Valeria
    Pierangelo, Di Marco
    Pietropaoli, Paolo
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2009, 26 (04) : 272 - 278
  • [5] Left ventricular end-diastolic pressure index predicts outcomes in patients with left ventricular diastolic dysfunction
    Xu, Liangjie
    Zhang, Fen
    Liang, Yi
    Fan, Tinpan
    Zhou, Cuicui
    Yuan, Wei
    POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ, 2023, 133 (05):
  • [6] Right-to-left ventricular end-diastolic diameter ratio and prediction of right ventricular failure with continuous-flow left ventricular assist devices
    Kukucka, Marian
    Stepanenko, Alexander
    Potapov, Evgenij
    Krabatsch, Thomas
    Redlin, Mathias
    Mladenow, Alexander
    Kuppe, Hermann
    Hetzer, Roland
    Habazettl, Helmut
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (01) : 64 - 69
  • [7] Automated Segmentation of Routine Clinical Cardiac Magnetic Resonance Imaging for Assessment of Left Ventricular Diastolic Dysfunction
    Kawaji, Keigo
    Codella, Noel C. F.
    Prince, Martin R.
    Chu, Christopher W.
    Shakoor, Aqsa
    LaBounty, Troy M.
    Min, James K.
    Swaminathan, Rajesh V.
    Devereux, Richard B.
    Wang, Yi
    Weinsaft, Jonathan W.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2009, 2 (06) : 476 - 484
  • [8] Correlation of left atrial strain with left ventricular end-diastolic pressure in patients with normal left ventricular ejection fraction
    Fan, Jia-Li
    Su, Bo
    Zhao, Xin
    Zhou, Bing-Yuan
    Ma, Chang-Sheng
    Wang, Hai-Peng
    Hu, Sheng-Da
    Zhou, Ya-Feng
    Ju, Yi-Jiao
    Wang, Ming-Han
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (09) : 1659 - 1666
  • [9] Correlation between Left Ventricular End-diastolic Pressure and Peak Left Atrial Wall Strain during Left Ventricular Systole
    Wakami, Kazuaki
    Ohte, Nobuyuki
    Asada, Kaoru
    Fukuta, Hidekatsu
    Goto, Toshihiko
    Mukai, Seiji
    Narita, Hitomi
    Kimura, Genjiro
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (07) : 847 - 851
  • [10] Left ventricular end-diastolic pressure is associated with left atrial functional measures by echocardiography
    Flemming Javier Olsen
    Rasmus Møgelvang
    Martina Chantal de Knegt
    Søren Galatius
    Sune Pedersen
    Daniel Modin
    Kirstine Ravnkilde
    Gunnar Gislason
    Tor Biering-Sørensen
    The International Journal of Cardiovascular Imaging, 2021, 37 : 3213 - 3221