Shear-slip behaviour of prefabricated composite shear stud connectors in composite bridges

被引:28
作者
Gao, Yanmei [1 ]
Li, Chengjun [2 ]
Wang, Xuefei [1 ]
Zhou, Zhixiang [3 ]
Fan, Liang [1 ]
Heng, Junlin [3 ,4 ]
机构
[1] Chongqing Jiaotong Univ, Sch Civil Engn, Dept Bridge Engn, Chongqing 400074, Peoples R China
[2] Sichuan Vocat & Tech Coll Commun, Dept Rd & Bridge Engn, Chengdu 611130, Peoples R China
[3] Shenzhen Univ, Dept Civil Engn, Coll Civil & Transportat Engn, Shenzhen 518060, Peoples R China
[4] Delft Univ Technol, Sch Civil Engn & Geosci, Dept Engn Struct, NL-2628 CN Delft, Netherlands
基金
中国国家自然科学基金;
关键词
Prefabricated composite shear studs connector; Push-out test; High-resolution finite element analysis; Shear-slip behaviour; Load-transfer mechanism; Prefabricated steel-concrete composite bridge; PERFORMANCE;
D O I
10.1016/j.engstruct.2021.112148
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper has investigated the shear-slip behaviour of an innovative prefabricated composite shear stud (PCSS) connector and its application in the prefabricated steel-concrete composite bridges. A series of push-out tests are carried out on a total of 12 specimens, including 6 PCSS specimens and 6 conventional shear stud (CSS) specimens. Further comparison has been carried out between the test result and the data available from the literature. Based on the test, a high-resolution finite element (FE) analysis has been performed to reveal the load transfer mechanism of the PCSS connector at the component-level. After that, an advanced FE model has been established and validated by a full-scale test of the prefabricated composite bridge using the PCSS. With the FE model, the load-slip behaviour and slip distribution are investigated in details. The result highlights the enhanced shear capacity and ductility of the PCSS specimens compared with the CSS specimens, as well as the feasibility of PCSS connectors in composite bridges. Meanwhile, it is further revealed by the detailed investigation that the enhancement could be attributed to the lateral constraint on the concrete by the vertical steel plate in the PCSS. Besides, it is also found that the load-slip behaviour of composite bridges using the PCSS is influenced by the cracking at the seam between deck blocks. Consequently, abrupt changes can be found in the load-slip curve once the cracking occurs, which differs from the traditional composite bridges.
引用
收藏
页数:16
相关论文
共 45 条
[1]   Static and Fatigue Tests of Steel-Precast Composite Beam Specimens with Through-Bolt Shear Connectors [J].
Balkos, Kyle D. ;
Sjaarda, Matthew ;
West, Jeffrey S. ;
Walbridge, Scott .
JOURNAL OF BRIDGE ENGINEERING, 2019, 24 (05)
[2]  
CEN European Committee for Standardisation, EUR 3 DES STEEL ST 1
[3]   Control of Creep and Shrinkage Effects in Steel Concrete Composite Bridges with Precast Decks [J].
Chaudhary, Sandeep ;
Pendharkar, Umesh ;
Nagpal, Ashok Kumar .
JOURNAL OF BRIDGE ENGINEERING, 2009, 14 (05) :336-345
[4]   Behaviour of steel-precast composite girders with through-bolt shear connectors under static loading [J].
Chen, Y. -T. ;
Zhao, Y. ;
West, J. S. ;
Walbridge, S. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 103 :168-178
[5]  
[陈一馨 Chen Yixin], 2012, [桥梁建设, Bridge Construction], V42, P63
[6]  
Dassault Syst`emes, AB SOFTW
[7]   Modelling of headed stud in steel-precast composite beams [J].
El-Lobody, E ;
Lam, D .
STEEL & COMPOSITE STRUCTURES, 2002, 2 (05) :355-378
[8]  
FHWA, 2009, FHWAIF09010
[9]   Cracking of a prefabricated steel truss-concrete composite beam with pre-embedded shear studs under hogging moment [J].
Gao, Yanmei ;
Zhou, Zhixiang ;
Liu, Dong ;
Wang, Yinhui .
STEEL AND COMPOSITE STRUCTURES, 2016, 21 (05) :981-997
[10]  
Guo ZH., 2003, PRINCIPLES ANAL REIN