Uncemented custom femoral components in hip arthroplasty A prospective clinical study of 191 hips followed for at least 7 years

被引:18
作者
Benum, Pal [1 ]
Aamodt, Arild
机构
[1] Norwegian Univ Sci & Technol, St Olavs Univ Hosp, Dept Orthopaed, N-7034 Trondheim, Norway
关键词
MATCHED-PAIR ANALYSIS; YOUNG-PATIENTS; STEMS; PROSTHESIS; FRACTURES; 15-YEAR; DESIGN; TERM;
D O I
10.3109/17453674.2010.501748
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose We have developed an individually designed, uncemented femoral component for achievement of improved strain distribution and fixation to the bone, to make uncemented stems more applicable in femurs of abnormal size and shape, and to improve the joint mechanics. Here we describe the design of the implant and present the results of a prospective clinical study with at least 7 years of follow-up. Patients and methods The prostheses are produced by CAD-CAM technique. The design of the stem is based on CT information, and the neck design is based on the surgeon's planning of the center of rotation, femoral head offset, and leg length correction. The first-generation stem produced before 2001 had a proximal HA coating and a sand-blasted distal part that was down-scaled to avoid contact with compact bone. The second-generation stem had a porous coating beneath the HA layer and the distal part of the stem was polished. The implant was used in 762 hips (614 patients) from 1995 until 2009. 191 of these hips were followed for 7 years and 83 others were followed for 10 years, and these hips are included in the present study. Mean age at surgery was 48 (20-65) years. Congenital dysplasia of the hip was the reason for osteoarthritis in 46% and 57% of the hips in respective groups. Merle d'Aubigne score was recorded in 152 and 75 hips in the two groups. Prostheses followed for 10 years, and almost all in the 7-year group, were first-generation stems. Results The 7- and 10-year cumulative revision rates were 1.1% and 2.4%, respectively, with stem revision for any reason as endpoint. The clinical results were similar at 7 and 10 years, with Merle d'Aubigne scores of 17. Intraoperative trochanteric fissures occurred in 2 of the 191 operations (1.0%); both healed after wiring. In hips followed for 7 years, 2 periprosthetic fractures occurred; exchange of the stem was necessary in both. One additional fracture occurred between 7 and 10 years, and it was treated successfully with osteosynthesis. The rate of dislocation was 1.6% and 2.4%, respectively. There was no radiographic loosening at follow-up. Interpretation Use of a custom femoral stem gives a reliable fixation and promising medium-term clinical results in femurs of normal and abnormal shape and dimension. The individual design, which enables optimized joint mechanics, gives a low risk of mechanical complications.
引用
收藏
页码:427 / 435
页数:9
相关论文
共 31 条
[1]   Changes in proximal femoral strain after insertion of uncemented standard and customised femoral stems [J].
Aamodt, A ;
Lund-Larsen, J ;
Eine, J ;
Andersen, E ;
Benum, P ;
Husby, OS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06) :921-929
[2]  
Aamodt A, 2002, Hip Int, V12, P263, DOI 10.5301/HIP.2008.4719
[3]   Determination of the Hounsfield value for CT-based design of custom femoral stems [J].
Aamodt, A ;
Kvistad, KA ;
Andersen, E ;
Lund-Larsen, J ;
Eine, J ;
Benum, P ;
Husby, OS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (01) :143-147
[4]   Custom stems for femoral deformity in patients less than 40 years of age 70 hips followed for an average of 14 years [J].
Akbar, Michael ;
Aldinger, Guenther ;
Krahmer, Knut ;
Bruckner, Thomas ;
Aldinger, Peter R. .
ACTA ORTHOPAEDICA, 2009, 80 (04) :420-425
[5]  
Aldinger G, 1988, Ital J Orthop Traumatol, V14, P429
[6]  
Argenson J, 2004, 15 YEARS CLIN EXPERI, P139
[7]  
BARGAR WL, 1989, CLIN ORTHOP RELAT R, P73
[8]   Hydroxyapatite-coated femoral components - 15-year minimum followup [J].
Capello, William N. ;
D'Antonio, James A. ;
Jaffe, William L. ;
Geesink, Rudolph G. ;
Manley, Michael T. ;
Feinberg, Judy R. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (453) :75-80
[9]   Risk factors for periprosthetic fractures of the hip: A survivorship analysis [J].
Cook, R. E. ;
Jenkins, P. J. ;
Walmsley, P. J. ;
Patton, J. T. ;
Robinson, C. M. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (07) :1652-1656
[10]   FUNCTIONAL RESULTS OF HIP ARTHROPLASTY WITH ACRYLIC PROSTHESIS [J].
DAUBIGNE, RM ;
POSTEL, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (03) :451-475