Test-retest reliability of step counts with the ActivPAL™ device in common daily activities

被引:66
作者
Dahlgren, Gunilla [2 ]
Carlsson, Daniel [2 ]
Moorhead, Anne [1 ]
Hager-Ross, Charlotte [2 ]
McDonough, Suzanne M. [1 ]
机构
[1] Univ Ulster, Hlth & Rehabil Sci Res Inst, Sch Hlth Sci, Newtownabbey BT37 0QB, Antrim, North Ireland
[2] Umea Univ, Dept Community Med & Rehabil, SE-90187 Umea, Sweden
关键词
Accelerometer; Physical activity; Reliability; ActivPAL; ACTIVITY MONITOR; REHABILITATION; VALIDITY;
D O I
10.1016/j.gaitpost.2010.06.022
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The ActivPAL device is a well-established physical activity monitor for assessment of physical activity. Aim: To investigate test-retest reliability of step counts and establish minimal detectable changes (MDC) in step count to account for intra device error over time in various physical activities. Methods: Healthy participants (n = 24, age range, 19-28 years) performed activities on two occasions, 1 week apart, in a laboratory setting; self-paced floor walking, treadmill walking at three different speeds (3.2 km/h, 4.5 km/h and 4.5 km/h with incline), treadmill jogging (8.0 km/h), stair walking and cycling on an exercise bike at three speeds (45 rpm, 60 rpm and 75 rpm). Relative reliability was calculated using intraclass correlation coefficient (ICC) and Spearman correlation. Absolute reliability was assessed using standard error of measurement (SEM) and coefficient of repeatability (CR). Results: The ActivPAL showed high to very high relative reliability for treadmill walking at all speeds and stair walking, while self-paced normal floor walking showed moderate reliability. The absolute reliability was the best for treadmill walking activities, slightly increased for self-paced walking, followed by stair walking and jogging. The use of activity monitors during cycling has been questioned and our results confirm a low absolute and relative reliability. MDC values varied according to the type of activity e.g. treadmill walking 4.5 km/h (10 steps), walking on the floor (45 steps). Data loss in this study (10-13%) was higher than previously reported. Conclusions: The ActivPAL is reliable for treadmill walking, jogging and self-paced walking. MCD varies according to the activity and should be considered when establishing true change over time. Crown Copyright (C) 2010 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:386 / 390
页数:5
相关论文
共 14 条
  • [1] Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine
    Atkinson, G
    Nevill, AM
    [J]. SPORTS MEDICINE, 1998, 26 (04) : 217 - 238
  • [2] Busse M. E., 2009, Journal of Medical Engineering & Technology, V33, P33, DOI 10.1080/03091900701682606
  • [3] Godfrey A., 2006, MED ENG PHYS
  • [4] The validation of a novel activity monitor in the measurement of posture and motion during everyday activities
    Grant, P. M.
    Ryan, C. G.
    Tigbe, W. W.
    Granat, M. H.
    [J]. BRITISH JOURNAL OF SPORTS MEDICINE, 2006, 40 (12) : 992 - 997
  • [5] Interpreting change scores of tests and measures used in physical therapy
    Haley, SM
    Fragala-Pinkham, MA
    [J]. PHYSICAL THERAPY, 2006, 86 (05): : 735 - 743
  • [6] Paraspinal muscle EMG fatigue testing with two methods in healthy volunteers. Reliability in the context of clinical applications
    Koumantakis, GA
    Arnall, F
    Cooper, RG
    Oldham, JA
    [J]. CLINICAL BIOMECHANICS, 2001, 16 (03) : 263 - 266
  • [7] How to assess the reliability of measurements in rehabilitation
    Lexell, JE
    Downham, DY
    [J]. AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2005, 84 (09) : 719 - 723
  • [8] MADDOCKS M, 2008, BRIT J SPORTS MED
  • [9] Munro BH., 1997, STAT METHODS HLTH CA, VThird
  • [10] PORTNEY LG, 2007, FDN CLIN RES APPL PR, V12