Right Coronary MR Angiography at 7 T: A Direct Quantitative and Qualitative Comparison with 3 T in Young Healthy Volunteers

被引:36
作者
van Elderen, Saskia G. C. [1 ]
Versluis, Maarten J. [1 ]
Westenberg, Jos J. M. [1 ]
Agarwal, Harsh [2 ]
Smith, Nadine B. [1 ]
Stuber, Matthias [2 ,3 ,4 ]
de Roos, Albert [1 ]
Webb, Andrew G. [1 ]
机构
[1] Leiden Univ, Dept Radiol, Med Ctr, NL-2333 ZA Leiden, Netherlands
[2] Johns Hopkins Univ, Dept Elect & Comp Engn, Sch Med, Baltimore, MD 21218 USA
[3] CHU Vaudois, Dept Radiol, Ctr Biomed Imaging, CH-1011 Lausanne, Switzerland
[4] Univ Lausanne, Lausanne, Switzerland
基金
美国国家卫生研究院;
关键词
1.5; TESLA;
D O I
10.1148/radiol.100615
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To objectively compare quantitative parameters related to image quality attained at coronary magnetic resonance (MR) angiography of the right coronary artery (RCA) performed at 7 T and 3 T. Materials and Methods: Institutional review board approval was obtained, and volunteers provided signed informed consent. Ten healthy adult volunteers (mean age +/- standard deviation, 25 years +/- 4; seven men, three women) underwent navigator-gated three-dimensional MR angiography of the RCA at 7 T and 3 T. For 7 T, a custom-built quadrature radiofrequency transmit-receive surface coil was used. At 3 T, a commercial body radiofrequency transmit coil and a cardiac coil array for signal reception were used. Segmented k-space gradient-echo imaging with spectrally selective adiabatic fat suppression was performed, and imaging parameters were similar at both field strengths. Contrast-to-noise ratio between blood and epicardial fat; signal-to-noise ratio of the blood pool; RCA vessel sharpness, diameter, and length; and navigator efficiency were quantified at both field strengths and compared by using a Mann-Whitney U test. Results: The contrast-to-noise ratio between blood and epicardial fat was significantly improved at 7 T when compared with that at 3 T (87 +/- 34 versus 52 +/- 13; P = .01). Signal-to-noise ratio of the blood pool was increased at 7 T (109 6 47 versus 67 +/- 19; P = .02). Vessel sharpness obtained at 7 T was also higher (58% +/- 9 versus 50% +/- 5; P = .04). At the same time, RCA vessel diameter and length and navigator efficiency showed no significant field strength-dependent difference. Conclusion: In our quantitative and qualitative study comparing in vivo human imaging of the RCA at 7 T and 3 T in young healthy volunteers, parameters related to image quality attained at 7 T equal or surpass those from 3 T. (C) RSNA, 2010
引用
收藏
页码:254 / 259
页数:6
相关论文
共 19 条
  • [1] Three-dimensional breathhold SSFP coronary MRA: A comparison between 1.5T and 3.OT
    Bi, XM
    Deshpande, V
    Simonetti, O
    Laub, G
    Li, DB
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (02) : 206 - 212
  • [2] Coronary arteries at 3.0 T: Contrast-enhanced magnetization-prepared three-dimensional breathhold MR angiography
    Bi, XM
    Li, DB
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (02) : 133 - 139
  • [3] Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA
    Botnar, RM
    Stuber, M
    Danias, PG
    Kissinger, KV
    Manning, WJ
    [J]. CIRCULATION, 1999, 99 (24) : 3139 - 3148
  • [4] Soap-bubble visualization and quantitative analysis of 3D coronary magnetic resonance angiograms
    Etienne, A
    Botnar, RM
    van Muiswinkel, AMC
    Boesiger, P
    Manning, WJ
    Stuber, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) : 658 - 666
  • [5] Fischer SE, 1999, MAGN RESON MED, V42, P361, DOI 10.1002/(SICI)1522-2594(199908)42:2<361::AID-MRM18>3.0.CO
  • [6] 2-9
  • [7] Feasibility of Cardiac Gating Free of Interference With Electro-Magnetic Fields at 1.5 Tesla, 3.0 Tesla and 7.0 Tesla Using an MR-Stethoscope
    Frauenrath, Tobias
    Hezel, Fabian
    Heinrichs, Uwe
    Kozerke, Sebastian
    Utting, Jane F.
    Kob, Malte
    Butenweg, Christoph
    Boesiger, Peter
    Niendorf, Thoralf
    [J]. INVESTIGATIVE RADIOLOGY, 2009, 44 (09) : 539 - 547
  • [8] KATO S, J AM COLL C IN PRESS
  • [9] MADERWALD S, 2009, P 17 M INT SOC MAGN, P821
  • [10] Diagnostic Performance of Coronary Angiography by 64-Row CT
    Miller, Julie M.
    Rochitte, Carlos E.
    Dewey, Marc
    Arbab-Zadeh, Armin
    Niinuma, Hiroyuki
    Gottlieb, Ilan
    Paul, Narinder
    Clouse, Melvin E.
    Shapiro, Edward P.
    Hoe, John
    Lardo, Albert C.
    Bush, David E.
    de Roos, Albert
    Cox, Christopher
    Brinker, Jeffery
    Lima, Joao A. C.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2008, 359 (22) : 2324 - 2336