Design and Application of a Four-Channel Transmit/Receive Surface Coil for Functional Cardiac Imaging at 7T

被引:47
作者
Dieringer, Matthias A. [1 ,2 ,3 ]
Renz, Wolfgang [1 ,4 ]
Lindel, Tomasz [1 ,5 ]
Seifert, Frank [1 ,5 ]
Frauenrath, Tobias [1 ]
von Knobelsdorff-Brenkenhoff, Florian [1 ,2 ,3 ]
Waiczies, Helmar [1 ,5 ]
Hoffmann, Werner [1 ,5 ]
Rieger, Jan [1 ]
Pfeiffer, Harald [1 ,5 ]
Ittermann, Bernd [1 ,5 ]
Schulz-Menger, Jeanette [1 ,2 ,3 ]
Niendorf, Thoralf [1 ,2 ]
机构
[1] Max Delbruck Ctr Mol Med, Berlin Ultrahigh Field Facil, D-13125 Berlin, Germany
[2] Charite, ECRC, D-13353 Berlin, Germany
[3] HELIOS Clin Berlin Buch, Clin Cardiol & Nephrol, Berlin, Germany
[4] Siemens Healthcare, Erlangen, Germany
[5] Phys Tech Bundesanstalt, Berlin, Germany
关键词
ultrahigh field cardiovascular MRI; RF coil design; left ventricular function; 7.0; Tesla; 7T cardiac imaging;
D O I
10.1002/jmri.22451
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T. Materials and Methods: A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former, specific absorption rate (SAR) simulations were performed and a B-1(+) calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 x 1 x 2.5 mm(3). Results: Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S-21) was measured to be > 18 dB between neighboring loops, > 20 dB for opposite loops, and > 30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the B-1(+) calibration approach. Conclusion: A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated.
引用
收藏
页码:736 / 741
页数:6
相关论文
共 20 条
[1]   Quantitative Assessment of Left Ventricular Function in Humans at 7 T [J].
Brandts, Anne ;
Westenberg, Jos J. M. ;
Versluis, Maarten J. ;
Kroft, Lucia J. M. ;
Smith, Nadine B. ;
Webb, Andrew G. ;
de Roos, Albert .
MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (05) :1472-1478
[2]   B1+ Interferometry for the Calibration of RF Transmitter Arrays [J].
Brunner, David O. ;
Pruessmann, Klaas P. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (06) :1480-1488
[3]   The Virtual Family-development of surface-based anatomical models of two adults and two children for dosimetric simulations [J].
Christ, Andreas ;
Kainz, Wolfgang ;
Hahn, Eckhart G. ;
Honegger, Katharina ;
Zefferer, Marcel ;
Neufeld, Esra ;
Rascher, Wolfgang ;
Janka, Rolf ;
Bautz, Werner ;
Chen, Ji ;
Kiefer, Berthold ;
Schmitt, Peter ;
Hollenbach, Hans-Peter ;
Shen, Jianxiang ;
Oberle, Michael ;
Szczerba, Dominik ;
Kam, Anthony ;
Guag, Joshua W. ;
Kuster, Niels .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (02) :N23-N38
[4]  
DUAN Q, 2010, P 18 ANN M ISMRM STO
[5]   Acoustic method for synchronization of magnetic resonance imaging (MRI) [J].
Frauenrath, Tobias ;
Niendorf, Thoralf ;
Kob, Malte .
ACTA ACUSTICA UNITED WITH ACUSTICA, 2008, 94 (01) :148-155
[6]   Feasibility of Cardiac Gating Free of Interference With Electro-Magnetic Fields at 1.5 Tesla, 3.0 Tesla and 7.0 Tesla Using an MR-Stethoscope [J].
Frauenrath, Tobias ;
Hezel, Fabian ;
Heinrichs, Uwe ;
Kozerke, Sebastian ;
Utting, Jane F. ;
Kob, Malte ;
Butenweg, Christoph ;
Boesiger, Peter ;
Niendorf, Thoralf .
INVESTIGATIVE RADIOLOGY, 2009, 44 (09) :539-547
[7]  
Ishimori Yoshiyuki, 2007, Magn Reson Med Sci, V6, P67, DOI 10.2463/mrms.6.67
[8]  
Maderwald S, 2009, P 17 ANN M ISMRM HON, DOI 822
[9]   Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Pane report [J].
Pennell, DJ ;
Sechtem, UP ;
Higgins, CB ;
Manning, WJ ;
Pohost, GM ;
Rademakers, FE ;
van Rossum, AC ;
Shaw, LJ ;
Yucel, EK .
EUROPEAN HEART JOURNAL, 2004, 25 (21) :1940-1965
[10]   Patient safety concept for multichannel transmit coils [J].
Seifert, Frank ;
Wuebbeler, Gerd ;
Junge, Sven ;
Ittermann, Bernd ;
Rinneberg, Herbert .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (05) :1315-1321