Gel-integrated microelectrode arrays for direct voltammetric measurements of heavy metals in natural waters and other complex media

被引:118
作者
Belmont-Hébert, C
Tercier, ML
Buffle, J
Fiaccabrino, GC
de Rooij, NF
Koudelka-Hep, M
机构
[1] CABE, Dept Inorgan Analyt & Appl Chem, CH-1211 Geneva 4, Switzerland
[2] Univ Neuchatel, Inst Microtechnol, CH-2007 Neuchatel, Switzerland
关键词
D O I
10.1021/ac971194c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A voltammetric sensor developed for in situ trace metal analysis in natural waters is presented. It consists of an array of 100 mercury-plated, iridium-based microdisk electrodes, coated with a 300-600-mu m-thick 1.5% agarose gel membrane. This membrane acts as a dialysis membrane by allowing the diffusion of metal ions and complexes and by hindering the diffusion of colloids and macromolecules. Chronoamperometry and square wave anodic stripping voltammetry (SWASV) have been used to characterize the diffusion of hexacyanoferrate(III), lead, and cadmium in the agarose gel. For these species, the diffusion coefficients have been found to be half of the diffusion coefficient in free solution, and the time necessary for complete equilibration with the test solution varied with the gel thickness in accordance with the theory and can be lowered to 5 min for a gel thickness of 300 mu m. The same techniques have been used to demonstrate the efficiency of the membrane against fouling and convection. Pressures in the range 1-600 bar have been found to have no effect on the sensor response. In contrast, variations in temperature in the range 4-22 degrees C considerably affected diffusion and charge-transfer kinetics, the resulting currents obeying a simple Arrhenius equation. These results confirm the suitability of the voltammetric sensor for in situ analysis of heavy metals in natural waters.
引用
收藏
页码:2949 / 2956
页数:8
相关论文
共 27 条
[1]   EFFECT OF MODEL ORGANIC-COMPOUNDS ON POTENTIOMETRIC STRIPPING ANALYSIS USING A CELLULOSE-ACETATE MEMBRANE-COVERED ELECTRODE [J].
ALDSTADT, JH ;
DEWALD, HD .
ANALYTICAL CHEMISTRY, 1993, 65 (07) :922-926
[2]   SPACE VARIABLES WELL FITTED FOR THE STUDY OF STEADY-STATE AND NEAR-STEADY-STATE DIFFUSION AT A MICRODISK [J].
AMATORE, CA ;
FOSSET, B .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 328 (1-2) :21-32
[3]   Mercury-plated iridium-based microelectrode arrays for trace metals detection by voltammetry: Optimum conditions and reliability [J].
Belmont, C ;
Tercier, ML ;
Buffle, J ;
Fiaccabrino, GC ;
KoudelkaHep, M .
ANALYTICA CHIMICA ACTA, 1996, 329 (03) :203-214
[4]   TRACE-METAL ANALYSIS BY ANODIC-STRIPPING VOLTAMMETRY - EFFECT OF SORPTION BY NATURAL AND MODEL ORGANIC-COMPOUNDS [J].
BREZONIK, PL ;
BRAUNER, PA ;
STUMM, W .
WATER RESEARCH, 1976, 10 (07) :605-612
[5]   VOLTAMMETRIC STUDY OF HUMIC AND FULVIC SUBSTANCES .5. INTERPRETATION OF METAL-ION COMPLEXATION MEASURED BY ANODIC-STRIPPING VOLTAMMETRIC METHODS [J].
BUFFLE, J ;
VUILLEUMIER, JJ ;
TERCIER, ML ;
PARTHASARATHY, N .
SCIENCE OF THE TOTAL ENVIRONMENT, 1987, 60 :75-96
[6]  
Buffle J., 1988, Complexation Reactions in Aquatic Systems
[7]  
Campbel PGC, 1995, IUPAC SERIES ANAL PH, V3, P45
[8]   ON THE TEMPERATURE-DEPENDENCE OF POLAROGRAPHIC CURRENTS [J].
CHEN, HY ;
NEEB, R .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 319 (03) :240-247
[9]   COMPARATIVE-STUDY OF POLYMER-COATED MERCURY FILM ELECTRODES FOR VOLTAMMETRIC ANALYSIS OF LEAD AND CADMIUM IN THE PRESENCE OF SURFACTANTS [J].
DAM, MER ;
THOMSEN, KN ;
PICKUP, PG ;
SCHRODER, KH .
ELECTROANALYSIS, 1995, 7 (01) :70-78
[10]   Hot-wire electrodes: Voltammetry above the boiling point [J].
Grundler, P ;
Kirbs, A ;
Zerihun, T .
ANALYST, 1996, 121 (12) :1805-1810